Determination of chromium in water and urine by reaction cell inductively coupled plasma mass spectrometry

被引:61
作者
Chang, YL [1 ]
Jiang, SJ [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung 80424, Taiwan
关键词
D O I
10.1039/b107107f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An inductively coupled plasma mass spectrometry (ICP-MS) instrument equipped with a dynamic reaction cell (DRC) was used for the determination of chromium in water and urine samples. The effect of the operating conditions of the DRC system was studied to get the best signal-to-noise ratio. The potentially interfering (ArC+)-Ar-40-C-12, (ClOH+)-Cl-35-O-16, (SO)-S-34-O-18, (ArCH+)-Ar-40-C-12 and (ClO+)-Cl-37-O-16 ions at the chromium masses m/z 52 and 53 were reduced in intensity by approximately 2-3 orders of magnitude by using 1.0 ml min(-1) NH3 as reaction cell gas in the DRC while a q value of 0.6 was used. The limits of detection for Cr-52 and Cr-53 were 0.015 and 0.024 ng ml(-1) Cr, respectively. This method was applied to determine Cr in NRCC SLRS-3 Riverine Water reference sample, NIST SRM 1643d Trace Elements in Water, NIST SRM 2670 Urine reference sample and several water and urine samples collected locally. The external calibration method and isotope dilution method were used for the determination of Cr in selected samples. The results for the reference samples agreed satisfactorily with the reference values. Results for other samples analyzed by different quantitation methods agreed satisfactorily. Precision between sample replicates was better than 20% for most of the determinations.
引用
收藏
页码:1434 / 1438
页数:5
相关论文
共 24 条
[1]   A dynamic reaction cell for inductively coupled plasma mass spectrometry (ICP-DRC-MS) - Part 1. The rf-field energy contribution in thermodynamics of ion-molecule reactions [J].
Baranov, VI ;
Tanner, SD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (08) :1133-1142
[2]   DETERMINATION OF URANIUM IN ENVIRONMENTAL-SAMPLES USING INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BOOMER, DW ;
POWELL, MJ .
ANALYTICAL CHEMISTRY, 1987, 59 (23) :2810-2813
[3]  
CHANG YL, 2001, IN PRESS J ANAL AT S, V16
[4]   Attenuation of metal oxide ions in inductively coupled plasma mass spectrometry with hydrogen in a hexapole collision cell [J].
Du, ZY ;
Houk, RS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (04) :383-388
[5]   INFLUENCE OF INSTRUMENT PARAMETERS ON NONSPECTROSCOPIC INTERFERENCES IN INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY [J].
GREGOIRE, DC .
APPLIED SPECTROSCOPY, 1987, 41 (05) :897-903
[6]  
Houk R., 1986, ANAL CHEM, V58, P97
[7]   Determination of copper, cadmium and lead in biological samples by isotope dilution inductively coupled plasma mass spectrometry after on-line pre-treatment by anodic stripping voltammetry [J].
Hwang, TJ ;
Jiang, SJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (05) :353-357
[8]   Influence of sample pre-treatment on the determination of trace elements in urine by quadrupole and magnetic sector field inductively coupled plasma mass spectrometry [J].
Krachler, M ;
Alimonti, A ;
Petrucci, F ;
Forastiere, F ;
Caroli, S .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (08) :701-705
[9]   Comparison of different nebulisers and chromatographic techniques for the speciation of selenium in nutritional commercial supplements by hexapole collision and reaction cell ICP-MS [J].
Marchante-Gayón, JM ;
Thomas, C ;
Feldmann, I ;
Jakubowski, N .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (09) :1093-1102
[10]   Flow analysis of micro amounts of chromium(III) and (VI) in natural water by solid phase spectrophotometry using diphenylcarbazide [J].
Matsuoka, S ;
Tennichi, Y ;
Takehara, K ;
Yoshimura, K .
ANALYST, 1999, 124 (05) :787-791