Pre-treatment of Llobregat River raw water through pressurised inside/out hollow fibre ultrafiltration membranes

被引:6
作者
Ferrer, O. [1 ]
Serrallach, X. [1 ]
Horvath, F. [2 ]
Mesa, J. [3 ]
Gibert, O. [1 ,4 ]
Bernat, X. [1 ]
机构
[1] CETaqua, Water Technol Ctr, Cornella Del Llobregat 08940, Spain
[2] Pentair Water Proc Technol BV, Pentair X Flow, NL-757547 Tc Enschede, Netherlands
[3] SGAB, Barcelona 08018, Spain
[4] Univ Politecn Cataluna, Dept Engn Quim, ETSEIB, E-08028 Barcelona, Spain
关键词
Direct ultrafiltration; Membrane fouling; Low and variable quality surface water; Drinking water treatment; MODIFIED FOULING INDEX; NANOFILTRATION MEMBRANES; UF/MF PRETREATMENT; CAKE RESISTANCE; RESERVOIR WATER; DRINKING-WATER; FILTRATION; NOM; COAGULATION; PARTICLES;
D O I
10.1080/19443994.2012.714637
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The feasibility of raw river direct ultrafiltration, as an alternative to conventional drinking water treatment plant pre-treatment, was investigated at prototype scale (May-October 2011). A highly variable and challenging water resource was selected, in order to assess different scenarios, covering a broad range of conditions. The prototype was able to deal with conditions ranging from 20 to > 800NTU successfully, without any chemical pre-treatment and consuming low amount of chemical reagents for cleaning purposes. The membranes' performance proved to work better in terms of water production yield and resistance build up stability at medium and high turbidity episodes than at lower ones, probably due to a cake layer formation which prevented small binding organic species and particles reaching the membrane. Permeate quality, both in physico-chemical and microbiological terms, was independent of the feed water characteristics.
引用
收藏
页码:1831 / 1837
页数:7
相关论文
共 35 条
  • [1] SDI normalization and alternatives
    Alhadidi, A.
    Kemperman, A. J. B.
    Schippers, J. C.
    Blankert, B.
    Wessling, M.
    van der Meer, W. G. J.
    [J]. DESALINATION, 2011, 279 (1-3) : 390 - 403
  • [2] [Anonymous], 1995, AQUATIC CHEM
  • [3] Transparent exopolymer particles: Potential agents for organic fouling and biofilm formation in desalination and water treatment plants
    Bar-Zeev, Edo
    Berman-Frank, Ilana
    Liberman, Boris
    Rahav, Eyal
    Passow, Uta
    Berman, Tom
    [J]. DESALINATION AND WATER TREATMENT, 2009, 3 (1-3) : 136 - 142
  • [4] The modified fouling index using ultrafiltration membranes (MFI-UF): characterisation, filtration mechanisms and proposed reference membrane
    Boerlage, SFE
    Kennedy, MD
    Dickson, MR
    El-Hodali, DEY
    Schippers, JC
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2002, 197 (1-2) : 1 - 21
  • [5] Boerlage SFE, 1998, DESALINATION, V118, P131
  • [6] The fouling of microfiltration membranes by NOM after coagulation treatment
    Carroll, T
    King, S
    Gray, SR
    Bolto, BA
    Booker, NA
    [J]. WATER RESEARCH, 2000, 34 (11) : 2861 - 2868
  • [7] Chen KL, 2006, ENVIRON SCI TECHNOL, V40, P1516, DOI 10.1021/es0518068
  • [8] The effect of coagulation with MF/UF membrane filtration for the removal of virus in drinking water
    Fiksdal, Liv
    Leiknes, TorOve
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2006, 279 (1-2) : 364 - 371
  • [9] Flemming HC, 2001, WATER SCI TECHNOL, V43, P1
  • [10] Membrane fouling control in ultrafiltration technology for drinking water production: A review
    Gao, Wei
    Liang, Heng
    Ma, Jun
    Han, Mei
    Chen, Zhong-lin
    Han, Zheng-shuang
    Li, Gui-bai
    [J]. DESALINATION, 2011, 272 (1-3) : 1 - 8