A patient-specific study of type-B aortic dissection: evaluation of true-false lumen blood exchange

被引:52
作者
Chen, Duanduan [1 ]
Mueller-Eschner, Matthias [2 ,3 ]
von Tengg-Kobligk, Hendrik [2 ,3 ,4 ]
Barber, David [5 ]
Boeckler, Dittmar [6 ]
Hose, Rod [5 ]
Ventikos, Yiannis [7 ]
机构
[1] Beijing Inst Technol, Sch Life Sci, Dept Biomed Engn, Beijing 100081, Peoples R China
[2] Univ Heidelberg Hosp, Dept Diagnost & Intervent Radiol, Heidelberg, Germany
[3] German Canc Res Ctr, Heidelberg, Germany
[4] Univ Hosp Bern, Inselspital, Inst Diagnost Intervent & Pediat Radiol DIPR, CH-3010 Bern, Switzerland
[5] Univ Sheffield, Med Phys Grp, Dept Cardiovasc Sci, Sheffield, S Yorkshire, England
[6] Heidelberg Univ, Dept Vasc Surg, Heidelberg, Germany
[7] UCL, Dept Mech Engn, London, England
基金
中国国家自然科学基金;
关键词
Aortic dissection; Computational fluid dynamics; Patient-specific model; Hemodynamics; COMPUTATIONAL FLUID-DYNAMICS; NUMERICAL-SIMULATION; SHEAR-STRESS; FLOW; MANAGEMENT; ANEURYSM; MODELS; WALL; CFD;
D O I
10.1186/1475-925X-12-65
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Aortic dissection is a severe pathological condition in which blood penetrates between layers of the aortic wall and creates a duplicate channel - the false lumen. This considerable change on the aortic morphology alters hemodynamic features dramatically and, in the case of rupture, induces markedly high rates of morbidity and mortality. Methods: In this study, we establish a patient-specific computational model and simulate the pulsatile blood flow within the dissected aorta. The k-omega SST turbulence model is employed to represent the flow and finite volume method is applied for numerical solutions. Our emphasis is on flow exchange between true and false lumen during the cardiac cycle and on quantifying the flow across specific passages. Loading distributions including pressure and wall shear stress have also been investigated and results of direct simulations are compared with solutions employing appropriate turbulence models. Results: Our results indicate that (i) high velocities occur at the periphery of the entries; (ii) for the case studied, approximately 40% of the blood flow passes the false lumen during a heartbeat cycle; (iii) higher pressures are found at the outer wall of the dissection, which may induce further dilation of the pseudo-lumen; (iv) highest wall shear stresses occur around the entries, perhaps indicating the vulnerability of this region to further splitting; and (v) laminar simulations with adequately fine mesh resolutions, especially refined near the walls, can capture similar flow patterns to the (coarser mesh) turbulent results, although the absolute magnitudes computed are in general smaller. Conclusions: The patient-specific model of aortic dissection provides detailed flow information of blood transport within the true and false lumen and quantifies the loading distributions over the aorta and dissection walls. This contributes to evaluating potential thrombotic behavior in the false lumen and is pivotal in guiding endovascular intervention. Moreover, as a computational study, mesh requirements to successfully evaluate the hemodynamic parameters have been proposed.
引用
收藏
页数:16
相关论文
共 46 条
  • [11] Fung Y., 1997, BIOMECHANICSCIRCULAT, Vsecond
  • [12] Motion characterization of aortic wall and intimal flap by ECG-gated CT in patients with chronic B-dissection
    Ganten, Maria-Katharina
    Weber, Tim F.
    von Tengg-Kobligk, Hendrik
    Boeckler, Dittmar
    Stiller, Wolfram
    Geisbuesch, Philipp
    Kauffmann, Guenter W.
    Delorme, Stefan
    Bock, Michael
    Kauczor, Hans-Ulrich
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (01) : 146 - 153
  • [13] Gardhagen R, 2006, WSEAS T BIOL BIOMEDI, V10, P609
  • [14] Spontaneous arterial dissection: phenotype and molecular pathogenesis
    Grond-Ginsbach, Caspar
    Pjontek, Rastislav
    Aksay, Suna Su
    Hyhlik-Duerr, Alexander
    Boeckler, Dittmar
    Gross-Weissmann, Marie-Luise
    [J]. CELLULAR AND MOLECULAR LIFE SCIENCES, 2010, 67 (11) : 1799 - 1815
  • [15] The International Registry of Acute Aortic Dissection (IRAD) - New insights into an old disease
    Hagan, PG
    Nienaber, CA
    Isselbacher, EM
    Bruckman, D
    Karavite, DJ
    Russman, PL
    Evangelista, A
    Fattori, R
    Suzuki, T
    Oh, JK
    Moore, AG
    Malouf, JF
    Pape, LA
    Gaca, C
    Sechtem, U
    Lenferink, S
    Deutsch, HJ
    Diedrichs, H
    Robles, JMY
    Llovet, A
    Gilon, D
    Das, SK
    Armstrong, WF
    Deeb, GM
    Eagle, KA
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2000, 283 (07): : 897 - 903
  • [16] PREDICTION OF LAMINARIZATION WITH A 2-EQUATION MODEL OF TURBULENCE
    JONES, WP
    LAUNDER, BE
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1972, 15 (02) : 301 - +
  • [17] LOCATION ON CHROMOSOME-15 OF THE GENE DEFECT CAUSING MARFAN-SYNDROME
    KAINULAINEN, K
    PULKKINEN, L
    SAVOLAINEN, A
    KAITILA, I
    PELTONEN, L
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1990, 323 (14) : 935 - 939
  • [18] Karmonik C, 2011, EUR J VASC ENDOVASC
  • [19] A Computational Fluid Dynamics Study Pre- and Post-Stent Graft Placement in an Acute Type B Aortic Dissection
    Karmonik, Christof
    Bismuth, Jean
    Davies, Mark G.
    Shah, Dipan J.
    Younes, Houssam K.
    Lumsden, Alan B.
    [J]. VASCULAR AND ENDOVASCULAR SURGERY, 2011, 45 (02) : 157 - 164
  • [20] Impact of Tear Location on Hemodynamics in a Type B Aortic Dissection investigated with Computational Fluid Dynamics
    Karmonik, Christof
    Bismuth, Jean
    Redel, Thomas
    Anaya-Ayala, Javier E.
    Davies, Mark G.
    Shah, Dipan J.
    Lumsden, Alan B.
    [J]. 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 3138 - 3141