High resolution air-vented ionization chamber array for QA of VMAT and stereotactic treatments

被引:0
|
作者
Togno, M. [1 ,2 ,3 ]
Menichelli, D. [1 ]
Vogel, C. [1 ]
Celi, J. C. [1 ]
Wilkens, J. J. [2 ,3 ]
McGlade, J. [4 ]
Mooij, R. [4 ]
Olszanski, A. [4 ]
Solberg, T. [4 ]
机构
[1] IBA Dosimetry GmbH, Phys & Innovat Dept, Schwarzenbruck, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Dept Radiat Oncol, Munich, Germany
[3] Tech Univ Munich, Dept Phys, Munich, Germany
[4] Perelman Ctr Adv Med, Dept Radiat Oncol, Philadelphia, PA USA
关键词
D O I
10.1016/S0167-8140(16)32747-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
EP-1497
引用
收藏
页码:S691 / S692
页数:2
相关论文
共 50 条
  • [1] Influence of ambient humidity on the current delivered by air-vented ionization chambers revisited
    Poirier, Aurelie
    Douysset, Guilhem
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (19): : 4995 - 5006
  • [2] Numerical modeling of air-vented parallel plate ionization chambers for ultra-high dose rate applications
    Paz-Martin, Jose
    Schueller, Andreas
    Bourgouin, Alexandra
    Gonzalez-Castano, Diego M.
    Gomez-Fernandez, Nicolas
    Pardo-Montero, Juan
    Gomez, Faustino
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 103 : 147 - 156
  • [3] IMRT/VMAT QA Employing a High Resolution Measurement Array: Initial Experience and Limitations
    Gainey, M.
    Saum, R.
    Rothe, T.
    Knobe, S.
    Luebke, J.
    Kuechler, S.
    Wiehle, R.
    Kollefrath, M.
    Bruggmoser, G.
    MEDICAL PHYSICS, 2015, 42 (06) : 3445 - 3445
  • [4] Impact of the LINAC Repetition Rate On a High-Resolution Liquid Ionization Chamber Array for Patient-Specific QA
    Wang, S.
    Driewer, J.
    Zheng, D.
    Lei, Y.
    Zhang, Q.
    Zhu, X.
    Li, S.
    Enke, C.
    Xu, B.
    Zhou, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3440 - 3440
  • [5] Liquid filled ionization chamber 2D-array for patient specific QA for stereotactic treatment at CyberKnife®
    Magaddino, V.
    Vallet, V.
    Patin, D.
    Schopfer, M.
    Moeckli, R.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 836 - 836
  • [6] An Ionization Chamber Array with High Spatial Resolution for External Beam Radiotherapy
    Togno, M.
    Wilkens, J.
    Menichelli, D.
    MEDICAL PHYSICS, 2014, 41 (06) : 321 - 321
  • [7] Implementation of an ionization chamber array for linear accelerator monthly dosimetry QA
    Taneja, Sameer
    Barbee, David L.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (09):
  • [8] Characterization of a 2D ionization chamber array for IMRT QA
    Shtraus, N.
    Curran, B.
    Moran, J.
    Litzenberg, D.
    MEDICAL PHYSICS, 2007, 34 (06) : 2600 - 2600
  • [9] High-resolution Diode array vs film for QA of trigeminal neuralgia treatments with Cyberknife
    Sevillano, David
    Garcia-Fuentes, Juan David
    Colmenares, Rafael
    Camara, Miguel
    Capuz, Belen
    Moris, Rafael
    Galiano, Pablo
    Williamson, Sandra
    Chillida, Ruben
    Rodriguez-Manzaneque, Carlos
    Jose Bejar, Maria
    Prieto, Daniel
    Garcia-Vicente, Feliciano
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3299 - S3301
  • [10] Can An Ionization-Chamber Array Be Used for QA of Proton SBRT Beams?
    Stanforth, A.
    Diamond, Z.
    Sabouri, P.
    Zhu, M.
    Zhou, J.
    Slopsema, R.
    MEDICAL PHYSICS, 2021, 48 (06)