Continuous glucose monitoring. Utility and indications

被引:0
|
作者
Litwak, Leon E. [1 ]
Querzoli, Ivanna [2 ]
Musso, Carla [3 ]
Dain, Alejandro [4 ]
Houssay, Solange [4 ]
Proietti, Adrian [5 ]
Costa Gil, Jose E. [5 ]
机构
[1] Hosp Italiano Buenos Aires, Serv Endocrinol Metab & Med Nucl, Buenos Aires, DF, Argentina
[2] Sanofi, Dept Med, Buenos Aires, DF, Argentina
[3] Fdn Favaloro, Diabet, Buenos Aires, DF, Argentina
[4] Hosp Tornu, Buenos Aires, DF, Argentina
[5] Univ Favaloro, Fac Ciencias Med, Buenos Aires, DF, Argentina
关键词
diabetes mellitus; capillary glucose self-monitoring; continuous glucose monitoring; insulin; CLINICAL DECISION-MAKING; BLOOD-GLUCOSE; GLYCEMIC CONTROL; DIABETES CARE; MICROVASCULAR COMPLICATIONS; PUMP THERAPY; TYPE-1; SYSTEM; ASSOCIATION; ADULTS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
An adequate glycemic control prevents and/or delays the development and/or progression of chronic complications in patients with diabetes mellitus (DM). To achieve this control, it is necessary to adjust insulin doses, in type 1 or insulinized type 2 DM persons, based on traditional capillary glucose self-monitoring, which has limitations to generate an adequate data record, is invasive and has low adherence. In contrast, new continuous glucose monitoring (CGM) systems provide more complete and dynamic information, and better compliance. In these systems, a subcutaneous sensor continuously sends glucose values which are captured and stocked by a receptor module. Real-time models (CGMRT) allow continuous and real-time readings of interstitial glucose, whereas CGM-Flash/EI systems require lector approach to sensor module performing intermittent scanning. CGM shows if glycemic levels are increasing or decreasing and how fast it is happening (tendency). CGM decreases glycosylated hemoglobin between 0.53% and 1.0%, as well as time in hypoglycemia by 38%, increasing the time in range of glucose levels, in patients with high adherence. The objectives of this review are to describe the glycemic homeostasis, to evaluate the accuracy of the CGM to interpret the data adequately and finally, based on the information provided by these novel monitoring systems, to suggest a practical way to be added to the traditional intensive insulin therapy.
引用
收藏
页码:44 / 52
页数:9
相关论文
共 50 条
  • [21] Importance of continuous glucose monitoring in the treatment of diabetes mellitus
    Moon, Sun Joon
    Lee, Won-Young
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2023, 66 (07): : 432 - 438
  • [22] Standardizing Reporting of Glucose and Insulin Data for Patients on Multiple Daily Injections Using Connected Insulin Pens and Continuous Glucose Monitoring
    Rodbard, David
    Garg, Satish K.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (03) : 221 - 226
  • [23] The role of continuous glucose monitoring in pregnancy
    Li, Adrian
    Brackenridge, Anna
    OBSTETRIC MEDICINE, 2022, 15 (01) : 6 - 10
  • [24] Continuous Glucose Monitoring and Physical Activity
    Schubert-Olesen, Oliver
    Kroeger, Jens
    Siegmund, Thorsten
    Thurm, Ulrike
    Halle, Martin
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (19)
  • [25] Nontraditional Uses of Continuous Glucose Monitoring
    Kapsar, Paul
    Chao, Christy
    Walker, Tomas
    JNP- THE JOURNAL FOR NURSE PRACTITIONERS, 2023, 19 (03):
  • [26] The Use of Continuous Glucose Monitoring in Patients with Type 2 Diabetes
    Meade, Lisa T.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2012, 14 (02) : 190 - 195
  • [27] Novel Therapeutic Options with Continuous Glucose Monitoring - Practical Recommendations
    Seufert, Jochen
    Deiss, Dorothee
    Goelz, Stefan
    Haak, Thomas
    Klausmann, Gerhard
    Kroeger, Jens
    Lobmann, Ralf
    Pfeiffer, Andreas F. H.
    Schnell, Oliver
    Seibold, Alexander
    Siegmund, Thorsten
    Ziegler, Ralph
    DIABETOLOGIE UND STOFFWECHSEL, 2019, 14 (05) : 388 - 398
  • [28] Continuous glucose monitoring to assess glucose variability in type 3c diabetes
    Lee, Victoria T. Y.
    Poynten, Ann
    Depczynski, Barbara
    DIABETIC MEDICINE, 2022, 39 (08)
  • [29] The Calculation of the Glucose Management Indicator Is Influenced by the Continuous Glucose Monitoring System and Patient Race
    Angellotti, Edith
    Muppavarapu, Sangeetha
    Siegel, Richard D.
    Pittas, Anastassios G.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (09) : 651 - 657
  • [30] Spanish Translation and Linguistic Validation of the Glucose Monitoring Experiences Questionnaire (GME-Q) in Continuous Glucose Monitoring Users
    Beato-Vibora, Pilar I.
    Lazaro-Martin, Lucia
    Gallego-Gamero, Fabiola
    Ambrojo-Lopez, Ana
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (04): : 934 - 938