Shoulder sensorimotor control assessment by force platform: feasibility and reliability

被引:13
作者
Edouard, Pascal [1 ,2 ,3 ]
Gasq, David [4 ]
Calmels, Paul [1 ,2 ,3 ]
Ducrot, Sarah [1 ,2 ]
Degache, Francis [5 ]
机构
[1] Univ Hosp St Etienne, Dept Phys Med, St Etienne, France
[2] Univ Hosp St Etienne, Dept Rehabil Clin & Exercise Physiol, St Etienne, France
[3] Univ Lyon, Lab Exercise Physiol LPE EA 4338, St Etienne, France
[4] Univ Hosp Toulouse Rangueil, Dept Funct Physiol Explorat, Toulouse, France
[5] Univ Lausanne, Dept Physiol, Fac Biol & Med, Inst Sport Sci, Lausanne, Switzerland
关键词
centre of pressure; metrology; neuromuscular control; reproducibility; shoulder assessment; stabilometry; ATHLETIC SHOULDER; PRESSURE MEASURES; REHABILITATION; STABILITY; SYSTEM;
D O I
10.1111/j.1475-097X.2012.01140.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Given the important role of the shoulder sensorimotor system in shoulder stability, its assessment appears of interest. Force platform monitoring of centre of pressure (CoP) in upper-limb weight-bearing positions is of interest as it allows integration of all aspects of shoulder sensorimotor control. This study aimed to determine the feasibility and reliability of shoulder sensorimotor control assessment by force platform. Forty-five healthy subjects performed two sessions of CoP measurement using Win-Posturo (R) Medicapteurs force platform in an upper-limb weight-bearing position with the lower limbs resting on a table to either the anterior superior iliac spines (P1) or upper patellar poles (P2). Four different conditions were tested in each position in random order: eyes open or eyes closed with trunk supported by both hands and eyes open with trunk supported on the dominant or non-dominant side. P1 reliability values were globally moderate to high for CoP length, CoP velocity and CoP standard deviation (SD), standard error of measurement ranged from 6.0% to 26.5%, except for CoP area. P2 reliability values were globally low and not clinically acceptable. Our results suggest that shoulder sensorimotor control assessment by force platform is feasible and has good reliability in upper-limb weight-bearing positions when the lower limbs are resting on a table to the anterior superior iliac spines. CoP length, CoP velocity and CoP SD velocity appear to be the most reliable variables.
引用
收藏
页码:409 / 413
页数:5
相关论文
共 11 条
[1]   Anterior Glenohumeral Joint Dislocations [J].
Dodson, Christopher C. ;
Cordasco, Frank A. .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2008, 39 (04) :507-518
[2]  
FURMAN JMR, 1993, NEUROLOGY, V43, P1261
[3]   Measures of reliability in sports medicine and science [J].
Hopkins, WG .
SPORTS MEDICINE, 2000, 30 (01) :1-15
[4]   Reliability of center of pressure measures of postural stability in healthy older adults: Effects of postural task difficulty and cognitive load [J].
Moghadam, Mojgan ;
Ashayeri, Hassan ;
Salavati, Mahyar ;
Sarafzadeh, Javad ;
Taghipoor, Keyvan Davatgaran ;
Saeedi, Ahmad ;
Salehi, Reza .
GAIT & POSTURE, 2011, 33 (04) :651-655
[5]  
Myers JB, 2000, J ATHL TRAINING, V35, P351
[6]   Sensorimotor contribution to shoulder stability: Effect of injury and rehabilitation [J].
Myers, Joseph B. ;
Wassinger, Craig A. ;
Lephart, Scott M. .
MANUAL THERAPY, 2006, 11 (03) :197-201
[7]  
Pontillo Marisa, 2007, N Am J Sports Phys Ther, V2, P90
[8]  
Riemann BL, 2002, J ATHL TRAINING, V37, P85
[9]   The test-retest reliability of centre of pressure measures in bipedal static task conditions - A systematic review of the literature [J].
Ruhe, Alexander ;
Fejer, Rene ;
Walker, Bruce .
GAIT & POSTURE, 2010, 32 (04) :436-445
[10]   Shoulder musculature activation during upper extremity weight-bearing exercise [J].
Uhl, TL ;
Carver, TJ ;
Mattacola, CG ;
Mair, SD ;
Nitz, AJ .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2003, 33 (03) :109-117