A patient-specific study of type-B aortic dissection: evaluation of true-false lumen blood exchange

被引:52
作者
Chen, Duanduan [1 ]
Mueller-Eschner, Matthias [2 ,3 ]
von Tengg-Kobligk, Hendrik [2 ,3 ,4 ]
Barber, David [5 ]
Boeckler, Dittmar [6 ]
Hose, Rod [5 ]
Ventikos, Yiannis [7 ]
机构
[1] Beijing Inst Technol, Sch Life Sci, Dept Biomed Engn, Beijing 100081, Peoples R China
[2] Univ Heidelberg Hosp, Dept Diagnost & Intervent Radiol, Heidelberg, Germany
[3] German Canc Res Ctr, Heidelberg, Germany
[4] Univ Hosp Bern, Inselspital, Inst Diagnost Intervent & Pediat Radiol DIPR, CH-3010 Bern, Switzerland
[5] Univ Sheffield, Med Phys Grp, Dept Cardiovasc Sci, Sheffield, S Yorkshire, England
[6] Heidelberg Univ, Dept Vasc Surg, Heidelberg, Germany
[7] UCL, Dept Mech Engn, London, England
基金
中国国家自然科学基金;
关键词
Aortic dissection; Computational fluid dynamics; Patient-specific model; Hemodynamics; COMPUTATIONAL FLUID-DYNAMICS; NUMERICAL-SIMULATION; SHEAR-STRESS; FLOW; MANAGEMENT; ANEURYSM; MODELS; WALL; CFD;
D O I
10.1186/1475-925X-12-65
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Aortic dissection is a severe pathological condition in which blood penetrates between layers of the aortic wall and creates a duplicate channel - the false lumen. This considerable change on the aortic morphology alters hemodynamic features dramatically and, in the case of rupture, induces markedly high rates of morbidity and mortality. Methods: In this study, we establish a patient-specific computational model and simulate the pulsatile blood flow within the dissected aorta. The k-omega SST turbulence model is employed to represent the flow and finite volume method is applied for numerical solutions. Our emphasis is on flow exchange between true and false lumen during the cardiac cycle and on quantifying the flow across specific passages. Loading distributions including pressure and wall shear stress have also been investigated and results of direct simulations are compared with solutions employing appropriate turbulence models. Results: Our results indicate that (i) high velocities occur at the periphery of the entries; (ii) for the case studied, approximately 40% of the blood flow passes the false lumen during a heartbeat cycle; (iii) higher pressures are found at the outer wall of the dissection, which may induce further dilation of the pseudo-lumen; (iv) highest wall shear stresses occur around the entries, perhaps indicating the vulnerability of this region to further splitting; and (v) laminar simulations with adequately fine mesh resolutions, especially refined near the walls, can capture similar flow patterns to the (coarser mesh) turbulent results, although the absolute magnitudes computed are in general smaller. Conclusions: The patient-specific model of aortic dissection provides detailed flow information of blood transport within the true and false lumen and quantifies the loading distributions over the aorta and dissection walls. This contributes to evaluating potential thrombotic behavior in the false lumen and is pivotal in guiding endovascular intervention. Moreover, as a computational study, mesh requirements to successfully evaluate the hemodynamic parameters have been proposed.
引用
收藏
页数:16
相关论文
共 46 条
  • [1] Simulations of time harmonic blood flow in the Mesenteric artery: comparing finite element and lattice Boltzmann methods
    Axner, Lilit
    Hoekstra, Alfons G.
    Jeays, Adam
    Lawford, Pat
    Hose, Rod
    Sloot, Peter M. A.
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2009, 8 : 23
  • [2] Efficient computational fluid dynamics mesh generation by image registration
    Barber, D. C.
    Oubel, E.
    Frangi, A. F.
    Hose, D. R.
    [J]. MEDICAL IMAGE ANALYSIS, 2007, 11 (06) : 648 - 662
  • [3] Barber DC, 2006, SHEFFIELD IMAGE REGI
  • [4] Refinements in mathematical models to predict aneurysm growth and rupture
    Berguer, Ramon
    Bull, Joseph L.
    Khanafer, Khalil
    [J]. ABDOMINAL AORTIC ANEURYSM: GENETICS, PATHOPHYSIOLOGY AND MOLECULAR BIOLOGY, 2006, 1085 : 110 - 116
  • [5] A computational fluid dynamic study of stent graft remodeling after endovascular repair of thoracic aortic dissections
    Cheng, Stephen W. K.
    Lam, Edward S. K.
    Fung, George S. K.
    Ho, Pei
    Ting, Albert C. W.
    Chow, Kwok W.
    [J]. JOURNAL OF VASCULAR SURGERY, 2008, 48 (02) : 303 - 310
  • [6] Analysis of Flow Patterns in a Patient-Specific Aortic Dissection Model
    Cheng, Z.
    Tan, F. P. P.
    Riga, C. V.
    Bicknell, C. D.
    Hamady, M. S.
    Gibbs, R. G. J.
    Wood, N. B.
    Xu, X. Y.
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (05):
  • [7] COOLEY DA, 1990, TEX HEART I J, V17, P289
  • [8] Minimisation of the wall shear stress gradients in bypass grafts anastomoses using meshless CFD and genetic algorithms optimisation
    El Zahab, Zaher
    Divo, Eduardo
    Kassab, Alain
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2010, 13 (01) : 35 - 47
  • [9] Diagnosis and management of aortic dissection - Recommendations of the Task Force on Aortic Dissection, European Society of Cardiology
    Erbel, R
    Alfonso, F
    Boileau, C
    Dirsch, O
    Eber, B
    Haverich, A
    Rakowski, H
    Struyven, J
    Radegran, K
    Sechtem, U
    Taylor, J
    Zollikofer, C
    Klein, WW
    Mulder, B
    Providencia, LA
    [J]. EUROPEAN HEART JOURNAL, 2001, 22 (18) : 1642 - 1681
  • [10] A new method for the determination of aortic pulse wave velocity using cross-correlation on 2D PCMR velocity data
    Fielden, Samuel W.
    Fornwalt, Brandon K.
    Jerosch-Herold, Michael
    Eisner, Robert L.
    Stillman, Arthur E.
    Oshinski, John N.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (06) : 1382 - 1387