A thermal-neutron source for calibration of "zero-thickness" detectors

被引:0
|
作者
Koshelev, AS [1 ]
Odintsov, YM
Maslov, GN
Sevast'yanov, VD
机构
[1] Res Inst Physicotech & Radio Engn Measurements, Mendeleevo 141570, Moscow Oblast, Russia
[2] All Russian Res Inst Expt Phys, Russian Fed Nucl Ctr, Sarov 607200, Nizhni Novgorod, Russia
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A specialized source of thermal neutrons was produced on the basis of the BP-K1 research reactor. The thermal-neutron field characteristics were determined in the presence of intermediate and fast neutrons. The neutron spectrum is presented in analytical form in the 10(-10)-18-MeV energy range. In the maximum single energy run of the reactor with a duration of <2 min, the thermal-neutron fluence was 1.9 x 10(14) neutron/cm(2), with fluences of intermediate and fast neutrons of 0.4 x 10(14) and 0.3 x 10(14) neutron/cm(2), respectively. The effective temperature of thermal neutrons is 6.6 degrees C higher than the ambient temperature. The fraction of the field isotropic component is estimated as 80%.
引用
收藏
页码:303 / 309
页数:7
相关论文
共 50 条
  • [1] A thermal-neutron source for calibration of 'zero-thickness' detectors
    Koshelev, A.S.
    Odintsov, Yu.M.
    Maslov, G.N.
    Sevast'yanov, V.D.
    Pribory i Tekhnika Eksperimenta, 1999, 42 (03): : 303 - 309
  • [2] RADIATION AND THERMAL TESTS OF THERMAL-NEUTRON DETECTORS
    ZLOKAZOV, SB
    AFANASEV, PG
    NALIVAEV, VI
    PAMPURA, VB
    SAFIN, YA
    UVAROV, VI
    SOVIET ATOMIC ENERGY, 1981, 51 (05): : 743 - 744
  • [3] CALIBRATION OF DIRECT-CHARGING DETECTORS FOR MEASUREMENT OF ABSOLUTE THERMAL-NEUTRON FLUX
    ALEKSEEV, AE
    BABULEVI.EN
    GONCHARE.LA
    ZAGADKIN, VA
    KIRSANOV, VS
    KONONOVI.AA
    KUZNETSO.VM
    KUZNETSO.EM
    MITELMAN, MG
    POCHIVAL.GP
    ROZENBLY.ND
    SOVIET ATOMIC ENERGY-USSR, 1970, 28 (02): : 172 - &
  • [4] SENSITIVITY OF THERMAL-NEUTRON DETECTORS CONTAINING MODERATORS
    ALEINIKOV, VE
    ARKHIPOV, VA
    BESKROVNAYA, LG
    KOMOCHKOV, MM
    MOKROV, YV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1983, 26 (01) : 50 - 55
  • [5] THERMAL-NEUTRON DOSIMETRY WITH CADMIUM TELLURIDE DETECTORS
    FASASI, M
    JUNG, M
    SIFFERT, P
    TEISSIER, C
    RADIATION PROTECTION DOSIMETRY, 1988, 23 (1-4) : 429 - 431
  • [6] A SOURCE OF ERROR IN THERMAL-NEUTRON CONVERTERS
    KONDRASHOV, AV
    SOVIET ATOMIC ENERGY, 1983, 54 (05): : 365 - 366
  • [7] COMMENT ON USE OF THERMOLUMINESCENCE DOSIMETERS AS THERMAL-NEUTRON DETECTORS
    HOROWITZ, YS
    DUBI, A
    NUCLEAR INSTRUMENTS & METHODS, 1977, 146 (02): : 455 - 455
  • [8] HIGH-EFFICIENCY SEMICONDUCTOR THERMAL-NEUTRON DETECTORS
    MUMINOV, RA
    TSVANG, LD
    SOVIET ATOMIC ENERGY, 1987, 62 (04): : 316 - 319
  • [9] PLASTICS AS NUCLEAR TRACK DETECTORS FOR THERMAL-NEUTRON DOSIMETRY
    FARID, SM
    SHARMA, AP
    DURRANI, SA
    PRAMANA, 1983, 20 (06) : 559 - 567
  • [10] An open source program to generate zero-thickness cohesive interface elements
    Nguyen, Vinh Phu
    ADVANCES IN ENGINEERING SOFTWARE, 2014, 74 : 27 - 39