In Vitro Comparison of Cyclic Fatigue Resistance of ProTaper, WaveOne, and Twisted Files

被引:52
作者
Castello-Escriva, Ricardo [1 ]
Alegre-Domingo, Teresa [1 ]
Faus-Matoses, Vicente [1 ]
Roman-Richon, Sophie [1 ]
Faus-Llacer, Vicente J. [1 ]
机构
[1] Univ Valencia, Sch Med & Dent, Dept Restorat Dent & Endodont, Valencia, Spain
关键词
Cyclic fatigue; endodontic instruments; nickel-titanium; reciprocating movement; WaveOne; TITANIUM ROTARY INSTRUMENTS;
D O I
10.1016/j.joen.2012.07.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of this study was to compare the cyclic fatigue resistance of 3 nickel-titanium (NiTi) endodontic instruments from ProTaper, WaveOne (WO), and Twisted Files (TF). Methods: Cyclic fatigue testing was conducted by operating instruments from ProTaper F2, WO 25.08, and TF 25.08. A total of 184 instruments were rotated in 4 curved artificial canals with different angles and radius of curvature. The time and cycles to failure were calculated. The data were compared for differences by using 2-way analysis of variance (P < .05). Results: In general, WO was the most resistant to fatigue failure of the tested instruments, and TF showed a higher number of cycles to failure than ProTaper. Conclusions: Reciprocating movement of WO showed a longer cyclic fatigue life than conventional rotary movement of TF and ProTaper. The new manufacturing twisting process of TF produced NiTi rotary instruments more resistant to fatigue than ProTaper instruments produced with the traditional NiTi grinding process. (J Endod 2012;38:1521-1524)
引用
收藏
页码:1521 / 1524
页数:4
相关论文
共 26 条
[1]   Evaluation of single-use rotary nickel-titanium instruments [J].
Arens, FC ;
Hoen, MM ;
Steiman, HR ;
Dietz, GC .
JOURNAL OF ENDODONTICS, 2003, 29 (10) :664-666
[2]   Root Canal Anatomy Preservation of WaveOne Reciprocating Files with or without Glide Path [J].
Berutti, Elio ;
Paolino, Davide Salvatore ;
Chiandussi, Giorgio ;
Alovisi, Mario ;
Cantatore, Giuseppe ;
Castellucci, Arnaldo ;
Pasqualini, Damiano .
JOURNAL OF ENDODONTICS, 2012, 38 (01) :101-104
[3]   An In Vitro Cyclic Fatigue Analysis of Different Endodontic Nickel-Titanium Rotary Instruments [J].
Bhagabati, Nilav ;
Yadav, Seema ;
Talwar, Sangeeta .
JOURNAL OF ENDODONTICS, 2012, 38 (04) :515-518
[4]   Analysis of mechanical preparations in extracted teeth using ProTaper rotary instruments: Value of the safety quotient [J].
Blum, JY ;
Machtou, P ;
Ruddle, C ;
Micallef, JP .
JOURNAL OF ENDODONTICS, 2003, 29 (09) :567-575
[5]   Resistance to Cyclic Fatigue Failure of a New Endodontic Rotary File [J].
Bouska, Jason ;
Justman, Bruce ;
Williamson, Anne ;
DeLong, Christopher ;
Qian, Fang .
JOURNAL OF ENDODONTICS, 2012, 38 (05) :667-669
[6]   Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement [J].
De-Deus, G. ;
Moreira, E. J. L. ;
Lopes, H. P. ;
Elias, C. N. .
INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (12) :1063-1068
[7]   Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors [J].
Gambarini, G .
JOURNAL OF ENDODONTICS, 2001, 27 (12) :772-774
[8]   Cyclic fatigue of Profile rotary instruments after prolonged clinical use [J].
Gambarini, G .
INTERNATIONAL ENDODONTIC JOURNAL, 2001, 34 (05) :386-389
[9]   Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods [J].
Gambarini, Gianluca ;
Grande, Nicola Maria ;
Plotino, Gianluca ;
Somma, Francesco ;
Garala, Manish ;
De Luca, Massimo ;
Testarelli, Luca .
JOURNAL OF ENDODONTICS, 2008, 34 (08) :1003-1005
[10]   Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems [J].
Grande, N. M. ;
Plotino, G. ;
Pecci, R. ;
Bedini, R. ;
Malagnino, V. A. ;
Somma, F. .
INTERNATIONAL ENDODONTIC JOURNAL, 2006, 39 (10) :755-763