Precision spectroscopy of metastable hydrogen and antihydrogen with a Lamb-shift polarimeter

被引:0
|
作者
Engels, R. [1 ]
Grigoryev, K. [1 ]
Mikirtytchyants, M. [1 ]
Schieck, H. Paetz Gen [2 ]
Rathmann, F. [1 ]
Schug, G. [1 ]
Stroeher, H. [1 ]
Vasilyev, A. [3 ]
Westig, M. [4 ]
机构
[1] FZ Julich, Inst Kernphys, D-52425 Julich, Germany
[2] Univ Cologne, Inst Kernphys, D-50937 Cologne, Germany
[3] St Petersburg Nucl Phys Inst, Gatchina 188350, Russia
[4] Univ Cologne, Inst Phys 1, D-50937 Cologne, Germany
来源
HYPERFINE INTERACTIONS | 2009年 / 193卷 / 1-3期
关键词
Lamb shift; Hyperfine Splitting; Spinfilter; HYPERFINE-STRUCTURE; NUCLEAR-SPIN; STATE;
D O I
10.1007/s10751-009-0021-x
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A spinfilter, the most important component of a Lamb-shift polarimeter, can be used to produce a beam of metastable hydrogen (deuterium) atoms in one hyperfine state (alpha 1, alpha 2 and together with the Sona transition beta 3). As function of a magnetic field separated transitions between the 2S(1/2) metastable hyperfine states seem to be observable as well as single transitions into the short-lived 2P(1/2) and 2P(3/2) states. The Breit-Rabi diagrams for these states can be measured with good precision. Furthermore, the hyperfine splittings and the Lamb shift can be observed as well. Application of this method to anti-hydrogen atoms are suggested.
引用
收藏
页码:341 / 347
页数:7
相关论文
共 50 条
  • [21] OBSERVATION OF LAMB-SHIFT IN N = 4 STATE OF HYDROGEN
    BROWN, R
    PIPKIN, FM
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (04): : 488 - &
  • [22] MEASUREMENT OF THE LAMB-SHIFT IN HYDROGEN-LIKE OXYGEN
    CURNUTTE, B
    COCKE, CL
    DUBOIS, RD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 202 (1-2): : 119 - 121
  • [23] The size of the proton From the Lamb-shift in muonic hydrogen
    Nebel, T.
    Antognini, A.
    Amaro, F. D.
    Biraben, F.
    Cardoso, J. M. R.
    Covita, D. S.
    Dax, A.
    Dhawan, S.
    Fernandes, L. M. P.
    Giesen, A.
    Graf, T.
    Haensch, T. W.
    Indelicato, P.
    Julien, L.
    Kao, C. -Y.
    Knowles, P.
    Kottmann, F.
    Le Bigot, E.
    Liu, Y. -W.
    Lopes, J. A. M.
    Ludhova, L.
    Monteiro, C. M. B.
    Mulhauser, F.
    Nez, F.
    Rabinowitz, P.
    dos Santos, J. M. F.
    Schaller, L. A.
    Schuhmann, K.
    Schwob, C.
    Taqqu, D.
    Veloso, J. F. C. A.
    Pohl, R.
    HYPERFINE INTERACTIONS, 2012, 212 (1-3): : 185 - 194
  • [24] AN IMPROVED LAMB-SHIFT SOURCE FOR POLARIZED NEGATIVE HYDROGEN IONS
    MEINER, H
    MICHEL, G
    DARDEN, SE
    CORRIGAN, K
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1968, 13 (04): : 557 - &
  • [25] AN IMPROVED LAMB-SHIFT SOURCE FOR POLARISED NEGATIVE HYDROGEN IONS
    MEINER, H
    MICHEL, G
    CORRIGAN, K
    NUCLEAR INSTRUMENTS & METHODS, 1968, 62 (02): : 203 - &
  • [26] IMPROVED LAMB-SHIFT EXPERIMENTS
    ROTHENBE.MS
    PHYSICS TODAY, 1971, 24 (08) : 20 - &
  • [27] Polarization measurement of a pulsed H-/D- ion beam with a Lamb-shift Polarimeter
    Puetz, Simon J.
    Engels, R.
    Gebel, R.
    Grigoryev, K.
    Valdau, Y.
    19TH WORKSHOP ON POLARIZED SOURCES, TARGETS AND POLARIMETRY, 2023,
  • [28] PRECISION DETERMINATION OF THE LAMB SHIFT IN HYDROGEN
    NEWTON, G
    ANDREWS, DA
    UNSWORTH, PJ
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1979, 290 (1373): : 374 - 404
  • [29] Measuring the antihydrogen Lamb shift with a relativistic antihydrogen beam
    Blanford, G
    Gollwitzer, K
    Mandelkern, M
    Schultz, J
    Takei, G
    Zioulas, G
    Christian, DC
    Munger, CT
    PHYSICAL REVIEW D, 1998, 57 (11): : 6649 - 6655
  • [30] LAMB-SHIFT SOURCES - RAPPORTEURS REPORT
    CLAUSNITZER, G