BAND ANALYSIS OF HYDRATED HUMAN SKIN STRATUM CORNEUM ATTENUATED TOTAL REFLECTANCE FOURIER TRANSFORM INFRARED SPECTRA IN VIVO

被引:88
|
作者
Lucassen, Gerald W. [1 ]
van Veen, Gerard N. A. [1 ]
Jansen, Jan A. J. [2 ]
机构
[1] Philips Res, Personal Care Inst, NL-5656 AA Eindhoven, Netherlands
[2] Philips Ctr Mfg Technol, Eindhoven, Netherlands
关键词
stratum corneum; water; hydration; fit analysis; moisturing factor; absorbance ratio; penetration depth;
D O I
10.1117/1.429890
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Water content is an important factor for skin condition. The determination of the hydration state of the skin is necessary to obtain basic knowledge about the penetration and loss of water in the skin stratum corneum. Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy is used to measure hydration of the stratum corneum. In this study we apply direct band fitting of the water bending, combination, and OH stretch bands over the 4000-650 cm(-1) wave number range. Measurements are performed on the volar aspect of the forearm using a Nicolet 800 FTIR spectrometer equipped with an ATR unit with a ZnSe crystal. Hydration of the skin is obtained by occlusion keeping the forearm pressed onto the crystal. Spectra are recorded before and after occlusion up to 30 min. The spectra are fitted with a nonlinear least-squares algorithm with Gaussian bands. Separate band fits of water, normal stratum corneum, and occluded hydrated stratum corneum spectra are obtained yielding band parameters of the individual water contributions in the bending mode at 1640 cm(-1), the combination band at 2125 cm(-1), and the OH stretches in the hydrated skin stratum corneum spectra. A scaling factor representing the contribution of the water spectrum into the skin stratum corneum spectrum is determined during the occlusion process. In comparison to the dependence of the infrared absorbance ratio in time used by Potts, our scaling factor shows a more distinct transition from enhanced signal due to increased contact area to extra signal due to water content at maximum contact area. Band fit analysis of hydrated skin stratum corneum ATR-FTIR spectra offers the possibility for quantitative determination of individual water band parameters. (C) 1998 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:267 / 280
页数:14
相关论文
共 50 条
  • [31] FOURIER-TRANSFORM INFRARED ATTENUATED TOTAL REFLECTION STUDY ON SUBTRANSITION OF HYDRATED DIPALMITOYLPHOSPHATIDYLCHOLINE MULTIBILAYERS
    OKAMURA, E
    UMEMURA, J
    TAKENAKA, T
    VIBRATIONAL SPECTROSCOPY, 1991, 2 (2-3) : 95 - 100
  • [32] DESTABILIZATION OF WHOLE SKIN LIPID BIO-LIPOSOMES INDUCED BY SKIN PENETRATION ENHANCERS AND FT-IR ATR (FOURIER-TRANSFORM INFRARED ATTENUATED TOTAL REFLECTION) ANALYSIS OF STRATUM-CORNEUM LIPIDS
    TAKEUCHI, Y
    YASUKAWA, H
    YAMAOKA, Y
    MORIMOTO, Y
    NAKAO, S
    FUKUMORI, Y
    FUKUDA, T
    CHEMICAL & PHARMACEUTICAL BULLETIN, 1992, 40 (02) : 484 - 487
  • [33] Application of Linear Discriminant Analysis and Attenuated Total Reflectance Fourier Transform Infrared Microspectroscopy for Diagnosis of Colon Cancer
    Khanmohammadi, Mohammadreza
    Garmarudi, Amir Bagheri
    Samani, Simin
    Ghasemi, Keyvan
    Ashuri, Ahmad
    PATHOLOGY & ONCOLOGY RESEARCH, 2011, 17 (02) : 435 - 441
  • [34] Comparison of photoacoustic and attenuated total reflectance for the qualitative analysis of a bituminous Colombian coal by Fourier transform infrared spectroscopy
    Acosta-Perez, P. L.
    Mejia-Ospino, E.
    Cabanzo, R.
    INTERNATIONAL SCIENCE WEEK: CHALLENGES OF SCIENCE IN THE 21ST CENTURY, 2019, 1159
  • [35] Differentiation of locally manufactured Kajal by Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy supported by chemometric analysis
    Sharma, Sweety
    Chophi, Rito
    Kumar, Raj
    Sharma, Vishal
    Singh, Rajinder
    FORENSIC SCIENCE INTERNATIONAL, 2019, 303
  • [36] Attenuated total reflection Fourier transform infrared and polarization spectroscopy of in vivo human skin ablated, layer by layer, by erbium:YAG laser
    Sviridov, AP
    Zimnyakov, DA
    Sinichkin, YP
    Butvina, LN
    Omelchenko, AJ
    Shakh, GS
    Bagratashvili, VN
    JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (04) : 820 - 827
  • [37] Use of infrared attenuated total reflectance spectroscopy for the in vivo measurement of hydration level and silicone distribution in the stratum corneum following shin coverage by polymeric dressings
    Branagan, M
    Chenery, DH
    Nicholson, S
    SKIN PHARMACOLOGY AND APPLIED SKIN PHYSIOLOGY, 2000, 13 (3-4): : 157 - 164
  • [38] OLEIC-ACID CONCENTRATION AND EFFECT IN HUMAN STRATUM-CORNEUM - NONINVASIVE DETERMINATION BY ATTENUATED TOTAL REFLECTANCE INFRARED-SPECTROSCOPY INVIVO
    MAK, VHW
    POTTS, RO
    GUY, RH
    JOURNAL OF CONTROLLED RELEASE, 1990, 12 (01) : 67 - 75
  • [39] Rapid determination of swiss cheese composition by Fourier transform infrared/attenuated total reflectance spectroscopy
    Rodriguez-Saona, LE
    Koca, N
    Harper, WJ
    Alvarez, VB
    JOURNAL OF DAIRY SCIENCE, 2006, 89 (05) : 1407 - 1412
  • [40] RAPID IDENTIFICATION AND CLASSIFICATION OF STAPHYLOCOCCUS AUREUS BY ATTENUATED TOTAL REFLECTANCE FOURIER TRANSFORM INFRARED SPECTROSCOPY
    Xie, Yanping
    Xu, Shujun
    Hu, Yu
    Chen, Wanyi
    He, Yiping
    Shi, Xianming
    JOURNAL OF FOOD SAFETY, 2012, 32 (02) : 176 - 183