Measurements and modelling of the compliance of human and porcine organs

被引:227
作者
Carter, FJ [1 ]
Frank, TG [1 ]
Davies, PJ [1 ]
McLean, D [1 ]
Cuschieri, A [1 ]
机构
[1] Univ Dundee, Ninewells Hosp & Med Sch, Dept Surg & Mol Oncol, Dundee DD1 9SY, Scotland
基金
英国工程与自然科学研究理事会;
关键词
tissue compliance; human organ compliance; tissue stress-strain measurements; surgical simulation; tissue modelling;
D O I
10.1016/S1361-8415(01)00048-2
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Stress-strain data obtained from animal and human tissue have several applications including medical diagnosis, assisting in surgical instrument design and the production of realistic computer-based simulators for training in minimal access surgery. Such data may also be useful for corroborating mathematical models of tissue response. This paper presents data obtained from ex-vivo and in-vivo tissue indentation tests using a small indentor that is similar to instruments used in minimal access surgery. In addition, uniform stress tests provide basic material property data, via an exponential stress-strain law, to allow a finite element method to be used to predict the response for the non-uniform stresses produced by the small indentor. Data are obtained from harvested pig liver and spleen using a static compliance probe. Data for human liver are obtained from volunteer patients, undergoing minor open surgery, using a sterile hand-held compliance probe. All the results demonstrate highly non-linear stress-strain behaviour. Pig spleen is shown to be much more compliant than pig liver with mean elastic moduli of 0.11 and 4.0 MPa respectively. The right lobe of human liver had a mean elastic modulus of about 0.27 MPa. However, a single case of a diseased liver had a mean modulus of 0.74 MPa - nearly three times the stiffness. It was found that an exponential stress-strain law could accurately fit uniform stress test data and that subsequent finite element modelling for non-uniform stress around a small indentor matched measured force characteristics. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:231 / 236
页数:6
相关论文
共 12 条
  • [1] RESTRUCTED ANIMAL TISSUE MODEL FOR TRAINING IN LAPAROSCOPIC ANTIREFLUX SURGERY
    CARTER, F
    RUSSELL, E
    DUNKLEY, P
    CUSCHIERI, A
    [J]. MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1994, 3 (02): : 77 - 80
  • [2] CARTER FJ, 1996, DARPA PROGR REPORTS
  • [3] INTERACTIVELY DEFORMABLE MODELS FOR SURGERY SIMULATION
    COVER, SA
    EZQUERRA, NF
    OBRIEN, JF
    ROWE, R
    GADACZ, T
    PALM, E
    [J]. IEEE COMPUTER GRAPHICS AND APPLICATIONS, 1993, 13 (06) : 68 - 75
  • [4] Davies PJ, 1999, J THEOR MED, V1, P247
  • [5] DAVIES PJ, 2000, 200015 U STRATHCL
  • [6] ELASTICITY OF SOFT BIOLOGICAL TISSUES
    DEMIRAY, H
    [J]. JOURNAL OF BIOMECHANICS, 1972, 5 (03) : 309 - &
  • [7] DEMIRAY H, 1981, ASME, V103, P73
  • [8] ELASTICITY OF SOFT TISSUES IN SIMPLE ELONGATION
    FUNG, YCB
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1967, 213 (06): : 1532 - +
  • [9] Karduna AR, 1997, ANN BIOMED ENG, V25, P1009
  • [10] PATTERNS OF CARTILAGE STIFFNESS ON NORMAL AND DEGENERATE HUMAN FEMORAL HEADS
    KEMPSON, GE
    SWANSON, SAV
    SPIVEY, CJ
    FREEMAN, MAR
    [J]. JOURNAL OF BIOMECHANICS, 1971, 4 (06) : 597 - &