A novel on-line system for monitoring the oil level of capsule-type storage tank of power transformer

被引:0
|
作者
Li, Shilong [1 ]
Zhang, Chengxi [1 ]
Xu, Datian [1 ]
Pan, Yan [1 ]
Ni, Jingwen [1 ]
Qiao, Yaxing [1 ]
机构
[1] State Grid Shanghai Municipal Elect Power Co, Shanghai, Peoples R China
关键词
transformer; oil level; measuring transducer; on-line monitoring system;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The oil level of the power transformer's oil storage tank is an important operation parameter. The oil level sensor based on magnetic resistance circuit and its hardware structure are designed. Based on the communication and monitoring technology of electric Internet of things, an on-line monitoring and control system is developed to realize remote measurement of the oil level. The control and operation personnel can obtain the real-time oil level value in the SCADA system, which improves the operational reliability and reduces the workload of personnel. Once the oil level is too high, too low or descending rapidly, the system will send alarm signals in time to the control and operation personnel to facilitate the timely response and take measures to reduce the probability of failure, which could ensure the safe and stable operation of equipment and power grid.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] On-Line Partial Discharge Monitoring and Diagnostic System for Power Transformer
    林渡
    姜磊
    李福祺
    朱德恒
    谈克雄
    吴成琦
    金显贺
    王昌长
    郑振中
    Tsinghua Science and Technology, 2005, (05) : 598 - 604
  • [2] Design and Implementation of Vibration On-line Monitoring System of Power Transformer
    Xu, C. B.
    Wang, F. H.
    Jin, Z. J.
    2013 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PES), 2013,
  • [3] Research on on-line PD monitoring system for large power transformer
    Ma, WP
    Hao, DZ
    Zheng, LH
    Wang, S
    1998 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, PROCEEDINGS, 1998, : 505 - 508
  • [4] The application analysis of the on-line monitoring system of dissolved gas in transformer oil
    Li Yanming
    Liu Gang
    Liang Ying
    Xing Yan
    2007 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2007, : 747 - +
  • [5] On-line multi-sensor monitoring system for insulation condition of oil-immersed power transformer
    Zhao, WB
    Zhang, GJ
    Sun, Y
    Yan, Z
    Xu, DK
    CONFERENCE RECORD OF THE 2004 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2004, : 89 - 92
  • [6] On-line monitoring and diagnoses of power transformer bushings
    Setayeshmehr, Alireza
    Akbari, Alireza
    Borsi, Hossein
    Gockenbach, Ernst
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2006, 13 (03) : 608 - 615
  • [7] On-line monitoring of the static electrification in power transformer
    Li, FX
    Qi, ZS
    Huang, H
    JOINT CONFERENCE OF 96' AICDEI / 4T-JCCEID, 1996, : 397 - 400
  • [8] Development of an on-line remote monitoring and fault diagnosing system for power transformer
    Wang, Juan
    Hu, Hongsheng
    Qian, Suxiang
    Cao, Jian
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING AND MECHANICS 2007, VOLS 1 AND 2, 2007, : 636 - 641
  • [9] Development of an on-line state monitoring and fault diagnosis system for power transformer
    Hu Hongsheng
    Qian Suxiang
    Wang Juan
    Cao Han
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 3113 - 3116
  • [10] Performance estimation simulation of capsule-type thermal energy storage system (in-line arranged cylindrical capsules)
    Ishikawa, M.
    Hirata, T.
    Tamaki, H.
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 1996, 62 (597): : 2005 - 2012