Independent verification of gantry angle for pre-treatment VMAT QA using EPID

被引:17
作者
Adamson, Justus [1 ]
Wu, Qiuwen [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27707 USA
关键词
MODULATED ARC THERAPY; DOSIMETRIC VERIFICATION; QUALITY-ASSURANCE; IMRT; RADIATION; DELIVERY; IMAT; TOOL;
D O I
10.1088/0031-9155/57/20/6587
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We propose a method to incorporate independent verification of gantry angle for electronic portal imaging device (EPID)-based pre-treatment quality assurance (QA) of clinical volumetric modulated arc therapy (VMAT) plans. Gantry angle is measured using projections in the EPID of a custom phantom placed on the couch and the treatment plan is modified so as to be incident on the phantom with a portion of the beam that is collimated in the clinical plan. For our implementation, collimator and couch angles were set to zero and the inferior jaw and two most inferior multi-leaf collimator pairs were opened for the entire QA delivery. A phantom containing five gold coils was used to measure the gantry rotation through which each portal image was acquired. We performed the EPID QA for ten clinical plans and evaluated accuracy of gantry angle measurement, scatter incident on the imager due to the phantom, inter-image pixel linearity and inter-and intra-image noise. The gantry angle could be measured to within 0.0 +/- 0.3 degrees for static gantry and 0.2 +/- 0.2 degrees for arc acquisitions. Scatter due to the presence of the phantom was negligible. The procedure was shown to be feasible and adds gantry angle to the treatment planning parameters that can be verified by EPID-based pre-treatment VMAT QA.
引用
收藏
页码:6587 / 6600
页数:14
相关论文
共 50 条
  • [21] An investigation of the IQM signal variation and error detection sensitivity for patient specific pre-treatment QA
    Alharthi, Thahabah
    George, Armia
    Arumugam, Sankar
    Holloway, Lois
    Thwaites, David
    Vial, Phil
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 86 : 6 - 18
  • [22] Sensitivity and specificity of Varian Halcyon's portal dosimetry for plan-specific pre-treatment QA
    Razinskas, Gary
    Schindhelm, Robert
    Sauer, Otto A.
    Wegener, Sonja
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (08):
  • [23] Pre-treatment verification of intensity modulated radiation therapy plans using a commercial electronic portal dosimetry system
    Kathleen J. Roxby
    Jeffrey C. Crosbie
    Australasian Physical & Engineering Sciences in Medicine, 2010, 33 : 51 - 57
  • [24] Development of a new VMAT QA framework for Mobius3D using control-point specific EPID images
    Seok, Jaehyun
    Kim, Hojin
    Han, Min Cheol
    Kim, Jihun
    Park, Kwangwoo
    Cho, Hyeonjeong
    Yoo, Dohyeon
    Kim, Jin Sung
    FRONTIERS IN ONCOLOGY, 2024, 14
  • [25] Application of TG-218 action limits to SRS and SBRT pre-treatment patient specific QA
    Xia, Yuqing
    Adamson, Justus
    Zlateva, Yana
    Giles, Will
    JOURNAL OF RADIOSURGERY AND SBRT, 2020, 7 (02): : 135 - 147
  • [26] Pre-treatment verification of intensity modulated radiation therapy plans using a commercial electronic portal dosimetry system
    Roxby, Kathleen J.
    Crosbie, Jeffrey C.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2010, 33 (01) : 51 - 57
  • [27] Gantry angle-dependent correction of dose detection error due to panel position displacement in IMRT dose verification using EPIDs
    Jin, Guang-hua
    Zhu, Jin-han
    Chen, Li-xin
    Deng, Xiao-wu
    Huang, Bo-tian
    Yuan, Ke
    Liu, Xiao-wei
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (02): : 209 - 214
  • [28] Multicentre validation of IMRT pre-treatment verification: Comparison of in-house and external audit
    Jornet, Nuria
    Carrasco, Pablo
    Beltran, Merce
    Francisco Calvo, Juan
    Escude, Lluis
    Hernandez, Victor
    Quera, Jaume
    Saez, Jordi
    RADIOTHERAPY AND ONCOLOGY, 2014, 112 (03) : 381 - 388
  • [29] Comparison of gamma analysis with using different dosimetric systems for pre-treatment verification of intensity-modulated radiation therapy
    Inan, Gokcen
    Gul, Osman Vefa
    CANADIAN JOURNAL OF PHYSICS, 2021, 99 (05) : 390 - 396
  • [30] Is it still necessary to perform measured based pre-treatment patient-specific QA for SRS HyperArc treatments?
    Cavalli, Nina
    Bonanno, Elisa
    Borzi, Giuseppina R.
    D'Anna, Alessia
    Pace, Martina
    Stella, Giuseppe
    Zirone, Lucia
    Marino, Carmelo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (02):