OSA treatment with CPAP: Randomized crossover study comparing tolerance and efficacy with and without humidification by ThermoSmart

被引:15
作者
Boyer, Laurent [1 ]
Philippe, Carole [2 ]
Covali-Noroc, Ala [1 ]
Dalloz, Marie-Amelie [3 ,5 ]
Rouvel-Tallec, Anny [3 ]
Maillard, Dominique [4 ,5 ]
Stoica, Maria [3 ]
d'Ortho, Marie-Pia [3 ,5 ]
机构
[1] Hop Henri Mondor, AP HP, DHU A TVB, Dept Physiol Explorat Fonct, Creteil, France
[2] Hop Univ Pitie Salpetriere, AP HP, Ctr Pathol Sommeil, Paris, France
[3] Hop Univ Bichat Claude Bernard, AP HP, Ctr Sommeil, DHU FIRE, Paris, France
[4] Hop Univ Louis Mourier, AP HP, Serv Physiol Explorat Fonct, Colombes, France
[5] Univ Paris 07, UFR Med, Paris, France
关键词
CPAP; humidification; obstructive sleep apnea syndrome; POSITIVE AIRWAY PRESSURE; OBSTRUCTIVE SLEEP-APNEA; HEATED BREATHING TUBE; MUCOCILIARY CLEARANCE; ADHERENCE; THERAPY; SYMPTOMS; INFLAMMATION; FREQUENCY; QUALITY;
D O I
10.1111/crj.13022
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Objectives Adherence to continuous positive airway pressure (CPAP) remains an issue, as adverse effects (AE) such as rhinitis, dry/congested nose, dry mouth or throat are commonly experienced. The aim of the study was to compare CPAP efficacy and tolerance in severe obstructive sleep apnea (OSA) patients with or without (w/o) heated humidification using the ThermoSmart system. Methods Multicenter RCT study in which CPAP-naive patients with severe OSA and meeting one or more of the following criteria: >65 years, using >1 drying medication, previous nasal symptoms or nasal surgery, were included. Patients were randomized to CPAP w/o heated humidification for 1 month and then crossed-over to the other treatment arm for another month. Naso-pharyngeal symptoms, Quality of life (FOSQ-10), sleepiness (ESS) and CPAP compliance and efficacy data were collected. Results Forty patients were enrolled: age 62 +/- 9 years, diagnostic AHI 46.7 +/- 15.3/hour. About 70% were using >1 drying medication, mainly antihypertensives. Both treatment modalities were found to normalize AHI and decrease sleepiness with no differences between 2 modes, compliance (4.63 +/- 0.39 vs 4.70 +/- 0.36 h/night) or leaks (32.4 +/- 2.0 versus 31.1 +/- 1.7l/min). With heated humidification, there was a significant decrease in nasal symptoms such as dry/congested nose. At the study end, 26 patients preferred ThermoSmart ON, 3 did not have preference and 11 preferred ThermoSmart OFF. Conclusion ThermoSmart helps to decrease nose and throat discomfort because of CPAP therapy, these effects did not translate to better compliance but patients had a preference for ThermoSmart.
引用
收藏
页码:384 / 390
页数:7
相关论文
共 23 条
[1]   Type of Mask May Impact on Continuous Positive Airway Pressure Adherence in Apneic Patients [J].
Borel, Jean Christian ;
Tamisier, Renaud ;
Dias-Domingos, Sonia ;
Sapene, Marc ;
Martin, Francis ;
Stach, Bruno ;
Grillet, Yves ;
Muir, Jean Francois ;
Levy, Patrick ;
Series, Frederic ;
Pepin, Jean-Louis .
PLOS ONE, 2013, 8 (05)
[2]   Effects of long-term nasal continuous positive airway pressure therapy on morphology, function, and mucociliary clearance of nasal epithelium in patients with obstructive sleep apnea syndrome [J].
Bossi, R ;
Piatti, G ;
Roma, E ;
Ambrosetti, U .
LARYNGOSCOPE, 2004, 114 (08) :1431-1434
[3]   Sleep apnea is associated with bronchial inflammation and continuous positive airway pressure-induced airway hyperresponsiveness [J].
Devouassoux, Gilles ;
Levy, Patrick ;
Rossini, Eliane ;
Pin, Isabelle ;
Fior-Gozlan, Michele ;
Henry, Mireille ;
Seigneurin, Daniel ;
Pepin, Jean-Louis .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2007, 119 (03) :597-603
[4]  
EDELSTEIN DR, 2009, LARYNGOSCOPE S81 2, V106, P1
[5]   Effect of a Heated Breathing Tube on Efficacy, Adherence and Side Effects during Continuous Positive Airway Pressure Therapy in Obstructive Sleep Apnea [J].
Galetke, Wolfgang ;
Nothofer, Eleonore ;
Priegnitz, Christina ;
Anduleit, Norbert ;
Randerath, Winfried .
RESPIRATION, 2016, 91 (01) :18-25
[6]   The effect of aging on nasal mucociliary clearance, beat frequency, and ultrastructure of respiratory cilia [J].
Ho, JC ;
Chan, KN ;
Hu, WH ;
Lam, WK ;
Zheng, L ;
Tipoe, GL ;
Sun, J ;
Leung, R ;
Tsang, KW .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 163 (04) :983-988
[7]   Predictors of long-term compliance with continuous positive airway pressure [J].
Kohler, Malcolm ;
Smith, Debbie ;
Tippett, Victoria ;
Stradling, John R. .
THORAX, 2010, 65 (09) :829-832
[8]   Nasal inflammation in sleep apnoea patients using CPAP and effect of heated humidification [J].
Koutsourelakis, I. ;
Vagiakis, E. ;
Perraki, E. ;
Karatza, M. ;
Magkou, C. ;
Kopaka, M. ;
Roussos, C. ;
Zakynthinos, S. .
EUROPEAN RESPIRATORY JOURNAL, 2011, 37 (03) :587-594
[9]   Persistence of Upper-Airway Symptoms During CPAP Compromises Adherence at 1 Year [J].
Kreivi, Hanna-Riikka ;
Maasilta, Paula ;
Bachour, Adel .
RESPIRATORY CARE, 2016, 61 (05) :652-657
[10]   Frequency of Upper Airway Symptoms before and during Continuous Positive Airway Pressure Treatment in Patients with Obstructive Sleep Apnea Syndrome [J].
Kreivi, Hanna-Riikka ;
Virkkula, Paula ;
Lehto, Juho ;
Brander, Pirkko .
RESPIRATION, 2010, 80 (06) :488-494