The Berkeley Rudimentary Vision Test

被引:72
作者
Bailey, Ian L. [1 ]
Jackson, A. Jonathan [2 ,3 ]
Minto, Hasan [4 ]
Greer, Robert B. [1 ]
Chu, Marlena A. [1 ]
机构
[1] Univ Calif Berkeley, Sch Optometry, Berkeley, CA 94720 USA
[2] Royal Victoria Hosp, Belfast BT12 6BA, Antrim, North Ireland
[3] Australian Coll Optometrists, Melbourne, Vic, Australia
[4] Int Ctr Eyecare Educ, Islamabad, Pakistan
关键词
visual acuity; low vision; severe visual impairment; clinical tests; visual task complexity; VISUAL-ACUITY TEST; COUNTING FINGERS; LETTER CHARTS; HAND MOTION; TRIALS;
D O I
10.1097/OPX.0b013e318264e85a
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. Very poor visual acuity often cannot be measured with letter charts even at close viewing distances. The Berkeley Rudimentary Vision Test (BRVT) was developed as a simple test to extend the range of visual acuity measurement beyond the limits of letter charts by systematically simplifying the visual task and using close viewing distances to achieve large angular sizes. The test has three pairs of hinged cards, 25 cm square. One card-pair has four Single Tumbling E (STE) optotypes at sizes 100 M, 63 M, 40 M, and 25 M. Another card-pair has four Grating Acuity (GA) targets at sizes 200 M, 125 M, 80 M, and 50 M. The third card-pair has a test of White Field Projection (WFP) and a test of Black White Discrimination (BWD). As a demonstration of feasibility, a population of subjects with severe visual impairment was tested with the BRVT. Methods. Adults with severe visual impairments from a wide variety of causes were recruited from three different rehabilitation programs. Vision measurements were made on 54 eyes from 37 subjects; test administration times were measured. Results. For this population, letter chart visual acuity could be measured on 24 eyes. Measurements of visual acuity for STE targets were made for 18 eyes and with GA targets, for two eyes. Five eyes had WFP, and one had BWD. Four had light perception only. The median testing time with the BRVT was 2.5 min. Discussion. The BRVT extends the range of visual acuity up to logMAR = 2.60 (20/8000) for STEs, to logMAR = 2.90 (20/16,000) for gratings and includes the WFP and BWD tests. Conclusions. The BRVT is a simple and efficient test of spatial vision that, with 13 increments, extends the range of measurement from the limits of the letter chart up to light perception. (Optom Vis Sci 2012;89:1257-1264)
引用
收藏
页码:1257 / 1264
页数:8
相关论文
共 50 条
  • [41] HYPERACUITY TEST TO EVALUATE VISION THROUGH DENSE CATARACTS - RESEARCH PRELIMINARY TO A CLINICAL-STUDY IN INDIA
    ENOCH, JM
    GIRALDEZ, MJ
    HUANG, DH
    HIROSE, H
    KNOWLES, R
    NAMPERUMALSAMY, P
    LABREE, L
    AZEN, SP
    OPTICAL ENGINEERING, 1995, 34 (03) : 765 - 771
  • [42] The Measurement of Contrast Sensitivity in Near Vision: The Use of a Digital System vs. a Conventional Printed Test
    Mena-Guevara, Kevin J.
    Pinero, David P.
    Luque, Maria Jose
    de Fez, Dolores
    TECHNOLOGIES, 2024, 12 (07)
  • [43] Monocular visual acuity measured with the OccluPad binocular vision test in patients with unilateral functional visual loss
    Yo Iwata
    Tomoya Handa
    Hitoshi Ishikawa
    Optical Review, 2019, 26 : 301 - 302
  • [44] The Caledonian face test: A new test of face discrimination
    Logan, Andrew J.
    Wilkinson, Frances
    Wilson, Hugh R.
    Gordon, Gael E.
    Loffler, Gunter
    VISION RESEARCH, 2016, 119 : 29 - 41
  • [45] Digital zoom for low vision enhancement systems
    Venkatachalam, R
    Strong, JG
    Wong, W
    Hornsey, RI
    HUMAN VISION AND ELECTRONIC IMAGING IX, 2004, 5292 : 376 - 385
  • [46] Vision in high-level football officials
    Goncalves Baptista, Antonio Manuel
    Serra, Pedro M.
    McAlinden, Colm
    Barrett, Brendan T.
    PLOS ONE, 2017, 12 (11):
  • [47] Simulating Visibility and Reading Performance in Low Vision
    Xiong, Ying-Zi
    Lei, Quan
    Calabrese, Aurelie
    Legge, Gordon E.
    FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [48] Quantification of Functional Vision in Severe Visual Impairment
    Bailey, I. L.
    Jackson, A. J.
    Minto, H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [49] Contrast sensitivity with bifocal intraocular lenses is halved, as measured with the Freiburg Vision Test (FrACT), yet patients are happy
    Alexandra Anton
    Daniel Böhringer
    Michael Bach
    Thomas Reinhard
    Florian Birnbaum
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2014, 252 : 539 - 544
  • [50] A checklist for the evaluation of low vision in non collaborative subjects
    Salati, R
    Aldè, PG
    Cannao, R