Independent verification of gantry angle for pre-treatment VMAT QA using EPID

被引:17
作者
Adamson, Justus [1 ]
Wu, Qiuwen [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27707 USA
关键词
MODULATED ARC THERAPY; DOSIMETRIC VERIFICATION; QUALITY-ASSURANCE; IMRT; RADIATION; DELIVERY; IMAT; TOOL;
D O I
10.1088/0031-9155/57/20/6587
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We propose a method to incorporate independent verification of gantry angle for electronic portal imaging device (EPID)-based pre-treatment quality assurance (QA) of clinical volumetric modulated arc therapy (VMAT) plans. Gantry angle is measured using projections in the EPID of a custom phantom placed on the couch and the treatment plan is modified so as to be incident on the phantom with a portion of the beam that is collimated in the clinical plan. For our implementation, collimator and couch angles were set to zero and the inferior jaw and two most inferior multi-leaf collimator pairs were opened for the entire QA delivery. A phantom containing five gold coils was used to measure the gantry rotation through which each portal image was acquired. We performed the EPID QA for ten clinical plans and evaluated accuracy of gantry angle measurement, scatter incident on the imager due to the phantom, inter-image pixel linearity and inter-and intra-image noise. The gantry angle could be measured to within 0.0 +/- 0.3 degrees for static gantry and 0.2 +/- 0.2 degrees for arc acquisitions. Scatter due to the presence of the phantom was negligible. The procedure was shown to be feasible and adds gantry angle to the treatment planning parameters that can be verified by EPID-based pre-treatment VMAT QA.
引用
收藏
页码:6587 / 6600
页数:14
相关论文
共 50 条
  • [41] Dosimetric impacts of gantry angle misalignment on prostate cancer treatment using helical tomotherapy
    Su, Fan-Chi
    Shi, Chengyu
    Crownover, Richard
    Swanson, Gregory
    Papanikolaou, Niko
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2008, 7 (04) : 287 - 293
  • [42] Pre-treatment and in-vivo dosimetry of Helical Tomotherapy treatment plans using the Dosimetry Check system
    Mezzenga, E.
    Cagni, E.
    Botti, A.
    Orlandi, M.
    Iori, M.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [43] Evaluation of SRS MapCHECK with StereoPHAN phantom as a new pre-treatment system verification for SBRT plans
    Sadowski, Bartlomiej Mieszko
    Fillmann, Marta
    Szalkowski, Dariusz
    Kukolowicz, Pawel
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2022, 28 (02): : 84 - 89
  • [44] Predicting VMAT patient-specific QA results using a support vector classifier trained on treatment plan characteristics and linac QC metrics
    Granville, Dal A.
    Sutherland, Justin G.
    Belec, Jason G.
    La Russa, Daniel J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (09)
  • [45] Characterization and clinical evaluation of a novel 2D detector array for conventional and flattening filter free (FFF) IMRT pre-treatment verification
    Sekar, Yuvaraj
    Thoelking, Johannes
    Eckl, Miriam
    Kalichava, Irakli
    Sihono, Dwi Seno Kuncoro
    Lohr, Frank
    Wenz, Frederik
    Wertz, Hansjoerg
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2018, 28 (02): : 134 - 141
  • [46] Evaluation of 3D pre-treatment verification for volumetric modulated arc therapy plan in head region
    Ruangchan, S.
    Oonsiri, S.
    Suriyapee, S.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [47] Chasing Zero Harm in Radiation Oncology: Using Pre-treatment Peer Review
    Vijayakumar, Srinivasan
    Duggar, William Neil
    Packianathan, Satya
    Morris, Bait
    Yang, Chunli Claus
    FRONTIERS IN ONCOLOGY, 2019, 9
  • [48] Transduction of ferret airway epithelia using a pre-treatment and lentiviral gene vector
    Cmielewski, Patricia
    Farrow, Nigel
    Donnelley, Martin
    McIntyre, Chantelle
    Penny-Dimri, Jahan
    Kuchel, Tim
    Parsons, David
    BMC PULMONARY MEDICINE, 2014, 14
  • [49] Investigating the effectiveness of monitoring relevant variations during IMRT and VMAT treatments by EPID-based 3D in vivo verification performed using planning CTs
    Li, Yinghui
    Zhu, Jinhan
    Shi, Jinping
    Chen, Lixin
    Liu, Xiaowei
    PLOS ONE, 2019, 14 (06):
  • [50] 4D Monte Carlo dose calculations for pre-treatment quality assurance of VMAT SBRT: a phantom-based feasibility study
    Roberts, Natalia F.
    Williams, Matthew
    Holloway, Lois
    Metcalfe, Peter
    Oborn, Bradley M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (21)