Bioresorbable vascular scaffolds versus conventional drug-eluting stents across time: a meta-analysis of randomised controlled trials

被引:5
作者
Jackson-Smith, Elliot [1 ]
Zioupos, Stephanie [1 ]
Banerjee, Prithwish [1 ,2 ,3 ]
机构
[1] Univ Warwick, Warwick Med Sch, Coventry, England
[2] Coventry Univ, Centre Sports Exercise & Life Sci CSELS, Fac Hlth & Life Sci, Coventry, England
[3] Univ Hosp Coventry & Warwickshire, Dept Cardiol, Coventry, England
来源
OPEN HEART | 2022年 / 9卷 / 02期
关键词
CORONARY-ARTERY-DISEASE; ELEVATION MYOCARDIAL-INFARCTION; 2-YEAR CLINICAL-OUTCOMES; STENOSIS ABSORB II; METALLIC STENT; PERCUTANEOUS CORONARY; FOLLOW-UP; EVEROLIMUS; POLYMER; INTERVENTION;
D O I
10.1136/openhrt-2022-002107
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Bioresorbable vascular scaffolds (BVS) were designed to reduce the rate of late adverse events observed in conventional drug-eluting stents (DES) by dissolving once they have restored lasting patency. Objectives Compare the safety and efficacy of BVS versus DES in patients receiving percutaneous coronary intervention for coronary artery disease across a complete range of randomised controlled trial (RCT) follow-up intervals. Methods A systematic review and meta-analysis was performed using Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. MEDLINE, EMBASE and Web of Science were searched from inception through 5 January 2022 for RCTs comparing the clinical outcomes of BVS versus DES. The primary safety outcome was stent/scaffold thrombosis (ST), and the primary efficacy outcome was target lesion failure (TLF: composite of cardiac death, target vessel myocardial infarction (TVMI) and ischaemia-driven target lesion revascularisation (ID-TLR)). Secondary outcomes were patient-oriented composite endpoint (combining all-death, all-MI and all-revascularisation), its individual components and those of TLF. Studies were appraised using Cochrane's Risk of Bias tool and meta-analysis was performed using RevMan V.5.4. Results 11 919 patients were randomised to receive either BVS (n=6438) or DES (n=5481) across 17 trials (differing follow-up intervals from 3 months to 5 years). BVS demonstrated increased risk of ST across all timepoints (peaking at 2 years with risk ratio (RR): 3.47; 95% CI 1.80 to 6.70; p=0.0002). Similarly, they showed increased risk of TLF (peaking at 3 years, RR: 1.35; 95% CI 1.07 to 1.70; p=0.01) resulting from high rates of TVMI and ID-TLR. Though improvements were observed after device dissolution (5-year follow-up), these were non-significant. All other outcomes were statistically equivalent. Applicability to all BVS is limited by 91% of the BVS group receiving Abbott's Absorb. Conclusion This meta-analysis demonstrates that current BVS are inferior to contemporary DES throughout the first 5 years at minimum.
引用
收藏
页数:12
相关论文
共 50 条
[21]   Drug-Eluting Stents Versus Coronary Artery Bypass Grafts for Left Main Coronary Disease: A Meta-Analysis and Review of Randomised Controlled Trials [J].
Moore, Peter ;
Burrage, Matthew ;
Garrahy, Paul ;
Lim, Richard ;
McCann, Andrew ;
Camuglia, Anthony .
HEART LUNG AND CIRCULATION, 2018, 27 (12) :1437-1445
[22]   Polymer-free drug-eluting stents versus permanent polymer drug-eluting stents An updated meta-analysis [J].
Chen, Yun-lin ;
Fan, Jinqi ;
Chen, Guozhu ;
Cao, Li ;
Lu, Li ;
Xu, Yanping ;
Yin, Yuehui .
MEDICINE, 2019, 98 (15)
[23]   Three-year outcome of everolimus-eluting bioresorbable vascular scaffold versus everolimus-eluting metallic stents: a comprehensive updated meta-analysis of randomized controlled trials [J].
Zhang, Hongliang ;
Zhao, Jie ;
Xu, Yanlu ;
Zhang, Wenjia ;
Sui, Yonggang ;
Liu, Qingrong ;
Wang, Yubin ;
Liu, Zhihong ;
Gao, Runlin ;
Wu, Yongjian .
EXPERT REVIEW OF MEDICAL DEVICES, 2019, 16 (05) :421-427
[24]   Poly (l-lactic acid) bioresorbable scaffolds versus metallic drug-eluting stents for the treatment of coronary artery disease: A meta-analysis of 11 randomized trials [J].
Verdoia, Monica ;
Kedhi, Elvin ;
Suryapranata, Harry ;
Galasso, Gennaro ;
Dudek, Dariusz ;
De Luca, Giuseppe .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 96 (04) :813-824
[25]   Comparison of new-generation drug-eluting stents versus drug-coated balloon for in-stent restenosis: a meta-analysis of randomised controlled trials [J].
Cai, Jin-Zan ;
Zhu, Yong-Xiang ;
Wang, Xin-Yu ;
Bourantas, Christos V. ;
Iqbal, Javaid ;
Zhu, Hao ;
Cummins, Paul ;
Dong, Sheng-jie ;
Mathur, Anthony ;
Zhang, Yao-Jun .
BMJ OPEN, 2018, 8 (02)
[26]   From biodegradable polymers to bioresorbable vascular scaffolds: available evidence in the era of new-generation drug-eluting stents [J].
Magliulo, Fabio ;
Piccolo, Raffaele ;
Franzone, Anna ;
Esposito, Giovanni ;
Danzi, Gian B. .
MINERVA CARDIOANGIOLOGICA, 2018, 66 (03) :246-261
[27]   Five-Year Outcomes of Biodegradable Polymer Drug-Eluting Stents Versus Second-Generation Durable Polymer Drug-Eluting Stents: a Meta-Analysis of Randomized Controlled Trials [J].
Yake Lou ;
Ying Yu ;
Ziwei Xi ;
Yanan Gao ;
Wei Liu ;
Xiaomin Nie .
Cardiovascular Drugs and Therapy, 2019, 33 :557-566
[28]   Bioresorbable Scaffolds Versus Metallic Drug-Eluting Stents Are We Getting Any Closer to a Paradigm Shift? [J].
Windecker, Stephan ;
Koskinas, Konstantinos C. ;
Siontis, George C. M. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (21) :2310-2314
[29]   Drug-Eluting Balloons Versus Everolimus-Eluting Stents for In-Stent Restenosis: A Meta-Analysis of Randomized Trials [J].
Elgendy, Islam Y. ;
Mahmoud, Ahmed N. ;
Elgendy, Akram Y. ;
Mojadidi, Mohammad K. ;
Elbadawi, Ayman ;
Eshtehardi, Parham ;
Jose Perez-Vizcayno, Maria ;
Wayangankar, Siddharth A. ;
Jneid, Hani ;
Anderson, R. David ;
Alfonso, Fernando .
CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2019, 20 (07) :612-618
[30]   Double versus Provisional Stent Strategy for Coronary Bifurcation Using Drug-Eluting Stents: A Meta-Analysis of Randomized Controlled Trials [J].
Saurav, Alok ;
Kaja, Ajay K. ;
Kaushik, Manu ;
DelCore, Michael ;
Mooss, Aryan V. ;
Biddle, William .
CIRCULATION, 2014, 130