Dynamic Magnetic Resonance Imaging of the Cervical Spine with High-Resolution 3-Dimensional T2-Imaging

被引:23
作者
Bostel, T. [1 ,2 ]
Gerigk, L. [1 ,3 ]
Hegewald, A. [4 ]
Thome, C. [4 ]
Scharf, J. [1 ]
Groden, C. [1 ]
Neumaier-Probst, E. [1 ]
机构
[1] Heidelberg Univ, Med Fac Mannheim, Dept Neuroradiol, D-68167 Mannheim, Germany
[2] Johannes Gutenberg Univ Mainz, Dept Radiol, Mainz, Germany
[3] German Canc Res Ctr, D-6900 Heidelberg, Germany
[4] Heidelberg Univ, Med Fac Mannheim, Dept Neurosurg, D-68167 Mannheim, Germany
关键词
Magnetic resonance imaging; Cervical spine; Image enhancement; Motion pictures as topic; Instrumentation; FLEXION EXTENSION; FOLLOW-UP; MRI; RADICULOPATHY; ARTHRODESIS; ADJACENT; FUSION; DISKECTOMY; MYELOPATHY; DEVICE;
D O I
10.1007/s00062-011-0121-2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose Imaging of the cervical spine in functional positions has so far been limited to conventional X-ray examinations or the scarcely available open magnetic resonance imaging (MRI). An MRI compatible positioning device allows MRI examinations in various positions and even in motion. In combination with high-resolution T2-weighted MRI it allows detailed functional imaging of the cervical spine and nerve roots. To evaluate the utility of this method a population of patients from a clinical study was examined 5 years after anterior cervical discectomy and fusion (ACDF). Methods A total of 32 patients (median age 51.5 years, 15 female, 17 male) were examined after a median interval of 64.3 months from ACDF including 16 patients with a titanium cage and 16 with autologous bone graft. The prototype of an MR compatible positioning device (NeuroSwing) was used for MRI of the cervical spine in functional positions on a 1.5 T MRI unit (Siemens Avanto). A real-time true fast imaging with steady-state precession (FISP) sequence [6 mm, TR 704, TE 1.3 ms, matrix 256 x 207, field of view (FoV) 22 cm] was used for monitoring of flexion up to 45 and extension up to 40 or until patient discomfort. A sagittal T2 sampling perfection with application optimized contrast using different flip angle evolution sequence (SPACE sequence, 0.9 mm isotropic voxels, TR 1770, TE 186 ms, matrix 320 x 318, FoV 28 cm) and an axial true FISP sequence (3 mm slices, TR 194, TE 1.9 ms, matrix 256 x 256, FoV 22 cm) were used for imaging in the end positions. Results Using the motorized positioning device and a real-time true FISP sequence, imaging of the cervical spine in flexion and extension motion was possible in a quality suitable to observe changes in the alignment of vertebral bodies, the width of the spinal canal and the spinal cord itself. The 3D T2-weighted SPACE sequence yielded high quality and resolution images in the maximum flexion and extension positions. Compared to primary axial T2 true FISP slices, axial reconstructions of the T2 SPACE sequence were found to be clearly less affected by metal artifacts with the additional benefit of multiplanar and transforaminal reconstructions. Conclusions T he combination of a mechanical positioning device and a high-resolution 3D T2-weighted sequence (SPACE) on a conventional 1.5 T MRI allows kinematic imaging of the cervical spine as well as high-resolution imaging in the end positions, even in the presence of metal implants. In this proof of concept study a good visualization of narrowing of the spinal canal in functional positions could be achieved, showing the potential of MRI in functional positions for clinical and research applications.
引用
收藏
页码:93 / 99
页数:7
相关论文
共 24 条
  • [1] Allmann KH, 1999, ROFO-FORTSCHR RONTG, V170, P22
  • [2] LATE RADIOGRAPHIC FINDINGS AFTER ANTERIOR CERVICAL FUSION FOR SPONDYLOTIC MYELORADICULOPATHY
    BABA, H
    FURUSAWA, N
    IMURA, S
    KAWAHARA, N
    TSUCHIYA, H
    TOMITA, K
    [J]. SPINE, 1993, 18 (15) : 2167 - 2173
  • [3] ROBINSON ANTERIOR CERVICAL DISKECTOMY AND ARTHRODESIS FOR CERVICAL RADICULOPATHY - LONG-TERM FOLLOW-UP OF 100 AND 22 PATIENTS
    BOHLMAN, HH
    EMERY, SE
    GOODFELLOW, DB
    JONES, PK
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (09) : 1298 - 1307
  • [4] CLINICAL VALIDATION OF FUNCTIONAL FLEXION EXTENSION RADIOGRAPHS OF THE CERVICAL-SPINE
    DVORAK, J
    PANJABI, MM
    GROB, D
    NOVOTNY, JE
    ANTINNES, JA
    [J]. SPINE, 1993, 18 (01) : 120 - 127
  • [5] FUNCTIONAL RADIOGRAPHIC DIAGNOSIS OF THE CERVICAL-SPINE - FLEXION EXTENSION
    DVORAK, J
    FROEHLICH, D
    PENNING, L
    BAUMGARTNER, H
    PANJABI, MM
    [J]. SPINE, 1988, 13 (07) : 748 - 755
  • [6] Open stand-up MRI - A new instrument for positional neuroimaging
    Gilbert, John W.
    Wheeler, Greg R.
    Lingreen, Richard A.
    Johnson, Robert R.
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2006, 19 (02): : 151 - 154
  • [7] Hilibrand A.S., 2004, The Spine Journal, V4, P190, DOI DOI 10.1016/J.SPINEE.2004.07.007
  • [8] Radiculopathy and myelopathy at segments adjacent to the site of a previous anterior cervical arthrodesis
    Hilibrand, AS
    Carlson, GD
    Palumbo, MA
    Jones, PK
    Bohlman, HH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (04) : 519 - 528
  • [9] Ishihara Hirokazu, 2004, Spine J, V4, P624, DOI 10.1016/j.spinee.2004.04.011
  • [10] Upright, weight-bearing, dynamic-kinetic MRI of the spine: initial results
    Jinkins, JR
    Dworkin, JS
    Damadian, RV
    [J]. EUROPEAN RADIOLOGY, 2005, 15 (09) : 1815 - 1825