High performances of 18F-fluorodeoxyglucose PET-CT in cardiac implantable device infections: A study of 40 patients

被引:44
|
作者
Tlili, Ghoufrane [1 ]
Amroui, Sana [2 ]
Mesguich, Charles [1 ]
Riviere, Annalisa [1 ]
Bordachar, Pierre [2 ]
Hindie, Elif [1 ]
Bordenave, Laurence [1 ,3 ]
机构
[1] CHU Bordeaux, Nucl Med Serv, Bordeaux, France
[2] CHU Bordeaux, Serv Cardiol, Bordeaux, France
[3] CHU Bordeaux, CIC, Bordeaux, France
关键词
F-18-FDG; infection; pacemaker; PET-CT; EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY; DIAGNOSIS; PLAY;
D O I
10.1007/s12350-015-0067-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cardiovascular implantable electronic devices (CIED) infections are life-threatening complications. The diagnosis can be difficult to establish. Our purpose is to evaluate the diagnostic value of F-18-FDG PET. Forty patients who received work-up for suspected CIED infection were retrospectively included (group 1) and compared with 40 controls (group 2); CIED patients were referred for oncologic PET. PET-CT data were blindly assessed. Interpretation was based on visual analysis of both attenuation-corrected and non-corrected images and a semi-quantitative analysis was performed. The gold standard was bacteriological data of explanted devices or clinical follow-up for at least 1 year. Infection was present in 18 out of 40 patients of group 1. Sensitivity, specificity, positive predictive value, and negative predictive value of PET-CT were 83%, 95%, 94%, and 88%, respectively. Accuracy was 90%. PET-CT revealed the presence of additional pathological hypermetabolic foci in 28% of cases. PET-CT was negative at implanted devices in all patients of group 2. F-18-FDG PET-CT is helpful in the work-up of suspected CIED infections. It is a potential tool to make the accurate diagnosis of CIED infection and to assess the extent of infection. The promising results in this indication need to be validated in a prospective multicenter study.
引用
收藏
页码:787 / 798
页数:12
相关论文
共 50 条
  • [1] High performances of 18F-fluorodeoxyglucose PET-CT in cardiac implantable device infections: A study of 40 patients
    Ghoufrane Tlili
    Sana Amroui
    Charles Mesguich
    Annalisa Rivière
    Pierre Bordachar
    Elif Hindié
    Laurence Bordenave
    Journal of Nuclear Cardiology, 2015, 22 : 787 - 798
  • [2] Accuracy of 18F-FDG PET/CT in patients with the suspicion of cardiac implantable electronic device infections
    Jeronimo, Adrian
    Olmos, Carmen
    Vilacosta, Isidre
    Ortega-Candil, Aida
    Rodriguez-Rey, Cristina
    Perez-Castejon, Maria Jesus
    Fernandez-Perez, Cristina
    Perez-Garcia, Carlos Nicolas
    Garcia-Arribas, Daniel
    Ferrera, Carlos
    Carreras, Jose Luis
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (02) : 594 - 608
  • [3] Reappraisal of [18F]FDG-PET/CT for diagnosis and management of cardiac implantable electronic device infections
    Hernandez-Meneses, Marta
    Perissinotti, Andres
    Paez-Martinez, Silvia
    Llopis, Jaume
    Dahl, Anders
    Sandoval, Elena
    Falces, Carlos
    Ambrosioni, Juan
    Marco, Francesc
    Cuervo, Guillermo
    Bosch, Jordi
    Tolosana, Jose M.
    Fuster, David
    Miro, Jose M.
    REVISTA ESPANOLA DE CARDIOLOGIA, 2023, 76 (12): : 970 - 979
  • [4] Accuracy of 18F-FDG PET/CT in patients with the suspicion of cardiac implantable electronic device infections
    Adrián Jerónimo
    Carmen Olmos
    Isidre Vilacosta
    Aida Ortega-Candil
    Cristina Rodríguez-Rey
    María Jesús Pérez-Castejón
    Cristina Fernández-Pérez
    Carlos Nicolás Pérez-García
    Daniel García-Arribas
    Carlos Ferrera
    José Luis Carreras
    Journal of Nuclear Cardiology, 2022, 29 : 594 - 608
  • [5] Impact of 18F-fluorodeoxyglucose PET/CT in the management of patients with plasma cell disorders
    Shachar, Ben
    Prica, Anca
    Anconina, Reut
    Hawsawy, Asmaa
    MacCrostie, Pamela
    Langer, Deanna
    Metser, Ur
    NUCLEAR MEDICINE COMMUNICATIONS, 2020, 41 (01) : 34 - 39
  • [6] Innovations in Imaging: 18F-Fluorodeoxyglucose PET/CT for Assessment of Cardiovascular Infection and Inflammation
    Trivedi, Siddharth J.
    Bourque, Jamieson M.
    CURRENT CARDIOLOGY REPORTS, 2024, 26 (12) : 1413 - 1425
  • [7] Usefulness of 18F-FDG PET/CT in Patients with Cardiac Implantable Electronic Device Suspected of Late Infection
    Rubini, Giuseppe
    Ferrari, Cristina
    Carretta, Domenico
    Santacroce, Luigi
    Ruta, Rossella
    Iuele, Francesca
    Lavelli, Valentina
    Merenda, Nunzio
    D'Agostino, Carlo
    Sardaro, Angela
    Asabella, Artor Niccoli
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (07) : 1 - 13
  • [8] Prognostic value of 18F-fluorodeoxyglucose PET-CT score at baseline on the therapeutic response to prednisone in patients with polymyalgia rheumatica
    Giraud, Nicolas
    Prati, Clement
    Wendling, Daniel
    Verhoeven, Frank
    JOINT BONE SPINE, 2021, 88 (01)
  • [9] Lung hot spot as pitfall in PET-CT interpretation: focal lung uptake of 18F-fluorodeoxyglucose
    Redal Pena, M. C.
    Pena Pardo, F. J.
    Munoz Iglesias, J.
    Crespo-Jara, A.
    Rebollo, J.
    Brugarolas Masllorens, A.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR, 2011, 30 (04): : 248 - 250
  • [10] Quantitative analysis of myocardial 18F-fluorodeoxyglucose uptake by PET/CT for detection of cardiac sarcoidosis
    Yokoyama, Rami
    Miyagawa, Masao
    Okayama, Hideki
    Inoue, Takeshi
    Miki, Hitoshi
    Ogimoto, Akiyoshi
    Higaki, Jitsuo
    Mochizuki, Teruhito
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 195 : 180 - 187