Robotic single-site hysterectomy: feasibility, learning curve and surgical outcome

被引:57
作者
Cela, V. [1 ]
Freschi, L. [1 ]
Simi, G. [1 ]
Ruggiero, M. [1 ]
Tana, R. [1 ]
Pluchino, N. [1 ]
机构
[1] Univ Pisa, Div Obstet & Gynecol, Pisa, Italy
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2013年 / 27卷 / 07期
关键词
Single-site; Robotic; Feasibility; Learning curve; Hysterectomy; SURGERY; CHOLECYSTECTOMY; EXPERIENCE;
D O I
10.1007/s00464-012-2780-8
中图分类号
R61 [外科手术学];
学科分类号
摘要
The field of laparoscopy has undergone several changes to improve the morbidity and cosmesis of laparoscopic surgery. The robotic single-site surgery is the inevitable hybridization of robotic technology with laparoendoscopic single-site surgery. Perioperative information of 12 robotic single-site hysterectomies (R-SSH) were collected to evaluate the surgical feasibility and the possible influence of the body mass index (BMI) and the uterine weight on operative times. The mean operative time was 85 +/- A 33 min (range, 355 to 149 min), the mean docking time was 9 +/- A 3 min, and the mean console time was 76 +/- A 33 min. The mean blood loss was 80 +/- A 18 mL, and the median weight of resected uteri was 220 +/- A 45 g. No serious postoperative complications occurred. The CUSUM learning curve was observed to consist of two different phases: phase 1 (the initial 6 cases) and phase 2 (the last 6 cases) with significant reduction in operative and console time observed between the two phases. For BMI, no correlation was found with operative times, console times, and docking times, and no correlation was found between uterine weight and operative time. This series, identifying two different phases of the learning curve and suggesting that the initial learning phase for the procedure can be achieved after six cases, confirms the feasibility and safety of a robotic approach for single-site hysterectomy. However, the limits of this study mainly rely on the limited casuistic and short follow-up, although the preliminary results appear promising. Larger series and prospective studies comparing R-SSH hysterectomy with standard robotic multiport hysterectomy are necessary to define properly the role of this innovative surgical technique.
引用
收藏
页码:2638 / 2643
页数:6
相关论文
共 14 条
[1]   Learning curve for robotic-assisted laparoscopic colorectal surgery [J].
Bokhari, Malak B. ;
Patel, Chirag B. ;
Ramos-Valadez, Diego I. ;
Ragupathi, Madhu ;
Haas, Eric M. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2011, 25 (03) :855-860
[2]   Learning curve for robot-assisted Roux-en-Y gastric bypass [J].
Buchs, Nicolas C. ;
Pugin, Francois ;
Bucher, Pascal ;
Hagen, Monika E. ;
Chassot, Gilles ;
Koutny-Fong, Pascale ;
Morel, Philippe .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2012, 26 (04) :1116-1121
[3]   da Vinci® single-site platform: anthropometrical, docking and suturing considerations for hysterectomy in the cadaver model [J].
Escobar, Pedro F. ;
Knight, Jason ;
Rao, Sanjay ;
Weinberg, Lori .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2012, 8 (02) :191-195
[4]   Single-Port Surgery: Laboratory Experience with the daVinci Single-Site Platform [J].
Escobar, Pedro F. ;
Haber, Georges-Pascal ;
Kaouk, Jihad ;
Kroh, Matthew ;
Chalikonda, Sricharan ;
Falcone, Tommaso .
JSLS-JOURNAL OF THE SOCIETY OF LAPAROENDOSCOPIC SURGEONS, 2011, 15 (02) :136-141
[5]   Evaluation of a novel single-port robotic platform in the cadaver model for the performance of various procedures in gynecologic oncology [J].
Escobar, Pedro F. ;
Kebria, Mehdi ;
Falcone, Tommaso .
GYNECOLOGIC ONCOLOGY, 2011, 120 (03) :380-384
[6]   Novel Robotic da Vinci Instruments for Laparoendoscopic Single-site Surgery [J].
Haber, Georges-Pascal ;
White, Michael A. ;
Autorino, Riccardo ;
Escobar, Pedro F. ;
Kroh, Matthew D. ;
Chalikonda, Sricharan ;
Khanna, Rakesh ;
Forest, Sylvain ;
Yang, Bo ;
Altunrende, Fatih ;
Stein, Robert J. ;
Kaouk, Jihad H. .
UROLOGY, 2010, 76 (06) :1279-1282
[7]   Single-Port Laparoscopic and Robotic Partial Nephrectomy [J].
Kaouk, Jihad H. ;
Goel, Raj K. .
EUROPEAN UROLOGY, 2009, 55 (05) :1163-1169
[8]   Cholecystectomy using a novel Single-SiteA® robotic platform: early experience from 45 consecutive cases [J].
Konstantinidis, Konstantinos M. ;
Hirides, Petros ;
Hirides, Savas ;
Chrysocheris, Pericles ;
Georgiou, Michael .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2012, 26 (09) :2687-2694
[9]   Robotic single-port transumbilical total hysterectomy: a pilot study [J].
Nam, Eun Ji ;
Kim, Sang Wun ;
Lee, Maria ;
Yim, Ga Won ;
Paek, Ji Heum ;
Lee, San Hui ;
Kim, Sunghoon ;
Kim, Jae Hoon ;
Kim, Jae Wook ;
Kim, Young Tae .
JOURNAL OF GYNECOLOGIC ONCOLOGY, 2011, 22 (02) :120-126
[10]   Overcoming the Challenges of Single-Incision Cholecystectomy With Robotic Single-Site Technology [J].
Pietrabissa, Andrea ;
Sbrana, Fabio ;
Morelli, Luca ;
Badessi, Francesco ;
Pugliese, Luigi ;
Vinci, Alessio ;
Klersy, Catherine ;
Spinoglio, Giuseppe .
ARCHIVES OF SURGERY, 2012, 147 (08) :709-714