Transcatheter Laceration of Aortic Leaflets to Prevent Coronary Obstruction During Transcatheter Aortic Valve Replacement Concept to First-in-Human

被引:201
作者
Khan, Jaffar M. [1 ]
Dvir, Danny [2 ]
Greenbaum, Adam B. [3 ,4 ]
Babaliaros, Vasilis C. [5 ]
Rogers, Toby [1 ]
Aldea, Gabriel [2 ]
Reisman, Mark [2 ]
Mackensen, G. Burkhard [2 ]
Eng, Marvin H. K. [3 ,4 ]
Paone, Gaetano [3 ,4 ]
Wang, Dee Dee [3 ,4 ]
Guyton, Robert A. [5 ]
Devireddy, Chandan M. [5 ]
Schenke, William H. [1 ]
Lederman, Robert J. [1 ]
机构
[1] NHLBI, Cardiovasc Branch, Div Intramural Res, NIH, Bldg 10,Room 2c713,MSC 1538, Bethesda, MD 20892 USA
[2] Univ Washington, Seattle, WA 98195 USA
[3] Henry Ford Hlth Syst, Div Cardiol, Ctr Struct Heart Dis, Detroit, MI USA
[4] Henry Ford Hlth Syst, Div Cardiac Surg, Detroit, MI USA
[5] Emory Univ Hosp, Struct Heart & Valve Ctr, 1364 Clifton Rd NE, Atlanta, GA 30322 USA
基金
美国国家卫生研究院;
关键词
bioprosthetic heart valve failure; coronary artery obstruction; structural heart disease; transcatheter aortic valve replacement; transcatheter electrosurgery; BIOPROSTHETIC SURGICAL VALVES; INTERMEDIATE-RISK PATIENTS; CLINICAL-OUTCOMES; IMPLANTATION; REGISTRY; PROTECTION; INSIGHTS; IMPACT;
D O I
10.1016/j.jcin.2018.01.247
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to develop a novel technique called bioprosthetic or native aortic scallop intentional laceration to prevent coronary artery obstruction (BASILICA). BACKGROUND Coronary artery obstruction is a rare but fatal complication of transcatheter aortic valve replacement (TAVR). METHODS We lacerated pericardial leaflets in vitro using catheter electrosurgery, and tested leaflet splaying after benchtop TAVR. The procedure was tested in swine. BASILICA was then offered to patients at high risk of coronary obstruction from TAVR and ineligible for surgical aortic valve replacement. BASILICA used marketed devices. Catheters directed an electrified guidewire to traverse and lacerate the aortic leaflet down the center line. TAVR was performed as usual. RESULTS TAVR splayed lacerated bovine pericardial leaflets. BASILICA was successful in pigs, both to left and right cusps. Necropsy revealed full length lacerations with no collateral thermal injury. Seven patients underwent BASILICA on a compassionate basis. Six had failed bioprosthetic valves, both stented and stent-less. Two had severe aortic stenosis, including 1 patient with native disease, 3 had severe aortic regurgitation, and 2 had mixed aortic valve disease. One patient required laceration of both left and right coronary cusps. There was no hemodynamic compromise in any patient following BASILICA. All patients had successful TAVR, with no coronary obstruction, stroke, or any major complications. All patients survived to 30 days. CONCLUSIONS BASILICA may durably prevent coronary obstruction from TAVR. The procedure was successful across a range of presentations, and requires further evaluation in a prospective trial. Its role in treatment of degenerated TAVR devices remains untested. Published by Elsevier on behalf of the American College of Cardiology Foundation.
引用
收藏
页码:677 / 689
页数:13
相关论文
共 15 条
[1]  
Abramowitz Y, 2015, EUROINTERVENTION, V11, P572, DOI 10.4244/EIJV11I5A112
[2]   Intentional Percutaneous Laceration of the Anterior Mitral Leaflet to Prevent Outflow Obstruction During Transcatheter Mitral Valve Replacement First-in-Human Experience [J].
Babaliaros, Vasilis C. ;
Greenbaum, Adam B. ;
Khan, Jaffar M. ;
Rogers, Toby ;
Wang, Dee Dee ;
Eng, Marvin H. ;
O'Neill, William W. ;
Paone, Gaetano ;
Thourani, Vinod H. ;
Lerakis, Stamatios ;
Kim, Dennis W. ;
Chen, Marcus Y. ;
Lederman, Robert J. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (08) :798-809
[3]   Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement [J].
Chhatriwalla, Adnan K. ;
Allen, Keith B. ;
Saxon, John T. ;
Cohen, David J. ;
Aggarwal, Sanjeev ;
Hart, Anthony J. ;
Baron, Suzanne J. ;
Dvir, Danny ;
Borkon, A. Michael .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (07)
[4]  
Dvir D, 2017, TRANSC VALV THER JUN
[5]   Transcatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical Valves [J].
Dvir, Danny ;
Webb, John G. ;
Bleiziffer, Sabine ;
Pasic, Miralem ;
Waksman, Ron ;
Kodali, Susheel ;
Barbanti, Marco ;
Latib, Azeem ;
Schaefer, Ulrich ;
Rodes-Cabau, Josep ;
Treede, Hendrik ;
Piazza, Nicolo ;
Hildick-Smith, David ;
Himbert, Dominique ;
Walther, Thomas ;
Hengstenberg, Christian ;
Nissen, Henrik ;
Bekeredjian, Raffi ;
Presbitero, Patrizia ;
Ferrari, Enrico ;
Segev, Amit ;
de Weger, Arend ;
Windecker, Stephan ;
Moat, Neil E. ;
Napodano, Massimo ;
Wilbring, Manuel ;
Cerillo, Alfredo G. ;
Brecker, Stephen ;
Tchetche, Didier ;
Lefevre, Thierry ;
De Marco, Federico ;
Fiorina, Claudia ;
Petronio, Anna Sonia ;
Teles, Rui C. ;
Testa, Luca ;
Laborde, Jean-Claude ;
Leon, Martin B. ;
Kornowski, Ran .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 312 (02) :162-170
[6]   Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves Results From the Global Valve-in-Valve Registry [J].
Dvir, Danny ;
Webb, John ;
Brecker, Stephen ;
Bleiziffer, Sabine ;
Hildick-Smith, David ;
Colombo, Antonio ;
Descoutures, Fleur ;
Hengstenberg, Christian ;
Moat, Neil E. ;
Bekeredjian, Raffi ;
Napodano, Massimo ;
Testa, Luca ;
Lefevre, Thierry ;
Guetta, Victor ;
Nissen, Henrik ;
Hernandez, Jose-Maria ;
Roy, David ;
Teles, Rui C. ;
Segev, Amit ;
Dumonteil, Nicolas ;
Fiorina, Claudia ;
Gotzmann, Michael ;
Tchetche, Didier ;
Abdel-Wahab, Mohamed ;
De Marco, Federico ;
Baumbach, Andreas ;
Laborde, Jean-Claude ;
Kornowski, Ran .
CIRCULATION, 2012, 126 (19) :2335-+
[7]  
Kappetein AP, 2012, J AM COLL CARDIOL, V60, P1438, DOI [10.1016/j.jacc.2012.09.001, 10.1093/ejcts/ezs533]
[8]   Intentional Laceration of the Anterior Mitral Valve Leaflet to Prevent Left Ventricular Outflow Tract Obstruction During Transcatheter Mitral Valve Replacement [J].
Khan, Jaffar M. ;
Rogers, Toby ;
Schenke, William H. ;
Mazal, Jonathan R. ;
Faranesh, Anthony Z. ;
Greenbaum, Adam B. ;
Babaliaros, Vasilis C. ;
Chen, Marcus Y. ;
Lederman, Robert J. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (17) :1835-1843
[9]   Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients [J].
Leon, Martin B. ;
Smith, Craig R. ;
Mack, Michael J. ;
Makkar, Raj R. ;
Svensson, Lars G. ;
Kodali, Susheel K. ;
Thourani, Vinod H. ;
Tuzcu, E. Murat ;
Miller, D. Craig ;
Herrmann, Howard C. ;
Doshi, Darshan ;
Cohen, David J. ;
Pichard, Augusto D. ;
Kapadia, Samir ;
Dewey, Todd ;
Babaliaros, Vasilis ;
Szeto, Wilson Y. ;
Williams, Mathew R. ;
Kereiakes, Dean ;
Zajarias, Alan ;
Greason, Kevin L. ;
Whisenant, Brian K. ;
Hodson, Robert W. ;
Moses, Jeffrey W. ;
Trento, Alfredo ;
Brown, David L. ;
Fearon, William F. ;
Pibarot, Philippe ;
Hahn, Rebecca T. ;
Jaber, Wael A. ;
Anderson, William N. ;
Alu, Maria C. ;
Webb, John G. .
NEW ENGLAND JOURNAL OF MEDICINE, 2016, 374 (17) :1609-1620
[10]   Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients [J].
Reardon, M. J. ;
Van Mieghem, N. M. ;
Popma, J. J. ;
Kleiman, N. S. ;
Sondergaard, L. ;
Mumtaz, M. ;
Adams, D. H. ;
Deeb, G. M. ;
Maini, B. ;
Gada, H. ;
Chetcuti, S. ;
Gleason, T. ;
Heiser, J. ;
Lange, R. ;
Merhi, W. ;
Oh, J. K. ;
Olsen, P. S. ;
Piazza, N. ;
Williams, M. ;
Windecker, S. ;
Yakubov, S. J. ;
Grube, E. ;
Makkar, R. ;
Lee, J. S. ;
Conte, J. ;
Vang, E. ;
Nguyen, H. ;
Chang, Y. ;
Mugglin, A. S. ;
Serruys, P. W. J. C. ;
Kappetein, A. P. .
NEW ENGLAND JOURNAL OF MEDICINE, 2017, 376 (14) :1321-1331