Flow modification in canine intracranial aneurysm model by an asymmetric stent: studies using digital subtraction angiography (DSA) and image-based computational fluid dynamics (CFD) analyses

被引:7
作者
Hoi, Yiemeng [1 ,4 ]
Ionita, Ciprian N. [1 ]
Tranquebar, Rekha V. [1 ]
Hoffmann, Kenneth R. [1 ,3 ,4 ,5 ,6 ]
Woodward, Scott H. [1 ,4 ]
Taulbee, Dale B. [4 ]
Meng, Hui [1 ,4 ,5 ]
Rudin, Stephen [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] SUNY Buffalo, Toshiba Stroke Res Ctr, Buffalo, NY 14214 USA
[2] SUNY Buffalo, Dept Radiol, Buffalo, NY 14214 USA
[3] SUNY Buffalo, Dept Physiol & Biophys, Buffalo, NY 14214 USA
[4] SUNY Buffalo, Dept Mech & Aerosp Engn, Buffalo, NY 14214 USA
[5] SUNY Buffalo, Dept Neurosurg, Buffalo, NY 14214 USA
[6] SUNY Buffalo, Dept Phys, Buffalo, NY 14214 USA
来源
MEDICAL IMAGING 2006: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES PTS 1 AND 2 | 2006年 / 6143卷
基金
美国国家科学基金会;
关键词
stent; Aneurysm; Digital Subtraction Angiography; Computational Fluid Dynamics; Image guided interventions; CT; image-based finite element models of physiology; image-based biomechanical models; circulation; porosity; wall shear stress;
D O I
10.1117/12.650624
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An asymmetric stent with low porosity patch across the intracranial aneurysm neck and high porosity elsewhere is designed to modify the flow to result in thrombogenesis and occlusion of the aneurysm and yet to reduce the possibility of also occluding adjacent perforator vessels. The purposes of this study are to evaluate the flow field induced by an asymmetric stent using both numerical and digital subtraction angiography (DSA) methods and to quantify the flow dynamics of an asymmetric stent in an in vivo aneurysm model. We created a vein-pouch aneurysm model on the canine carotid artery. An asymmetric stent was implanted at the aneurysm, with 25% porosity across the aneurysm neck and 80% porosity elsewhere. The aneurysm geometry, before and after stent implantation, was acquired using cone beam CT and reconstructed for computational fluid dynamics (CFD) analysis. Both steady-state and pulsatile flow conditions using the measured waveforms from the aneurysm model were studied. To reduce computational costs, we modeled the asymmetric stent effect by specifying a pressure drop over the layer across the aneurysm orifice where the low porosity patch was located. From the CFD results, we found the asymmetric stent reduced the inflow into the aneurysm by 51%, and appeared to create a stasis-like environment which favors thrombus formation. The DSA sequences also showed substantial flow reduction into the aneurysm. Asymmetric stents may be a viable image guided intervention for treating intracranial aneurysms with desired flow modification features.
引用
收藏
页数:10
相关论文
共 38 条
[1]   Modeling of flow in a straight stented and nonstented side wall aneurysm model [J].
Aenis, M ;
Stancampiano, AP ;
Wakhloo, AK ;
Lieber, BB .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (02) :206-212
[2]   Flow changes caused by the sequential placement of stents across the neck of sidewall cerebral aneurysms [J].
Cantón, G ;
Levy, DI ;
Lasheras, JC ;
Nelson, PK .
JOURNAL OF NEUROSURGERY, 2005, 103 (05) :891-902
[4]  
GEREMIA G, 1994, AM J NEURORADIOL, V15, P1223
[5]   EXPERIMENTAL PRODUCTION OF CAROTID ANEURYSMS [J].
GERMAN, WJ ;
BLACK, SPW .
NEW ENGLAND JOURNAL OF MEDICINE, 1954, 250 (03) :104-106
[6]   Treatment of large and giant fusiform intracranial aneurysms with Guglielmi detachable coils [J].
Gobin, YP ;
Vinuela, F ;
Gurian, JH ;
Guglielmi, G ;
Duckwiler, GR ;
Massoud, TF ;
Martin, NA .
JOURNAL OF NEUROSURGERY, 1996, 84 (01) :55-62
[7]   Clinical and angiographic results of endosaccular coiling treatment of giant and very large intracranial aneurysms: A 7-year, single-center experience [J].
Gruber, A ;
Killer, M ;
Bavinzski, G ;
Richling, B .
NEUROSURGERY, 1999, 45 (04) :793-803
[8]   Chronic shunt-dependent hydrocephalus after early surgical and early endovascular treatment of ruptured intracranial aneurysms [J].
Gruber, A ;
Reinprecht, A ;
Bavinzski, G ;
Czech, T ;
Richling, B .
NEUROSURGERY, 1999, 44 (03) :503-509
[9]   Percutaneous intracranial stent placement for aneurysms [J].
Han, PP ;
Albuquerque, FC ;
Ponce, FA ;
MacKay, CI ;
Zabramski, JM ;
Spetzler, RF ;
McDougall, CG .
JOURNAL OF NEUROSURGERY, 2003, 99 (01) :23-30
[10]   ANEURYSM RECURRENCE FOLLOWING ENDOVASCULAR BALLOON OCCLUSION [J].
HEILMAN, CB ;
KWAN, ESK ;
WU, JK .
JOURNAL OF NEUROSURGERY, 1992, 77 (02) :260-264