Assessment of corneal hydration sensing in the terahertz band: in vivo results at 100 GHz

被引:37
作者
Bennett, David [1 ]
Taylor, Zachary [1 ]
Tewari, Pria [1 ]
Sung, Sijun [1 ]
Maccabi, Ashkan [1 ]
Singh, Rahul [1 ]
Culjat, Martin [1 ]
Grundfest, Warren [1 ]
Hubschman, Jean-Pierre [2 ]
Brown, Elliott [3 ]
机构
[1] Ctr Adv Surg & Intervent Technol, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Jules Stein Eye Inst, Los Angeles, CA 90095 USA
[3] Wright State Univ, Dept Phys & Elect Engn, Dayton, OH 45435 USA
基金
美国国家科学基金会;
关键词
terahertz imaging; THz reflectometry; corneal health; hydration sensing; DIELECTRIC-PROPERTIES; THZ EXPOSURE; EX-VIVO; THICKNESS;
D O I
10.1117/1.JBO.17.9.097008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Terahertz corneal hydration sensing has shown promise in ophthalmology applications and was recently shown to be capable of detecting water concentration changes of about two parts in a thousand in ex vivo corneal tissues. This technology may be effective in patient monitoring during refractive surgery and for early diagnosis and treatment monitoring in diseases of the cornea. In this work, Fuchs dystrophy, cornea transplant rejection, and keratoconus are discussed, and a hydration sensitivity of about one part in a hundred is predicted to be needed to successfully distinguish between diseased and healthy tissues in these applications. Stratified models of corneal tissue reflectivity are developed and validated using ex vivo spectroscopy of harvested porcine corneas that are hydrated using polyethylene glycol solutions. Simulation of the cornea's depth-dependent hydration profile, from 0.01 to 100 THz, identifies a peak in intrinsic reflectivity contrast for sensing at 100 GHz. A 100 GHz hydration sensing system is evaluated alongside the current standard ultrasound pachymetry technique to measure corneal hydration in vivo in four rabbits. A hydration sensitivity, of three parts per thousand or better, was measured in all four rabbits under study. This work presents the first in vivo demonstration of remote corneal hydration sensing. (C) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI:10.1117/1.JBO.17.9.097008]
引用
收藏
页数:7
相关论文
共 35 条
[1]  
Bauer NJC, 1998, INVEST OPHTH VIS SCI, V39, P831
[2]   Terahertz sensing in corneal tissues [J].
Bennett, David B. ;
Taylor, Zachary D. ;
Tewari, Pria ;
Singh, Rahul S. ;
Culjat, Martin O. ;
Grundfest, Warren S. ;
Sassoon, Daniel J. ;
Johnson, R. Duncan ;
Hubschman, Jean-Pierre ;
Brown, Elliott R. .
JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (05)
[3]   Stratified Media Model for Terahertz Reflectometry of the Skin [J].
Bennett, David B. ;
Li, Wenzao ;
Taylor, Zachary D. ;
Grundfest, Warren S. ;
Brown, Elliott R. .
IEEE SENSORS JOURNAL, 2011, 11 (05) :1253-1262
[4]   Multispectral classification techniques for terahertz pulsed imaging: an example in histopathology [J].
Berry, E ;
Handley, JW ;
Fitzgerald, AJ ;
Merchant, WJ ;
Boyle, RD ;
Zinov'ev, NN ;
Miles, RE ;
Chamberlain, JM ;
Smith, MA .
MEDICAL ENGINEERING & PHYSICS, 2004, 26 (05) :423-430
[5]  
Chatterjee S., 2006, Regression Analysis by Example, V4th, P317
[6]   Effects of THz exposure on human primary keratinocyte differentiation and viability [J].
Clothier, RH ;
Bourne, N .
JOURNAL OF BIOLOGICAL PHYSICS, 2003, 29 (2-3) :179-185
[7]   THz radiation studies on biological systems at the ENEA FEL facility [J].
Doria, A ;
Gallerano, GP ;
Giovenale, E ;
Messina, G ;
Lai, A ;
Ramundo-Orlando, A ;
Sposato, V ;
D'Arienzo, M ;
Perrotta, A ;
Romanò, M ;
Sarti, M ;
Scarfi, MR ;
Spassovsky, I ;
Zeni, O .
INFRARED PHYSICS & TECHNOLOGY, 2004, 45 (5-6) :339-347
[8]   EXCIMER-LASER ABLATION RATE AND CORNEAL HYDRATION [J].
DOUGHERTY, PJ ;
WELLISH, KL ;
MALONEY, RK .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1994, 118 (02) :169-176
[9]   Catalogue of human tissue optical properties at terahertz frequencies [J].
Fitzgerald, AJ ;
Berry, E ;
Zinov'ev, NN ;
Homer-Vanniasinkam, S ;
Miles, RE ;
Chamberlain, JM ;
Smith, MA .
JOURNAL OF BIOLOGICAL PHYSICS, 2003, 29 (2-3) :123-128
[10]  
Freytag G., 1910, Arch Vergl Opthal, V1, P61