Stride length determination during overground running using a single foot-mounted inertial measurement unit

被引:19
作者
Brahms, C. Markus [1 ]
Zhao, Yang [2 ]
Gerhard, David [2 ]
Barden, John M. [1 ]
机构
[1] Univ Regina, Fac Kinesiol & Hlth Studies, 3737 Wascana Pkwy, Regina, SK S4S 0A2, Canada
[2] Univ Regina, Dept Comp Sci, Fac Sci, Regina, SK, Canada
关键词
Stride length; IMU; Sensor; Running; Pedestrian-dead reckoning; ZUPT;
D O I
10.1016/j.jbiomech.2018.02.003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
From a research perspective, detailed knowledge about stride length (SL) is important for coaches, clinicians and researchers because together with stride rate it determines the speed of locomotion. Moreover, individual SL vectors represent the integrated output of different biomechanical determinants and as such provide valuable insight into the control of running gait. In recent years, several studies have tried to estimate SL using body-mounted inertial measurement units (IMUs) and have reported promising results. However, many studies have used systems based on multiple sensors or have only focused on estimating SL for walking. Here we test the concurrent validity of a single foot-mounted, 9-degree of freedom IMU to estimate SL for running. We employed a running-specific, Kalman filter based zero-velocity update (ZUPT) algorithm to calculate individual SL vectors with the IMU and compared the results to SLs that were simultaneously recorded by a 6-camera 3D motion capture system. The results showed that the analytical procedures were able to successfully identify all strides that were recorded by the camera system and that excellent levels of absolute agreement (ICC(3,1) = 0.955) existed between the two methods. The findings demonstrate that individual SL vectors can be accurately estimated with a single foot-mounted IMU when running in a controlled laboratory setting. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:302 / 305
页数:4
相关论文
共 13 条
  • [1] Angermann Michael., 2010, INT C INDOOR POSITIO, P1
  • [2] Beauregard S., 2006, 3 INT FORUM APPL WEA, P1
  • [3] Towards high-precision IMU/GPS-based stride-parameter determination in an outdoor runners' scenario
    Bichler, Sebastian
    Ogris, Georg
    Kremser, Veronika
    Schwab, Florian
    Knott, Stefan
    Baca, Arnold
    [J]. ENGINEERING OF SPORT CONFERENCE 2012, 2012, 34 : 592 - 597
  • [4] Feliz R., 2009, Journal of Physical Agents, V3, P35, DOI [DOI 10.14198/JOPHA.2009.3.1.05, 10.14198/JoPha.2009.3.1.05]
  • [5] Tutorial: Implementing a Pedestrian Tracker Using Inertial Sensors
    Fischer, Carl
    Sukumar, Poorna Talkad
    Hazas, Mike
    [J]. IEEE PERVASIVE COMPUTING, 2013, 12 (02) : 17 - 27
  • [6] Cycle rate, length, and speed of progression in human locomotion
    Hay, JG
    [J]. JOURNAL OF APPLIED BIOMECHANICS, 2002, 18 (03) : 257 - 270
  • [7] Jiménez AR, 2009, I S INTELL SIG PR, P37, DOI 10.1109/WISP.2009.5286542
  • [8] Kim J. W., 2004, J GLOBAL POSITIONING, V3, P273, DOI DOI 10.5081/JGPS.3.1.273
  • [9] The Validity of Gait Variability and Fractal Dynamics Obtained From a Single Body-Fixed Triaxial Accelerometer
    Kobsar, Dylan
    Olson, Chad
    Paranjape, Raman
    Barden, John M.
    [J]. JOURNAL OF APPLIED BIOMECHANICS, 2014, 30 (02) : 343 - 347
  • [10] Maki Hiromichi, 2012, Biomed Sci Instrum, V48, P282