On the road to high-resolution 3D molecular imaging

被引:14
作者
Delcorte, Arnaud [1 ]
机构
[1] Catholic Univ Louvain, PCPM Lab, Louvain, Belgium
关键词
ToF-SIMS; SIMS imaging; Depth-profiling; Molecular ion; Chemical analysis; Surface characterization; Nanotechnology; Cell; Organics; Polymers;
D O I
10.1016/j.apsusc.2008.05.111
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This contribution reviews the state-of-the-art in the domains of molecular imaging and depth profiling, the two methodological platforms required for 3D molecular imaging by secondary ion mass spectrometric (SIMS). Using molecular dynamics calculations, it also describes some of the mechanisms that make cluster projectiles such as C-60 so different for organic sample analysis. The discussion addresses issues that deserve proper attention on the way to 3D molecular imaging in SIMS, such as ultimate lateral resolution, limited molecular yields, chemical effects and damage, and highlights solutions currently in embryo in the many research teams concerned by 3D molecular imaging. (C) 2008 Elsevier B. V. All rights reserved.
引用
收藏
页码:954 / 958
页数:5
相关论文
共 47 条
[1]   Metal-assisted secondary ion mass spectrometry: Influence of Ag and Au deposition on molecular ion yields [J].
Adriaensen, L ;
Vangaever, F ;
Gijbels, R .
ANALYTICAL CHEMISTRY, 2004, 76 (22) :6777-6785
[2]   High-resolution MALDI imaging mass spectrometry allows localization of peptide distributions at cellular length scales in pituitary tissue sections [J].
Altelaar, A. F. Maarten ;
Taban, Ioana M. ;
McDonnell, Liam A. ;
Verhaert, Peter D. E. M. ;
de Lange, Robert P. J. ;
Adan, Roger A. H. ;
Mooi, Wolter J. ;
Heeren, Ron M. A. ;
Piersma, Sander R. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 260 (2-3) :203-211
[3]   Gold-enhanced biomolecular surface imaging of cells and tissue by SIMS and MALDI mass spectrometry [J].
Altelaar, AFM ;
Klinkert, I ;
Jalink, K ;
de Lange, RPJ ;
Adan, RAH ;
Heeren, RMA ;
Piersma, SR .
ANALYTICAL CHEMISTRY, 2006, 78 (03) :734-742
[4]   Properties of C84 and C24H12 molecular ion sources for routine TOF-SIMS analysis [J].
Biddulph, Gregory X. ;
Piwowar, Alan M. ;
Fletcher, John S. ;
Lockyer, Nicholas P. ;
Vickerman, John C. .
ANALYTICAL CHEMISTRY, 2007, 79 (19) :7259-7266
[5]   Depth profiling of taxol-loaded poly(styrene-b-isobutylene-b-styrene) using Ga+ and C60+ ion beams [J].
Braun, R. M. ;
Cheng, J. ;
Parsonage, E. E. ;
Moeller, J. ;
Winograd, N. .
APPLIED SURFACE SCIENCE, 2006, 252 (19) :6615-6618
[6]   Biological tissue imaging with time-of-flight secondary ion mass spectrometry and cluster ion sources [J].
Brunelle, A ;
Touboul, D ;
Laprévote, O .
JOURNAL OF MASS SPECTROMETRY, 2005, 40 (08) :985-999
[7]   Instrument design and characterization for high resolution MALDI-MS imaging of tissue sections [J].
Chaurand, Pierre ;
Schriver, Kenneth E. ;
Caprioli, Richard M. .
JOURNAL OF MASS SPECTROMETRY, 2007, 42 (04) :476-489
[8]   Molecular depth profiling with cluster ion beams [J].
Cheng, J ;
Wucher, A ;
Winograd, N .
JOURNAL OF PHYSICAL CHEMISTRY B, 2006, 110 (16) :8329-8336
[9]   Molecular depth profiling of multi-layer systems with cluster ion sources [J].
Cheng, Juan ;
Winograd, Nicholas .
APPLIED SURFACE SCIENCE, 2006, 252 (19) :6498-6501
[10]   Attempts for molecular depth profiling directly on a rat brain tissue section using fullerene and bismuth cluster ion beams [J].
Debois, Delphine ;
Brunelle, Alain ;
Laprevote, Olivier .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 260 (2-3) :115-120