Amplified impedimetric aptasensor based on gold nanoparticles covalently bound graphene sheet for the picomolar detection of ochratoxin A

被引:107
作者
Jiang, Ling [1 ]
Qian, Jing [1 ]
Yang, Xingwang [1 ]
Yan, Yuting [1 ]
Liu, Qian [1 ]
Wang, Kan [1 ]
Wang, Kun [1 ]
机构
[1] Jiangsu Univ, Sch Chem & Chem Engn, Key Lab Modern Agr Equipment & Technol, Zhenjiang 212013, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Gold nanoparticles covalently bound graphene; Signal amplification; Impedimetric; Aptasensor; Ochratoxin A; LABEL-FREE DETECTION; ELECTROCHEMICAL APTASENSOR; SENSING PLATFORM; DNA APTAMER; BIOSENSOR; SURFACE; OXIDE; FOOD; HYBRIDIZATION; SPECTROSCOPY;
D O I
10.1016/j.aca.2013.11.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amplified electrochemical impedimetric aptasensor for ochratoxin A (OTA) was developed with picomolar sensitivity. A facile route to fabricate gold nanoparticles covalently bound reduced graphene oxide (AuNPs-rGO) resulted in a large number of well-dispersed AuNPs on graphene sheets with tremendous binding sites for DNA, since the single rGO sheet and each AuNP can be loaded with hundreds of DNA strands. An aptasensor with sandwich model was fabricated which involved thiolated capture DNA immobilized on a gold electrode to capture the aptamer, then the sensing interface was incubated with OTA at a desired concentration, followed by AuNPs-rGO functionalized reporter DNA hybridized with the residual aptamers. By exploiting the AuNPs-rGO as an excellent signal amplified platform, a single hybridization event between aptamer and reporter DNA was translated into more than 10(7) redox events, leading to a substantial increase in charge-transfer resistance (R-ct) by 7 similar to orders of magnitude compared with that of the free aptamer modified electrode. Such designed aptasensor showed a decreased response of R-ct to the increase of OTA concentrations over a wide range of 1 pg mL(-1)-50 ng mL(-1) and could detect extremely low OTA concentration, namely, 0.3 pg mL(-1) or 0.74 pM, which was much lower than that of most other existed impedimetric aptasensors. The signal amplification platform presented here would provide a promising model for the aptamer-based detection with a direct impedimetric method. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:128 / 135
页数:8
相关论文
共 46 条
[31]   Ochratoxin A removal in wine: A review [J].
Quintela, Silvia ;
Carmen Villaran, Ma ;
Lopez de Armentia, Iratxe ;
Elejalde, Edurne .
FOOD CONTROL, 2013, 30 (02) :439-445
[32]   Reusable impedimetric aptasensor [J].
Radi, AE ;
Sánchez, JLA ;
Baldrich, E ;
O'Sullivan, CK .
ANALYTICAL CHEMISTRY, 2005, 77 (19) :6320-6323
[33]   Application of locked nucleic acids to improve aptamer in vivo stability and targeting function [J].
Schmidt, KS ;
Borkowski, S ;
Kurreck, J ;
Stephens, AW ;
Bald, R ;
Hecht, M ;
Friebe, M ;
Dinkelborg, L ;
Erdmann, VA .
NUCLEIC ACIDS RESEARCH, 2004, 32 (19) :5757-5765
[34]   PVP-coated graphene oxide for selective determination of ochratoxin A via quenching fluorescence of free aptamer [J].
Sheng, Linfeng ;
Ren, Jiangtao ;
Miao, Yuqing ;
Wang, Jiahai ;
Wang, Erkang .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (08) :3494-3499
[35]   Nanoparticle-Enhanced Sensitivity of a Nanogap-Interdigitated Electrode Array Impedimetric Biosensor [J].
Singh, Kanwar V. ;
Bhura, Dheeraj K. ;
Nandamuri, Gopichand ;
Whited, Allison M. ;
Evans, David ;
King, Jeff ;
Solanki, Raj .
LANGMUIR, 2011, 27 (22) :13931-13939
[36]   Double-probe signal enhancing strategy for toxin aptasensing based on rolling circle amplification [J].
Tong, Ping ;
Zhao, Wei-Wei ;
Zhang, Lan ;
Xu, Jing-Juan ;
Chen, Hong-Yuan .
BIOSENSORS & BIOELECTRONICS, 2012, 33 (01) :146-151
[37]   Simply amplified electrochemical aptasensor of Ochratoxin A based on exonuclease-catalyzed target recycling [J].
Tong, Ping ;
Zhang, Lan ;
Xu, Jing-Juan ;
Chen, Hong-Yuan .
BIOSENSORS & BIOELECTRONICS, 2011, 29 (01) :97-101
[38]   Sensitive immunoassay of a biomarker tumor necrosis factor-α based on poly(guanine)-functionalized silica nanoparticle label [J].
Wang, Jun ;
Liu, Guodong ;
Engelhard, Mark H. ;
Lin, Yuehe .
ANALYTICAL CHEMISTRY, 2006, 78 (19) :6974-6979
[39]   An aptamer-based chromatographic strip assay for sensitive toxin semi-quantitative detection [J].
Wang, Libing ;
Ma, Wenwei ;
Chen, Wei ;
Liu, Liqiang ;
Ma, Wei ;
Zhu, Yingyue ;
Xu, Liguang ;
Kuang, Hua ;
Xu, Chuanlai .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (06) :3059-3062
[40]   Electrochemiluminescent aptamer biosensor for the determination of ochratoxin A at a gold-nanoparticles-modified gold electrode using N-(aminobutyl)-N-ethylisoluminol as a luminescent label [J].
Wang, Zhouping ;
Duan, Nuo ;
Hun, Xu ;
Wu, Shijia .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (05) :2125-2132