Modified RV short axis series - a new method for cardiac MRI measurement of right ventricular volumes

被引:38
作者
Strugnell, WE
Slaughter, RE
Riley, RA
Trotter, AJ
Bartlett, H
机构
[1] Prince Charles Hosp, Cardiovasc MRI Res Ctr, Brisbane, Qld 4032, Australia
[2] Queensland Univ Technol, Brisbane, Qld, Australia
关键词
cardiac MRI; right ventricular volume; right ventricular function; steady state free precession imaging (SSFP); FIESTA;
D O I
10.1080/10976640500295433
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose. The current standard image orientation employed in the MRI assessment of right ventricular volumes uses a series of short axis cine acquisitions located with respect to a horizontal long axis view with the first slice placed across the atrio-ventricular valve plane at end diastole. Inherent inaccuracies are encountered with the use of this image orientation due to difficulty in defining the tricuspid valve and the border between atrium and ventricle on the resultant images. Our experience indicates that because the tricuspid valve is usually not in-plane in the slice the atrio-ventricular margin is difficult to distinguish. This leads to inaccuracies in measurements at the base of the RV and miscalculation of the RV volume. The purpose of this study was to assess an alternative method of image orientation aimed at increasing the accuracy of RV volume measurements using current commercially available CMRI sequences. This technique, the modified RV short axis series, is oriented to the outflow tract of the right ventricle. Method. We undertook a prospective study of 50 post cardiac transplant patients. A series of LV short axis multi-slice cine acquisition FIESTA images was acquired using the current standard technique. From this data set, LV and RV stroke volumes were derived on all Advantage Windows workstation using planimetry of the endocardial and epicardial borders in end systole and end diastole. Our new technique involved obtaining a set of multi-slice cine acquisition FIESTA images in a plane perpendicular to a line from the centre of the pulmonary valve to the apex of the RV. Planimetry of the RV was then performed and a stroke volume calculated using the same method of analysis. RV stroke volumes obtained from both techniques were compared with LV stroke volumes. Three operators independently derived RV data sets. Results. On the images acquired with the new technique, the tricuspid valve was easier to define leading to more accurate and reproducible planimetry of ventricular borders. RV stroke volumes calculated from the new method showed better agreement with LV stroke volumes than with the current method. These results were consistent across the three operators. Conclusions. This new method improves visualisation of the tricuspid valve and makes analysis easier and less prone to operator error than the current standard technique for MRI assessment of RV volumes.
引用
收藏
页码:769 / 774
页数:6
相关论文
共 14 条
[1]   Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences [J].
Alfakih, K ;
Plein, S ;
Thiele, H ;
Jones, T ;
Ridgway, JP ;
Sivananthan, MU .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) :323-329
[2]  
ALFAKIH K, 2003, J CARDIVOASC MAGN RE, V5, P281
[3]   Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance [J].
Bellenger, NG ;
Davies, LC ;
Francis, JM ;
Coats, AJS ;
Pennell, DJ .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2000, 2 (04) :271-278
[4]   QUANTIFICATION OF RIGHT-VENTRICULAR FUNCTION WITH MAGNETIC-RESONANCE-IMAGING IN CHILDREN WITH NORMAL HEARTS AND WITH CONGENITAL HEART-DISEASE [J].
HELBING, WA ;
REBERGEN, SA ;
MALIEPAARD, C ;
HANSEN, B ;
OTTENKAMP, J ;
REIBER, JHC ;
DEROOS, A .
AMERICAN HEART JOURNAL, 1995, 130 (04) :828-837
[5]   WHICH STANDARD HAS THE GOLD [J].
HIGGINS, CB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (07) :1608-1609
[6]   Evaluation of methods for MR imaging of human right ventricular heart volumes and mass [J].
Jauhiainen, T ;
Järvinen, VM ;
Hekali, PE .
ACTA RADIOLOGICA, 2002, 43 (06) :587-592
[7]   MR gradient echo volumetric analysis of human cardiac casts:: Focus on the right ventricle [J].
Jauhiainen, T ;
Järvinen, VM ;
Hekali, PE ;
Poutanen, VP ;
Penttilä, A ;
Kupari, M .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (06) :899-903
[8]  
Jiang L, 1994, J Am Soc Echocardiogr, V7, P150
[9]  
LORENZ CH, 2002, CARDIOVASCULAR MAGNE, P283
[10]   Measurement of ventricular volumes by cine magnetic resonance imaging in complex congenital heart disease with morphologically abnormal ventricles [J].
Niwa, K ;
Uchishiba, M ;
Aotsuka, H ;
Tobita, K ;
Matsuo, K ;
Fujiwara, T ;
Tateno, S ;
Hamada, H .
AMERICAN HEART JOURNAL, 1996, 131 (03) :567-575