Solid phase microextraction sampling for a rapid and simple on-site evaluation of volatile organic compounds emitted from building materials

被引:27
作者
Nicolle, Jerome [1 ,2 ]
Desauziers, Valerie [1 ]
Mocho, Pierre [2 ]
机构
[1] Ecole Mines Ales, Lab Genie Environm Ind, F-64053 Pau 9, France
[2] Univ Pau & Pays Adour, Lab Therm Energet & Procedes, F-64000 Pau, France
关键词
Indoor air; Building material; VOC; SPME sampling; Emission cell;
D O I
10.1016/j.chroma.2008.08.061
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new sampling method was developed for a simple and fast evaluation of volatile organic compounds (VOCs) emitted at trace levels from building materials. The device involves an emission cell coupled with solid phase microextraction (SPME) for diffusive sampling. Owing to possible competitive adsorption of VOCs onto the PDMS-Carboxen fiber used. the co-adsorption conditions were determined through kinetics study of isolated and in mixture compounds. Hence. the linear concentration ranges which ensure reliable quantification were determined from 4.8 to 10 mg m(-3) min according to the VOC studied. Thus, the analyst can select the extraction time that fits for his best analytical objectives. For example, sub mu g m(-3) limits of detection can be achieved for GC-MS analysis for 20 min extraction. On the other hand, 5 min sampling is sufficient for a rapid screening of the major emitted VOCs, since the average limit of quantification reaches 20 mu g m(-3) for GC-FID analysis. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 15
页数:6
相关论文
共 25 条
[1]  
*AFNOR ISO, 2006, 160009 AFNOR ISO
[2]  
*AFNOR ISO, 2006, 1600010 AFNOR ISO
[3]  
*AFSSET, 2006, RAPP GROUP TRAV AFSS
[4]  
AgBB, 2008, HLTH REL EV PROC VOL
[5]  
[Anonymous], MAT EMISSION DATABAS
[6]  
[Anonymous], IND AIR QUAL ITS IMP
[7]   An automated monitoring system for VOC ozone precursors in ambient air:: development, implementation and data analysis [J].
Badol, C ;
Borbon, A ;
Locoge, N ;
Léonardis, T ;
Galloo, JC .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (07) :1815-1827
[8]   Traceability of pollutant measurements for ambient air monitoring [J].
Desauziers, V .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2004, 23 (03) :252-260
[9]   Determination of benzene, toluene, ethylbenzene and xylenes in indoor air at environmental levels using diffusive samplers in combination with headspace solid-phase microextraction and high-resolution gas chromatography-flame ionization detection [J].
Elke, K ;
Jermann, E ;
Begerow, J ;
Dunemann, L .
JOURNAL OF CHROMATOGRAPHY A, 1998, 826 (02) :191-200
[10]  
Incropera F.P., 2012, PRINCIPLEHEAT MASS