Probing the influence of graphene oxide sheets size on the performance of label-free electrochemical biosensors

被引:29
|
作者
Eissa, Shimaa [1 ,2 ,3 ]
N'diaye, Jeanne [1 ]
Brisebois, Patrick [1 ]
Izquierdo, Ricardo [1 ]
Tavares, Ana C. [2 ]
Siaj, Mohamed [1 ]
机构
[1] Univ Quebec Montreal, Dept Chim & Biochim, QCAM CQMF, NanoQAM, Montreal, PQ H3C 3P8, Canada
[2] Inst Natl Rech Sci Energie Mat & Telecommun, 1650 Boul Lionel Boulet, Varennes, PQ J3X 1S2, Canada
[3] Alfaisal Univ, Dept Chem, Al Zahrawi St,Al Takhassusi Rd, Riyadh 11533, Saudi Arabia
关键词
SENSITIVE DETECTION; CARBON; IMMUNOSENSOR; REDUCTION; INSIGHTS; DENSITY;
D O I
10.1038/s41598-020-70384-5
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The integration of graphene materials into electrochemical biosensing platforms has gained significant interest in recent years. Bulk quantities of graphene can be synthesized by oxidation of graphite to graphite oxide and subsequent exfoliation to graphene oxide (GO). However, the size of the resultant GO sheets changes from the parent graphite yielding a polydispersed solution of sizes ranging from a few nanometers to tens of micrometers. Here, we investigate the direct effect of GO sheets sizes on biosensor performance. We separated different GO sheets sizes, and we characterized them via atomic force, scanning electron, Raman and X-ray photoelectron spectroscopies and solid state nuclear magnetic resonance (NMR). As proof of concept, the sensing performance of these GO samples was probed using a well-known ssDNA aptasensor against microcystin-LR toxin and an immunosensor against beta -lactoglobulin. The resulting aptasensors and immunosensors are fabricated by using covalent attachment and physical adsorption. We found that the aptasensors fabricated using physical adsorption, the binding signal variation was dramatically increased with increasing the GO sheet size. In contrast, for the aptasensor fabricated using covalent immobilization, the binding signal variation decreased with increasing GO sheet size. However, for the beta -lactoglobulin immunosensors, the optimum signals were observed at intermediate GO sheet size. GO sheet size could enhance or inhibit the sensitivity of the graphene-based electrochemical sensors. Our results demonstrate that controlling the size of GO sheets may have a profound impact in specific biosensing applications.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Graphene oxide functionalized long period grating for ultrasensitive label-free immunosensing
    Liu, Chen
    Cai, Qi
    Xu, Baojian
    Zhu, Weidong
    Zhang, Lin
    Zhao, Jianlong
    Chen, Xianfeng
    BIOSENSORS & BIOELECTRONICS, 2017, 94 : 200 - 206
  • [32] Reduced graphene oxide-titania based platform for label-free biosensor
    Solanki, Pratima R.
    Srivastava, Saurabh
    Ali, Md. Azahar
    Srivastava, Rajesh Kr.
    Srivastava, Anchal
    Malhotra, B. D.
    RSC ADVANCES, 2014, 4 (104): : 60386 - 60396
  • [33] Graphene oxide amplified fluorescence anisotropy for label-free detection of potassium ion
    Zhen, Shu Jun
    Yu, Yan
    Li, Chun Mei
    Huang, Cheng Zhi
    ANALYST, 2015, 140 (01) : 353 - 357
  • [34] A label-free electrochemical immunosensor based on multi-functionalized graphene oxide for ultrasensitive detection of microcystin-LR
    Hu, YunXia
    Shang, Fang
    Liu, Yuan
    Wang, Sui
    Hu, Yufang
    Guo, Zhiyong
    CHEMICAL PAPERS, 2018, 72 (01) : 71 - 79
  • [35] Graphene oxide-based electrochemical label-free detection of glycoproteins down to aM level using a lectin biosensor
    Klukova, L.
    Filip, J.
    Belicky, S.
    Vikartovska, A.
    Tkac, J.
    ANALYST, 2016, 141 (14) : 4278 - 4282
  • [36] Bioreceptors' immobilization by hydrogen bonding interactions and differential pulse voltammetry for completely label-free electrochemical biosensors
    Lopez-Marzo, Adaris
    Mas-Torrent, Marta
    MICROCHIMICA ACTA, 2024, 191 (11)
  • [37] Label-free electrochemical aptasensor for thrombin detection based on the nafion@graphene as platform
    Sun, Tao
    Wang, Li
    Li, Na
    Gan, Xianxue
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2011, 34 (09) : 1081 - 1085
  • [38] Physical Structure and Electrochemical Response of Diamond Graphite Nanoplatelets: From CVD Synthesis to Label-Free Biosensors
    Santos, Nuno F.
    Pereira, Sonia O.
    Fernandes, Antonio J. S.
    Vasconcelos, Thiago L.
    Fung, Chung M.
    Archanjo, Braulio S.
    Achete, Carlos A.
    Teixeira, Sofia R.
    Silva, Rui F.
    Costa, Florinda M.
    ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (08) : 8470 - 8482
  • [39] Label-free electrochemical immunosensor for Ochratoxin a detection in coffee samples
    de Oliveira, Jairo Pinto
    Burgos-Florez, Francisco
    Sampaio, Isabella
    Villalba, Pedro
    Zucolotto, Valtencir
    TALANTA, 2023, 260
  • [40] Employment of electrostriction phenomenon for label-free electrochemical immunosensing of tetracycline
    Starzec, Karolina
    Cristea, Cecilia
    Tertis, Mihaela
    Feier, Bogdan
    Wieczorek, Marcin
    Koscielniak, Pawel
    Kochana, Jolanta
    BIOELECTROCHEMISTRY, 2020, 132