Diagnostic validity of ultrasonography in carpal tunnel syndrome

被引:0
作者
Bueno-Gracia, Elena [1 ]
Haddad-Garay, Maria [2 ]
Tricas-Moreno, Jose M. [1 ]
Fanlo-Mazas, Pablo [1 ]
Malo-Urries, Miguel [1 ]
Estebanez-de-Miguel, Elena [1 ]
Hidalgo-Garcia, Cesar [1 ]
Ruiz de Escudero-Zapico, Alazne [1 ]
机构
[1] Univ Zaragoza, Dept Fisiatria & Enfermeria, E-50009 Zaragoza, Spain
[2] Hosp Univ Miguel Servet, Serv Neurofisiol Clin, Zaragoza, Spain
关键词
Carpal tunnel syndrome; Diagnosis; Diagnostic validity; Electroneuromyogram; Neuropathy; Ultrasonography; NEURODYNAMIC TEST 1; GENERAL-POPULATION; ULTRASOUND; METAANALYSIS; ACCURACY; SURGERY; RATIO;
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Introduction. Ultrasonography has emerged as an alternative tool for diagnosing peripheral neuropathies, such as carpal tunnel syndrome (CTS). Yet, data are still lacking as regards the diagnostic validity of the different ultrasonography measurements for detecting CTS in clinical settings. Aims. To determine the diagnostic validity of ultrasound measurements of the cross-sectional area of the median nerve in the wrist (CSA-M) and of the ratio of the area of the median nerve between the wrist and the forearm (R-WF) in the diagnosis of CTS, using electroneuromyography (ENG) as the reference technique. Patients and methods. Ultrasound measurements were performed on 59 subjects (100 wrists) who were referred to have an ENG due to suspected CTS. The examiners that performed the ultrasonography scan did not know the results of the ENG. The cut-off points were later calculated by means of ROC curves for each of the measurements (CSA-M and R-WF) and their diagnostic validity was analysed. Results. With a cut-off point of 9.15 mm(2), CSA-M measurement obtained a sensitivity of 75.81%, a specificity of 74.29%, a positive likelihood ratio of 2.95 and a negative likelihood ratio of 0.33. For the R-WF measurement and a cut-off point of 1.56, the values for sensitivity, specificity, and positive and negative likelihood ratios were 70.97%, 71.43%, 2.48 and 0.4, respectively. Conclusions. Both the CSA-M and R-WF appear to be useful measures in the diagnosis of CTS, taking the ENG as a reference test.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [41] Ultrasonography in Carpal Tunnel Syndrome. A Case Report
    Bila, M.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2013, 80 (05) : 356 - 359
  • [42] Ultrasonography of the Median Nerve in the Carpal Tunnel Syndrome Diagnosis
    Pertea, Mihaela
    Ursu, S.
    Ciobanu, P.
    Grosu, Oxana Madalina
    Tudor, R.
    Sirbu, P. D.
    2019 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2019,
  • [43] Ultrasonography for the diagnosis of carpal tunnel syndrome: an umbrella review
    Lin, Ting-Yu
    Chang, Ke-Vin
    Wu, Wei-Ting
    Ozcakar, Levent
    JOURNAL OF NEUROLOGY, 2022, 269 (09) : 4663 - 4675
  • [44] Application of 3-Dimensional Ultrasonography in Assessing Carpal Tunnel Syndrome
    Pyun, Sung Bum
    Kang, Chang Ho
    Yoon, Joon Shik
    Kwon, Hee Kyu
    Kim, Jung Hyuk
    Chung, Kyoo Byung
    Oh, Yu Whan
    JOURNAL OF ULTRASOUND IN MEDICINE, 2011, 30 (01) : 3 - 10
  • [45] Evaluation of high-frequency ultrasonography for diagnosis of carpal tunnel syndrome
    Dixit, Ayush
    Pande, Sonjjay
    Khandelwal, Namrata
    Agarwal, Pawan
    Sharma, Dhananjaya
    Dhakar, Jag Mohan Singh
    TROPICAL DOCTOR, 2024, 54 (04) : 331 - 334
  • [46] What is the diagnostic value of ultrasonography compared to physical evaluation in patients with idiopathic carpal tunnel syndrome?
    Naranjo, A.
    Ojeda, S.
    Mendoza, D.
    Francisco, F.
    Quevedo, J. C.
    Erausquin, C.
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2007, 25 (06) : 853 - 859
  • [47] Diagnostic Accuracy of Ultrasound Parameters in Carpal Tunnel Syndrome: Additional Criteria for Diagnosis
    Gonzalez-Suarez, Consuelo B.
    Fidel, Belinda C.
    Cabrera, Jan Tyrone C.
    Dela Cruz, Fatima C.
    Gesmundo, Maria Veronica T.
    Regala, Carina Fatima G.
    Saratan, Rochelle
    Suarez, Charidy G.
    Grimmer, Karen
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (11) : 3043 - 3052
  • [48] The diagnostic value of ultrasound compared with nerve conduction velocity in carpal tunnel syndrome
    Azami, Ahad
    Maleki, Nasrollah
    Anari, Hassan
    Iranparvar Alamdari, Manouchehr
    Kalantarhormozi, Mohammadreza
    Tavosi, Zahra
    INTERNATIONAL JOURNAL OF RHEUMATIC DISEASES, 2014, 17 (06) : 612 - 620
  • [49] Evaluation of diagnostic procedures for carpal tunnel syndrome
    Tuck, NR
    Simper, D
    Schliesser, J
    Cramer, GD
    JNMS-JOURNAL OF THE NEUROMUSCULOSKELETAL SYSTEM, 2000, 8 (01): : 1 - 9
  • [50] The use of diagnostic ultrasound in carpal tunnel syndrome
    Wiesler, ER
    Chloros, GD
    Cartwright, MS
    Smith, BP
    Rushing, J
    Walker, FO
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (05): : 726 - 732