Hyaluronidase treatment of synovial fluid to improve assay precision for biomarker research using multiplex immunoassay platforms

被引:32
作者
Jayadev, Chethan [1 ]
Rout, Raj [1 ]
Price, Andrew [1 ]
Hulley, Philippa [1 ]
Mahoney, David [1 ]
机构
[1] Univ Oxford, Nuffield Dept Orthopaed Rheumatol & Musculoskelet, Oxford OX1 2JD, England
关键词
Synovial Fluid; Immunoassay; Precision; Luminex; Meso Scale Discovery; LIGAND-BINDING ASSAYS; CELL COUNTS; OSTEOARTHRITIS; VALIDATION; VISCOSITY; ARTHRITIS; MEDIATORS; BLOOD;
D O I
10.1016/j.jim.2012.08.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Synovial fluid (SF) is a difficult biological matrix to analyse due to its complex non-Newtonian nature. This can result in poor assay repeatability and potentially inefficient use of precious samples. This study assessed the impact of SF treatment by hyaluronidase and/or dilution on intra-assay precision using the Luminex and Meso Scale Discovery (MSD) multiplex platforms. SF was obtained from patients with knee osteoarthritis at the time of joint replacement surgery. Aliquots derived from the same sample were left untreated (neat), 2-fold diluted, 4-fold diluted or treated with 2 mg/ml testicular hyaluronidase (with 2-fold dilution). Preparation methods were compared in a polysterene-bead Luminex 10-plex (N=16), magnetic-bead Luminex singleplex (N=7) and MSD 4-plex (N=7). Each method was assessed for coefficient of variation (CV) of replicate measurements, number of bead events (for Luminex assays) and dilution-adjusted analyte concentration. Percentage recovery was calculated for dilutions and HAse treatment. Hyaluronidase treatment significantly increased the number of wells with satisfactory bead events/region (95%) compared to neat (48%, p<0.001) in the polystyrene-bead Luminex assay, but the magnetic-bead Luminex assay achieved >= 50 bead events irrespective of treatment method. Hyaluronidase treatment resulted in lower intra-assay CVs for detectable ligands (group average CV<10%) than neat, 2-fold and 4-fold dilution (CV similar to 25% for all, p<0.05) in both polystyrene- and magnetic-bead Luminex assays. In addition, measured sample concentrations were higher and recovery was poor (elevated) after hyaluronidase treatment. In the MSD 4-plex, within-group comparison of the intra-assay CV or concentration was not conclusively influenced by SF preparation. However, only hyaluronidase treatment resulted in CV<25% for all samples for TNF-alpha. There was no effect on analyte concentrations or recovery. Hyaluronidase treatment can improve intra-assay precision and assay signal of SF analysis by multiplex immunoassays and should be recommended for SF biomarker research, particularly using the Luminex platform. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:22 / 30
页数:9
相关论文
共 26 条
[1]   Measurement of cytokines in clinical samples using immunoassays: Problems and pitfalls [J].
Banks, RE .
CRITICAL REVIEWS IN CLINICAL LABORATORY SCIENCES, 2000, 37 (02) :131-182
[2]  
Cook D., 2008, EVALUATION LUMINEX I
[3]   Blood and synovial fluid cytokine signatures in patients with juvenile idiopathic arthritis: a cross-sectional study [J].
de Jager, Wilco ;
Hoppenreijs, Esther P. A. H. ;
Wulffraat, Nico M. ;
Wedderburn, Lucy R. ;
Kuis, Wietse ;
Prakken, Berent J. .
ANNALS OF THE RHEUMATIC DISEASES, 2007, 66 (05) :589-598
[4]   Recommendations for the bioanalytical method validation of ligand-binding assays to support pharmacokinetic assessments of macromolecules [J].
DeSilva, B ;
Smith, W ;
Weiner, R ;
Kelley, M ;
Smolec, JM ;
Lee, B ;
Khan, M ;
Tacey, R ;
Hill, H ;
Celniker, A .
PHARMACEUTICAL RESEARCH, 2003, 20 (11) :1885-1900
[5]   Methods of sputum processing for cell counts, immunocytochemistry and in situ hybridisation [J].
Efthimiadis, A ;
Spanevello, A ;
Hamid, Q ;
Kelly, MM ;
Linden, M ;
Louis, R ;
Pizzichini, MMM ;
Pizzichini, E ;
Ronchi, C ;
Van Overveld, F ;
Djukanovic, R .
EUROPEAN RESPIRATORY JOURNAL, 2002, 20 :19S-23S
[6]   Automated counting of nucleated cells in equine synovial fluid without and with hyaluronidase pretreatment [J].
Ekmann, Anita ;
Rigdal, Marie-Louise ;
Grondahl, Gittan .
VETERINARY CLINICAL PATHOLOGY, 2010, 39 (01) :83-89
[7]  
Fam H, 2007, BIORHEOLOGY, V44, P59
[8]   Analysis of individual data from bead-based assays ("bead arrays") [J].
Jacobson, James W. ;
Oliver, Kerry G. ;
Weiss, Christy ;
Kettman, John .
CYTOMETRY PART A, 2006, 69A (05) :384-390
[9]   VISCOSITY OF NORMAL AND PATHOLOGICAL HUMAN SYNOVIAL FLUIDS [J].
JOHNSTON, JP .
BIOCHEMICAL JOURNAL, 1955, 59 (04) :633-637
[10]   Analysis of fluid-phase mediators [J].
Kelly, MM ;
Keatings, V ;
Leigh, R ;
Peterson, C ;
Shute, J ;
Venge, P ;
Djukanovic, R .
EUROPEAN RESPIRATORY JOURNAL, 2002, 20 :24S-39S