Dove prism based rotating dual beam bidirectional Doppler OCT

被引:38
作者
Blatter, Cedric [1 ]
Coquoz, Severine [1 ]
Grajciar, Branislav [1 ]
Singh, Amardeep S. G. [1 ]
Bonesi, Marco [1 ]
Werkmeister, Rene M. [1 ]
Schmetterer, Leopold [1 ]
Leitgeb, Rainer A. [1 ]
机构
[1] Med Univ Vienna, Ctr Med Phys & Biomed Engn, A-1090 Vienna, Austria
来源
BIOMEDICAL OPTICS EXPRESS | 2013年 / 4卷 / 07期
关键词
OPTICAL COHERENCE TOMOGRAPHY; RETINAL-BLOOD-FLOW; HIGH-SPEED; VELOCITY; SYSTEM;
D O I
10.1364/BOE.4.001188
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Traditional Doppler OCT is highly sensitive to motion artifacts due to the dependence on the Doppler angle. This limits its accuracy in clinical practice. To overcome this limitation, we use a bidirectional dual beam technique equipped with a novel rotating scanning scheme employing a Dove prism. The volume is probed from two distinct illumination directions with variable controlled incidence plane, allowing for reconstruction of the true flow velocity at arbitrary vessel orientations. The principle is implemented with Swept Source OCT at 1060nm with 100,000 A-Scans/s. We apply the system to resolve pulsatile retinal absolute blood velocity by performing segment scans around the optic nerve head and circumpapillary scan time series. (C) 2013 Optical Society of America
引用
收藏
页码:1188 / 1203
页数:16
相关论文
共 48 条
  • [1] Quantification of a three-dimensional velocity vector using spectral-domain Doppler optical coherence tomography
    Ahn, Yeh-Chan
    Jung, Woonggyu
    Chen, Zhongping
    [J]. OPTICS LETTERS, 2007, 32 (11) : 1587 - 1589
  • [2] Ultrahigh sensitive optical microangiography for in vivo imaging of microcirculations within human skin tissue beds
    An, Lin
    Qin, Jia
    Wang, Ruikang K.
    [J]. OPTICS EXPRESS, 2010, 18 (08): : 8220 - 8228
  • [3] [Anonymous], 2008, OPTICAL COHERENCE TO
  • [4] Total retinal blood flow measurement with ultrahigh speed swept source/Fourier domain OCT
    Baumann, Bernhard
    Potsaid, Benjamin
    Kraus, Martin F.
    Liu, Jonathan J.
    Huang, David
    Hornegger, Joachim
    Cable, Alex E.
    Duker, Jay S.
    Fujimoto, James G.
    [J]. BIOMEDICAL OPTICS EXPRESS, 2011, 2 (06): : 1539 - 1552
  • [5] Ultrahigh-speed non-invasive widefield angiography
    Blatter, Cedric
    Klein, Thomas
    Grajciar, Branislav
    Schmoll, Tilman
    Wieser, Wolfgang
    Andre, Raphael
    Huber, Robert
    Leitgeb, Rainer A.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (07)
  • [6] Angiography of the retina and the choroid with phase-resolved OCT using interval-optimized backstitched B-scans
    Braaf, Boy
    Vermeer, Koenraad A.
    Vienola, Kari V.
    de Boer, Johannes F.
    [J]. OPTICS EXPRESS, 2012, 20 (18): : 20516 - 20534
  • [7] Phase-stabilized optical frequency domain imaging at 1-μm for the measurement of blood flow in the human choroid
    Braaf, Boy
    Vermeer, Kocnraad A.
    Sicam, Victor Arni D. P.
    van Zeeburg, Elsbeth
    van Meurs, Jan C.
    de Boer, Johannes F.
    [J]. OPTICS EXPRESS, 2011, 19 (21): : 20886 - 20903
  • [8] Three-dimensional pointwise comparison of human retinal optical property at 845 and 1060 nm using optical frequency domain imaging
    Chen, Yueli
    Burnes, Daina L.
    de Bruin, Martijn
    Mujat, Mircea
    de Boer, Johannes F.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (02)
  • [9] Measurement of pulsatile total blood flow in the human and rat retina with ultrahigh speed spectral/Fourier domain OCT
    Choi, WooJhon
    Baumann, Bernhard
    Liu, Jonathan J.
    Clermont, Allen C.
    Feener, Edward P.
    Duker, Jay S.
    Fujimoto, James G.
    [J]. BIOMEDICAL OPTICS EXPRESS, 2012, 3 (05): : 1047 - 1061
  • [10] Real-time phase-resolved optical coherence tomography and optical Doppler tomography
    Ding, ZH
    Zhao, YH
    Ren, HW
    Nelson, JS
    Chen, ZP
    [J]. OPTICS EXPRESS, 2002, 10 (05): : 236 - 245