Comparative evaluation of a laboratory and full-scale treatment alternatives for the vegetable oil refining industry wastewater (VORW)

被引:56
作者
Azbar, N [1 ]
Yonar, T
机构
[1] Balikesir Univ, Dept Environm Engn, TR-10145 Balikesir, Turkey
[2] Uludag Univ, Dept Environm Engn, TR-16059 Bursa, Turkey
关键词
vegetable oil; residual inert COD; physicochemical treatment; dissolved air floatation; oil and grease;
D O I
10.1016/S0032-9592(03)00193-6
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The efficiency of alternative treatment processes in producing a final effluent conforming to regulatory standards with regards to chemical oxygen demand (COD) and oil and grease (O&G) loads was assessed. The study was conducted in three principal stages: waste characterization, lab-scale treatability studies and full-scale applications. The effluent were characterized in terms of pH (6.3-7.2), total COD (13,750-15,000 mg l(-1)), soluble COD (CODs) (6500-7000 mg l(-1)), biochemical oxygen demand (BOD5) (4300-4700 mg l(-1)), O&G (3600-3900 mg l(-1)), total suspended solids (TSS) (3800-4130 mg l(-1)), total Kjeldahl nitrogen (TKN) (636-738 mg l(-1)) and total phosphorus (TP) (61-63 mg l(-1)). After analyzing various raw effluent parameters, lab-scale chemical treatability studies were conducted using Al-2(SO4)(3).18H(2)O and FeCl3.6H(2)O. The results showed 88 and 84% influent COD reduction, while O&G removal was 81 and 93%, respectively. The removal of total suspended solids (TSS) varied from 78 to 86%. Lab-scale aerobic biological treatment reactors with a HRT of 24 h and food to microorganism ratio of 0.3-0.5 were also run to assess the process efficiency and determine the residual soluble COD in the effluent. Residual soluble COD was 59-70 mg l(-1). Based on the results from waste characterization and treatability studies, a continuous full-scale treatment system was constructed and operated in two vegetable oil refining plants with a different pretreatment flow scheme. The overall percentage removal of COD, TSS, and O&G was 92-96, 83-98 and 93-95%, respectively. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:869 / 875
页数:7
相关论文
共 18 条
[1]  
[Anonymous], 1995, STANDARD METHODS EXA
[2]   CURRENT POLLUTION-CONTROL PRACTICES IN THE UNITED-STATES [J].
BOYER, MJ .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1984, 61 (02) :297-301
[3]  
BOYER MJ, 1996, BAILEYS IND OIL FAT, V14
[4]   TREATMENT OF HIGH-STRENGTH ACIDIC WASTEWATER WITH A COMPLETELY MIXED ANAEROBIC FILTER [J].
CHIAN, ESK ;
DEWALLE, FB .
WATER RESEARCH, 1977, 11 (03) :295-304
[5]   PALM OIL REFINERY WASTES TREATMENT [J].
CHIN, KK ;
WONG, KK .
WATER RESEARCH, 1981, 15 (09) :1087-1092
[6]  
Chipasa KB, 2001, POL J ENVIRON STUD, V10, P141
[7]   COMPARATIVE-EVALUATION OF TREATMENT ALTERNATIVES FOR WASTEWATERS FROM AN EDIBLE OIL REFINING INDUSTRY [J].
EROGLU, V ;
OZTURK, I ;
SAN, HA ;
DEMIR, I .
WATER SCIENCE AND TECHNOLOGY, 1990, 22 (09) :225-234
[8]  
GERMIRLI F, 1990, THESIS ITU FEN BILIM
[9]   Deacidifying rice bran oil by solvent extraction and membrane technology [J].
Kale, V ;
Katikaneni, SPR ;
Cheryan, M .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1999, 76 (06) :723-727
[10]   Anaerobic degradation and inhibitory effects of linoleic acid [J].
Lalman, JA ;
Bagley, DM .
WATER RESEARCH, 2000, 34 (17) :4220-4228