An investigation of the validity of the Lifeshirt in comparison to standard polysomnography in the detection of obstructive sleep apnea

被引:16
|
作者
Goodrich, Suanne [1 ]
Orr, William C. [1 ,2 ]
机构
[1] Lynn Hlth Sci Inst, Oklahoma City, OK 73112 USA
[2] Univ Oklahoma, Hlth Sci Ctr, Oklahoma City, OK 73104 USA
关键词
Apnea; Measurement; Airflow; Respiratory inductance plethysmography; Polysomnography; Portable sleep study; DIAGNOSIS; AGREEMENT; ACCESS;
D O I
10.1016/j.sleep.2007.11.003
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Due to the cost and waiting times for traditional sleep studies, there is great interest in finding alternatives for the diagnosis of sleep apnea. Several alternatives exist, including ambulatory devices. Our laboratory utilized one such device, a form-fitting vest called the Lifeshirt, and compared its accuracy to that of polysomnography (PSG). Methods: PSG was performed with simultaneous utilization of the Lifeshirt on 50 individuals who met screening criteria for obstructive sleep apnea. Participants came to the sleep laboratory approximately 2 h before their normal bedtime. A sleep technician prepared each participant for PSG and Lifeshirt monitoring. "Lights Out" occurred when the participant was ready for bed, and time in bed was standardized to approximately 7 h. PSGs were scored by experienced personnel in our laboratory, while Lifeshirt data were sent electronically to the Lifeshirt manufacturer for analysis. The major variable that was compared between PSG and Lifeshirt was the apnea hypopnea index (AHI), or the number of apneas and hypopneas per hour. Due to incomplete data on two participants, analyses were completed on 48 individuals. Results: Sensitivity of the Lifeshirt ranged from .85 (AHI of >= 5) to 1.00 (AHI of >= 25). Specificity ranged from .67 to 1.00. Using the Bland-Altman technique of determining agreement, the mean difference between the AHI of the Lifeshirt and PSG was 1.02 (+/- 16.36). When these values are plotted, every case falls within the limits of agreement, with one exception. Conclusions: The Lifeshirt compared favorably with PSG and could be used with considerable confidence for the screening of patients with suspected obstructive sleep apnea. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:118 / 122
页数:5
相关论文
共 50 条
  • [41] Evaluation of the accuracy of SNAP technology sleep Sonography in detecting obstructive sleep apnea in adults compared to standard polysomnography
    Liesching, TN
    Carlisle, C
    Marte, A
    Bonitati, A
    Millman, RP
    CHEST, 2004, 125 (03) : 886 - 891
  • [42] Screening for obstructive sleep apnea in the memory clinic: A comparison of questionnaires, pulse oximetry, and polysomnography
    Lam, Aaron
    D'Rozario, Angela L.
    Kong, Shawn
    Ireland, Catriona
    Mowszowski, Loren
    Lamonica, Haley M.
    Phillips, Craig L.
    Hoyos, Camilla M.
    Grunstein, Ronald R.
    Naismith, Sharon L.
    JOURNAL OF ALZHEIMERS DISEASE, 2025, 103 (01) : 218 - 229
  • [43] CAN WE TRULY CHANGE FROM POLYSOMNOGRAPHY TO POLYGRAPHY IN OBSTRUCTIVE SLEEP APNEA? A COMPARISON BETWEEN THESE TO LEVELS OF SLEEP STUDIES IN A POPULATION OF PATIENTS WITH OBSTRUCTIVE SLEEP APNEA
    Pereira, C.
    Moreira, S.
    Barros, A.
    Fernandes, D.
    Valenca, J.
    Pinto, P.
    Barbara, C.
    SLEEP MEDICINE, 2017, 40 : E258 - E259
  • [44] Continuous positive airway pressure device-based automated detection of obstructive sleep apnea compared to standard laboratory polysomnography
    Bharati Prasad
    David W. Carley
    James J. Herdegen
    Sleep and Breathing, 2010, 14 : 101 - 107
  • [45] Continuous positive airway pressure device-based automated detection of obstructive sleep apnea compared to standard laboratory polysomnography
    Prasad, Bharati
    Carley, David W.
    Herdegen, James J.
    SLEEP AND BREATHING, 2010, 14 (02) : 101 - 107
  • [46] Questionnaire OSA-18 has poor validity compared to polysomnography in pediatric obstructive sleep apnea
    Borgstrom, Anna
    Nerfeldt, Pia
    Friberg, Danielle
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2013, 77 (11) : 1864 - 1868
  • [47] Sleep Apnea Detection with Polysomnography and Depth Sensors
    Schatz, Martin
    Prochazka, Ales
    Kuchynka, Jiri
    Vysata, Oldrich
    SENSORS, 2020, 20 (05)
  • [48] Passive automatic detection of sleep APNEA and arousals compared to standard polysomnography: Preliminary validation
    Mack, D. C.
    Alwan, M.
    Turner, B.
    Felder, R.
    Suratt, P.
    SLEEP, 2006, 29 : A207 - A207
  • [49] Predictors of Obstructive Sleep Apnea on a Home Sleep Apnea Test After a Negative Attended Polysomnography
    Lipatov, Katie
    Hayek, Adam
    Ghamande, Shekhar
    Boethel, Carl
    Chen, Wencong
    Jones, Shirley
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2018, 14 (11): : 1889 - 1894
  • [50] A Comparison of the Reliability of Five Sleep Questionnaires for the Detection of Obstructive Sleep Apnea
    Solecka, Sarka
    Matler, Karel
    Kostlivy, Tomas
    Kubec, Vojtech
    Tomaskova, Hana
    Betka, Jaroslav
    LIFE-BASEL, 2022, 12 (09):