Wavelet-based calculation of cerebral angiographic data from time-resolved CT perfusion acquisitions

被引:10
作者
Havla, Lukas [1 ]
Thierfelder, Kolja M. [2 ]
Beyer, Sebastian E. [2 ]
Sommer, Wieland H. [2 ]
Dietrich, Olaf [1 ]
机构
[1] Ludwig Maximilians Univ Hosp Munich, Inst Clin Radiol, Josef Lissner Lab Biomed Imaging, D-81377 Munich, Germany
[2] Ludwig Maximilians Univ Hosp Munich, Inst Clin Radiol, D-81377 Munich, Germany
关键词
X-ray computed tomography; Angiography; Perfusion; Wavelet analysis; Brain; ACUTE ISCHEMIC-STROKE; INTRAVENOUS THROMBOLYSIS; COLLATERAL CIRCULATION; IMAGES; SIGNAL;
D O I
10.1007/s00330-015-3651-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate a new approach for reconstructing angiographic images by application of wavelet transforms on CT perfusion data. Fifteen consecutive patients with suspected stroke were examined with a multi-detector CT acquiring 32 dynamic phases (a dagger t = 1.5s) of 99 slices (total slab thickness 99mm) at 80kV/200mAs. Thirty-five mL of iomeprol-350 was injected (flow rate = 4.5mL/s). Angiographic datasets were calculated after initial rigid-body motion correction using (a) temporally filtered maximum intensity projections (tMIP) and (b) the wavelet transform (Paul wavelet, order 1) of each voxel time course. The maximum of the wavelet-power-spectrum was defined as the angiographic signal intensity. The contrast-to-noise ratio (CNR) of 18 different vessel segments was quantified and two blinded readers rated the images qualitatively using 5pt Likert scales. The CNR for the wavelet angiography (501.8 +/- 433.0) was significantly higher than for the tMIP approach (55.7 +/- 29.7, Wilcoxon test p < 0.00001). Image quality was rated to be significantly higher (p < 0.001) for the wavelet angiography with median scores of 4/4 (reader 1/reader 2) than the tMIP (scores of 3/3). The proposed calculation approach for angiography data using temporal wavelet transforms of intracranial CT perfusion datasets provides higher vascular contrast and intrinsic removal of non-enhancing structures such as bone. aEuro cent Angiographic images calculated with the proposed wavelet-based approach show significantly improved contrast-to-noise ratio. aEuro cent CT perfusion-based wavelet angiography is an alternative method for vessel visualization. aEuro cent Provides intrinsic removal of non-enhancing structures such as bone.
引用
收藏
页码:2354 / 2361
页数:8
相关论文
共 22 条
[1]  
[Anonymous], P ESMRMB ANT
[2]  
[Anonymous], J MATH ANAL APPL
[3]   Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches [J].
Bae, Kyongtae T. .
RADIOLOGY, 2010, 256 (01) :32-61
[4]  
Beier J, 1998, RADIOLOGE, V38, P832, DOI 10.1007/s001170050431
[5]  
Boas FE., 2012, IMAGING MED, V4, P229, DOI [DOI 10.2217/IIM.12.13, 10.2217/iim.12.13]
[6]   Collateral circulation on perfusion-computed tomography-source images predicts the response to stroke intravenous thrombolysis [J].
Calleja, A. I. ;
Cortijo, E. ;
Garcia-Bermejo, P. ;
Gomez, R. D. ;
Perez-Fernandez, S. ;
del Monte, J. M. ;
Munoz, M. F. ;
Fernandez-Herranz, R. ;
Arenillas, J. F. .
EUROPEAN JOURNAL OF NEUROLOGY, 2013, 20 (05) :795-802
[7]   THE WAVELET TRANSFORM, TIME-FREQUENCY LOCALIZATION AND SIGNAL ANALYSIS [J].
DAUBECHIES, I .
IEEE TRANSACTIONS ON INFORMATION THEORY, 1990, 36 (05) :961-1005
[8]   WAVELET TRANSFORMS AND THEIR APPLICATIONS TO TURBULENCE [J].
FARGE, M .
ANNUAL REVIEW OF FLUID MECHANICS, 1992, 24 :395-457
[9]   elastix: A Toolbox for Intensity-Based Medical Image Registration [J].
Klein, Stefan ;
Staring, Marius ;
Murphy, Keelin ;
Viergever, Max A. ;
Pluim, Josien P. W. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (01) :196-205
[10]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174