Probing the influence of graphene oxide sheets size on the performance of label-free electrochemical biosensors

被引:29
|
作者
Eissa, Shimaa [1 ,2 ,3 ]
N'diaye, Jeanne [1 ]
Brisebois, Patrick [1 ]
Izquierdo, Ricardo [1 ]
Tavares, Ana C. [2 ]
Siaj, Mohamed [1 ]
机构
[1] Univ Quebec Montreal, Dept Chim & Biochim, QCAM CQMF, NanoQAM, Montreal, PQ H3C 3P8, Canada
[2] Inst Natl Rech Sci Energie Mat & Telecommun, 1650 Boul Lionel Boulet, Varennes, PQ J3X 1S2, Canada
[3] Alfaisal Univ, Dept Chem, Al Zahrawi St,Al Takhassusi Rd, Riyadh 11533, Saudi Arabia
关键词
SENSITIVE DETECTION; CARBON; IMMUNOSENSOR; REDUCTION; INSIGHTS; DENSITY;
D O I
10.1038/s41598-020-70384-5
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The integration of graphene materials into electrochemical biosensing platforms has gained significant interest in recent years. Bulk quantities of graphene can be synthesized by oxidation of graphite to graphite oxide and subsequent exfoliation to graphene oxide (GO). However, the size of the resultant GO sheets changes from the parent graphite yielding a polydispersed solution of sizes ranging from a few nanometers to tens of micrometers. Here, we investigate the direct effect of GO sheets sizes on biosensor performance. We separated different GO sheets sizes, and we characterized them via atomic force, scanning electron, Raman and X-ray photoelectron spectroscopies and solid state nuclear magnetic resonance (NMR). As proof of concept, the sensing performance of these GO samples was probed using a well-known ssDNA aptasensor against microcystin-LR toxin and an immunosensor against beta -lactoglobulin. The resulting aptasensors and immunosensors are fabricated by using covalent attachment and physical adsorption. We found that the aptasensors fabricated using physical adsorption, the binding signal variation was dramatically increased with increasing the GO sheet size. In contrast, for the aptasensor fabricated using covalent immobilization, the binding signal variation decreased with increasing GO sheet size. However, for the beta -lactoglobulin immunosensors, the optimum signals were observed at intermediate GO sheet size. GO sheet size could enhance or inhibit the sensitivity of the graphene-based electrochemical sensors. Our results demonstrate that controlling the size of GO sheets may have a profound impact in specific biosensing applications.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Label-free electrochemical aptasensor for detection of Acinetobacter baumannii : Unveiling the kinetic behavior of reduced graphene oxide v/s graphene oxide
    Singhal, Chaitali
    Gupta, Shruti
    Dhingra, Jyoti
    Pandey, Sweta
    Chatterjee, Sudarshana
    Bargakshatriya, Rupa
    Avasthi, Devesh Kumar
    Pramanik, Sumit
    Chaudhuri, Susmita
    ELECTROCHIMICA ACTA, 2024, 492
  • [2] A Bifunctional Nanosilver-Reduced Graphene Oxide Nanocomposite for Label-Free Electrochemical Immunosensing
    Chanarsa, Supakeit
    Jakmunee, Jaroon
    Ounnunkad, Kontad
    FRONTIERS IN CHEMISTRY, 2021, 9
  • [3] Nanophotonic label-free biosensors for environmental monitoring
    Chocarro-Ruiz, Blanca
    Fernandez-Gavela, Adrian
    Herranz, Sonia
    Lechuga, Laura M.
    CURRENT OPINION IN BIOTECHNOLOGY, 2017, 45 : 175 - 183
  • [4] Facile synthesis of cuprous oxide nanowires decorated graphene oxide nanosheets nanocomposites and its application in label-free electrochemical immunosensor
    Wang, Huan
    Zhang, Yong
    Wang, Yulan
    Ma, Hongmin
    Du, Bin
    Wei, Qin
    BIOSENSORS & BIOELECTRONICS, 2017, 87 : 745 - 751
  • [5] Sonochemical synthesis of magnetic Fe3O4/graphene nanocomposites for label-free electrochemical biosensors
    Suhanto, Rhesti Nurlina
    Harimurti, Suksmandhira
    Septiani, Ni Luh Wulan
    Utari, Listya
    Anshori, Isa
    Wasisto, Hutomo Suryo
    Suzuki, Hiroaki
    Suyatman
    Yuliarto, Brian
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2020, 31 (18) : 15381 - 15393
  • [6] A graphene oxide-based label-free electrochemical aptasensor for the detection of alpha-fetoprotein
    Yang, Shaohong
    Zhang, Feifei
    Wang, Zonghua
    Liang, Qionglin
    BIOSENSORS & BIOELECTRONICS, 2018, 112 : 186 - 192
  • [7] Label-Free and Regenerative Electrochemical Microfluidic Biosensors for Continual Monitoring of Cell Secretomes
    Shin, Su Ryon
    Kilic, Tugba
    Zhang, Yu Shrike
    Avci, Huseyin
    Hu, Ning
    Kim, Duckjin
    Branco, Cristina
    Aleman, Julio
    Massa, Solange
    Silvestri, Antonia
    Kang, Jian
    Desalvo, Anna
    Hussaini, Mohammed Abdullah
    Chae, Su-Kyoung
    Polini, Alessandro
    Bhise, Nupura
    Hussain, Mohammad Asif
    Lee, HeaYeon
    Dokmeci, Mehmet R.
    Khademhosseini, Ali
    ADVANCED SCIENCE, 2017, 4 (05):
  • [8] Enhanced Plasmonic Biosensors of Hybrid Gold Nanoparticle-Graphene Oxide-Based Label-Free Immunoassay
    Chiu, Nan-Fu
    Chen, Chi-Chu
    Yang, Cheng-Du
    Kao, Yu-Sheng
    Wu, Wei-Ren
    NANOSCALE RESEARCH LETTERS, 2018, 13
  • [9] Label-Free Electrochemical Biosensors for the Determination of Flaviviruses: Dengue, Zika, and Japanese Encephalitis
    Khristunova, Ekaterina
    Dorozhko, Elena
    Korotkova, Elena
    Kratochvil, Bohumil
    Vyskocil, Vlastimil
    Barek, Jiri
    SENSORS, 2020, 20 (16) : 1 - 24
  • [10] Functionalized CVD monolayer graphene for label-free impedimetric biosensing
    Eissa, Shimaa
    Jimenez, Gaston Contreras
    Mahvash, Farzaneh
    Guermoune, Abdeladim
    Tlili, Chaker
    Szkopek, Thomas
    Zourob, Mohammed
    Siaj, Mohamed
    NANO RESEARCH, 2015, 8 (05) : 1698 - 1709