Scheimpflug imaging for keratoconus and ectatic disease

被引:99
作者
Belin, Michael W. [1 ]
Ambrosio, Renato, Jr. [2 ,3 ]
机构
[1] Univ Arizona, Southern Arizona VA Healthcare Syst, Tucson, AZ USA
[2] Univ Fed Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
[3] Inst Olhos Renato Ambrosio, Rio De Janeiro, Brazil
关键词
Ectatic disease; keratoconus; scheimpflug imaging; PELLUCID MARGINAL DEGENERATION; CORNEAL THICKNESS; TOMOGRAPHY; DIAGNOSIS; PENTACAM; ORBSCAN; ECTASIA;
D O I
10.4103/0301-4738.116059
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Scheimpflug cross-sectioning anterior segment imaging offers significant advantages over traditional placido based curvature analysis and ultrasound pachymetry. The accurate measurement of both the anterior and posterior corneal surfaces and the anterior and posterior lens allows for the creation of a three-dimensional reconstruction of the anterior segment. Changes on both the posterior cornea and/or corneal thickness map are earlier indicators of ectatic change than would otherwise be identifiable with only anterior curvature and ultrasonic pachymetry. Scheimpflug imaging also covers significantly more of the cornea than was possible with placido based devices. This added coverage is critical in the proper diagnosis of peripheral diseases such as pellucid marginal degeneration (PMD).
引用
收藏
页码:401 / 406
页数:6
相关论文
共 14 条
[1]  
Alió JL, 2006, J REFRACT SURG, V22, P539
[2]   Novel Pachymetric Parameters Based on Corneal Tomography for Diagnosing Keratoconus [J].
Ambrosio, Renato, Jr. ;
Caiado, Ana Laura C. ;
Guerra, Frederico P. ;
Louzada, Ricardo ;
Roy, Abhijit Sinha ;
Luz, Allan ;
Dupps, William J. ;
Belin, Michael W. .
JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (10) :753-758
[3]   Corneal Ectasia After LASIK Despite Low Preoperative Risk: Tomographic and Biomechanical Findings in the Unoperated, Stable, Fellow Eye [J].
Ambrosio, Renato, Jr. ;
Dawson, Daniel G. ;
Salomao, Marcella ;
Guerra, Frederico P. ;
Caiado, Ana Laura C. ;
Belin, Michael W. .
JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (11) :906-911
[4]  
Belin M.W., 2007, Highlights Ophthalmol, V35, P5
[5]   New devices and clinical implications for measuring corneal thickness [J].
Belin, Michael W. ;
Khachikian, Stephen S. .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (08) :729-731
[6]   What's in a Name: Keratoconus, Pellucid Marginal Degeneration, and Related Thinning Disorders [J].
Belin, Michael W. ;
Asota, Ijeoma M. ;
Ambrosio, Renato, Jr. ;
Khachikian, Stephen S. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 152 (02) :157-162
[7]   Evaluating data acquisition and smoothing functions of currently available videokeratoscopes [J].
Belin, MW ;
Ratliff, CD .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (04) :421-426
[8]   Comparison of corneal thickness measurements by ultrasound and scheimpflug photography in eyes that have undergone laser in situ keratomileusis [J].
Ciolino, Joseph B. ;
Khachikian, Steven S. ;
Belin, Michael W. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (01) :75-80
[9]   Corneal thickness changes after corneal collagen crosslinking for keratoconus and corneal ectasia: One-year results [J].
Greenstein, Steven A. ;
Shah, Vinnie P. ;
Fry, Kristen L. ;
Hersh, Peter S. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (04) :691-700
[10]   Intrasubject corneal thickness asymmetry [J].
Khachikian, Stephen S. ;
Belin, Michael W. ;
Ciolino, Joseph B. .
JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (06) :606-609