Longitudinal in vivo imaging of bone formation and resorption using fluorescence molecular tomography

被引:15
作者
Lambers, F. M. [1 ]
Stuker, F. [2 ]
Weigt, C. [1 ]
Kuhn, G. [1 ]
Koch, K. [1 ]
Schulte, F. A. [1 ]
Ripoll, J. [3 ]
Rudin, M. [2 ]
Mueller, R. [1 ]
机构
[1] Swiss Fed Inst Technol, Inst Biomech, CH-8093 Zurich, Switzerland
[2] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[3] Fdn Res & Technol Hellas FORTH, Inst Elect Struct & Laser, Iraklion, Crete, Greece
关键词
Multimodality imaging; Fluorescence molecular tomography; In vivo micro-computed tomography; Dynamic bone morphometry; Bone; NONINVASIVE OPTICAL-DETECTION; FUNCTIONAL ADAPTATION; OSTEOGENIC RESPONSE; CANCELLOUS BONE; TAIL VERTEBRAE; CORTICAL BONE; NITRIC-OXIDE; REPRODUCIBILITY; VALIDATION; STIMULATION;
D O I
10.1016/j.bone.2012.11.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Bone research often focuses on anatomical imaging of the bone microstructure, but in order to gain better understanding in how bone remodeling is modulated through interventions also bone formation and resorption processes should be investigated. With this in mind, the purpose of this study was to establish a longitudinal in vivo imaging approach of bone formation and resorption using fluorescence molecular tomography (FMT). In this study the reproducibility, accuracy and sensitivity of FMT for bone imaging were assessed by performing longitudinal measurements with FMT and comparing it to in vivo micro-computed tomography on a set of control mice, and mice in which load-adaptation was induced in the sixth caudal vertebra. The precision error for FMT measurements, expressed as coefficient of variation, was smaller than 16%, indicating acceptable reproducibility. A correlation was found between bone resorption measured with FMT and bone resorption rate measured with in vivo micro-computed tomography only over the first 14 days (R = 0.81, p<0.01), but not between bone formation measured with FMT and bone formation rate measured with in vivo micro-CT. Bone formation measured by FMT was 89-109% greater (p<0.05) for mice subjected to mechanical loading than control mice. Bone resorption was 5-8% lower, but did not reach a significant difference between groups, indicating moderate sensitivity for FMT. In conclusion, in vivo FMT in mouse tail bones is feasible but needs to be optimized for monitoring load adaptation in living mice. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:587 / 595
页数:9
相关论文
共 50 条
[41]   Comparison of photoacoustic and fluorescence tomography for the in vivo imaging of ICG-labelled liposomes in the medullary cavity in mice [J].
Humbert, Jana ;
Will, Olga ;
Penate-Medina, Tuula ;
Penate-Medina, Oula ;
Jansen, Olav ;
Both, Marcus ;
Glueer, Claus-Christian .
PHOTOACOUSTICS, 2020, 20
[42]   360° free space Fluorescence Molecular Tomography using silhouette surface reconstruction [J].
Lasser, T. ;
Deliolanis, N. ;
Soubret, A. ;
Ripoll, J. ;
Ntziachristos, V. .
DIFFUSE OPTICAL IMAGING OF TISSUE, 2007, 6629
[43]   In vivo quantitative imaging biomarkers of bone quality and mineral density using multi-band-SWIFT magnetic resonance imaging [J].
Surowiec, Rachel K. ;
Ram, Sundaresh ;
Idiyatullin, Djaudat ;
Goulet, Robert ;
Schlecht, Stephen H. ;
Galban, Craig J. ;
Kozloff, Kenneth M. .
BONE, 2021, 143
[44]   Mechanoregulation analysis of bone formation in tissue engineered constructs requires a volumetric method using time-lapsed micro-computed tomography [J].
Griesbach, Julia K. ;
Schulte, Friederike A. ;
Schaedli, Gian Nutal ;
Rubert, Marina ;
Muller, Ralph .
ACTA BIOMATERIALIA, 2024, 179 :149-163
[45]   Three-dimensional microcomputed tomography imaging of basic multicellular unit-related resorption spaces in human cortical bone [J].
Cooper, David M. L. ;
Thomas, C. David L. ;
Clement, John G. ;
Hallgrimsson, Benedikt .
ANATOMICAL RECORD PART A-DISCOVERIES IN MOLECULAR CELLULAR AND EVOLUTIONARY BIOLOGY, 2006, 288A (07) :806-816
[46]   Reconstruction of fluorophore absorption and fluorescence lifetime using early photon mesoscopic fluorescence molecular tomography: a phantom study [J].
Konovalov, Alexander B. ;
Vlasov, Vitaly V. ;
Samarin, Sergei I. ;
Soloviev, Ilya D. ;
Savitsky, Alexander P. ;
Tuchin, Valery V. .
JOURNAL OF BIOMEDICAL OPTICS, 2022, 27 (12)
[47]   Molecular Imaging of Atheroma Components in vivo Using Targeted Echogenic Immunoliposomes [J].
Kim, Hyunggun ;
Rim, Yonghoon ;
Kee, Patrick ;
Moody, Melanie R. ;
Klegerman, Melvin E. ;
Huang, Shao-Ling ;
McPherson, David D. ;
Laing, Susan T. .
CIRCULATION, 2012, 126 (21)
[48]   Anatomical image-guided fluorescence molecular tomography reconstruction using kernel method [J].
Baikejiang, Reheman ;
Zhao, Yue ;
Fite, Brett Z. ;
Ferrara, Katherine W. ;
Li, Changqing .
JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (05)
[49]   Sparse Reconstruction of Fluorescence Molecular Tomography Using Variable Splitting and Alternating Direction Scheme [J].
Ye, Jinzuo ;
Du, Yang ;
An, Yu ;
Mao, Yamin ;
Jiang, Shixin ;
Shang, Wenting ;
He, Kunshan ;
Yang, Xin ;
Wang, Kun ;
Chi, Chongwei ;
Tian, Jie .
MOLECULAR IMAGING AND BIOLOGY, 2018, 20 (01) :37-46
[50]   Sparse Reconstruction of Fluorescence Molecular Tomography Using Variable Splitting and Alternating Direction Scheme [J].
Jinzuo Ye ;
Yang Du ;
Yu An ;
Yamin Mao ;
Shixin Jiang ;
Wenting Shang ;
Kunshan He ;
Xin Yang ;
Kun Wang ;
Chongwei Chi ;
Jie Tian .
Molecular Imaging and Biology, 2018, 20 :37-46