Adiabatic RF pulse design for Bloch-Siegert B1+ mapping

被引:16
|
作者
Khalighi, Mohammad Mehdi [1 ]
Rutt, Brian K. [2 ]
Kerr, Adam B. [3 ]
机构
[1] GE Healthcare, Global Appl Sci Lab, Menlo Pk, CA USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Elect Engn, Magnet Resonance Syst Res Lab, Stanford, CA 94305 USA
关键词
B-1(+) mapping; flip angle; Bloch-Siegert shift; off resonance; parallel transmit; adiabatic RF pulse design; STEADY-STATE;
D O I
10.1002/mrm.24507
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The Bloch-Siegert (B-S) B1+ mapping method has been shown to be fast and accurate, yet it suffers from high Specific Absorption Rate (SAR) and moderately long echo time. An adiabatic RF pulse design is introduced here for optimizing the off-resonant B-S RF pulse to achieve more B-S B1+ measurement sensitivity for a given pulse width. The extra sensitivity can be used for higher angle-to-noise ratio B1+ maps or traded off for faster scans. Using numerical simulations and phantom experiments, it is shown that a numerically optimized 2-ms adiabatic B-S pulse is 2.5 times more efficient than a conventional 6-ms Fermi-shaped B-S pulse. The adiabatic B-S pulse performance is validated in a phantom, and in vivo brain B1+ mapping at 3T and 7T are shown. Magn Reson Med 70:829-835, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:829 / 835
页数:7
相关论文
共 40 条
  • [21] Large Dynamic Range Relative B1+ Mapping
    Padormo, Francesco
    Hess, Aaron T.
    Aljabar, Paul
    Malik, Shaihan J.
    Jezzard, Peter
    Robson, Matthew D.
    Hajnal, Joseph V.
    Koopmans, Peter J.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (02) : 490 - 499
  • [22] Fast B1+ mapping using three consecutive RF pulses and balanced gradients for improved bSSFP imaging
    Kim, Min-Oh
    Hong, Taehwa
    Kim, Dong-Hyun
    MAGNETIC RESONANCE IMAGING, 2018, 46 : 40 - 46
  • [23] Encoding methods for B1+ mapping in parallel transmit systems at ultra high field
    Tse, Desmond H. Y.
    Poole, Michael S.
    Magill, Arthur W.
    Felder, Joerg
    Brenner, Daniel
    Shah, N. Jon
    JOURNAL OF MAGNETIC RESONANCE, 2014, 245 : 125 - 132
  • [24] Ultrafast Volumetric B1+ Mapping for Improved Radiofrequency Shimming in 3 Tesla Body MRI
    Sprinkart, Alois M.
    Nehrke, Kay
    Traeber, Frank
    Block, Wolfgang
    Gieseke, Juergen
    Schmitz, Georg
    Willinek, Winfried A.
    Schild, Hans
    Bornert, Peter
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (04) : 857 - 863
  • [25] Complex B1+ mapping with Carr-Purcell spin echoes and its application to electrical properties tomography
    Iyyakkunnel, Santhosh
    Weigel, Matthias
    Ganter, Carl
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (03) : 1250 - 1260
  • [26] A modified multi-echo AFI for simultaneous B1+ magnitude and phase mapping
    Choi, Narae
    Lee, Joonsung
    Kim, Min-Oh
    Shin, Jaewook
    Kim, Dong-Hyun
    MAGNETIC RESONANCE IMAGING, 2014, 32 (04) : 314 - 320
  • [27] Phase-sensitive B1 mapping: Effects of relaxation and RF spoiling
    Wen, Jie
    Sukstanskii, Alexander L.
    Yablonskiy, Dmitriy A.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (01) : 101 - 111
  • [28] Accelerated 3D multi-channel B1+ mapping at 7 T for the brain and heart
    Kent, James L.
    de Buck, Matthijs H. S.
    Dragonu, Iulius
    Chiew, Mark
    Valkovic, Ladislav
    Hess, Aaron T.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (05) : 2007 - 2020
  • [29] Rapid 3D absolute B1+ mapping using a sandwiched train presaturated TurboFLASH sequence at 7 T for the brain and heart
    Kent, James L.
    Dragonu, Iulius
    Valkovic, Ladislav
    Hess, Aaron T.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (03) : 964 - 976
  • [30] Fast 3D 31P B1+ mapping with a weighted stack of spiral trajectory at 7 T
    Widmaier, Mark Stephan
    Kaiser, Antonia
    Baup, Salome
    Wenz, Daniel
    Pierzchala, Katarzyna
    Xiao, Ying
    Huang, Zhiwei
    Jiang, Yun
    Xin, Lijing
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (02) : 481 - 489