A potentiometric biosensor for D-amygdalin based on a consolidated biocomposite membrane

被引:6
|
作者
Merkoçi, A [1 ]
Braga, S [1 ]
Fàbregas, E [1 ]
Alegret, S [1 ]
机构
[1] Autonomous Univ Barcelona, Dept Quim, Grp Sensors & Biosensors, E-08193 Bellaterra, Catalonia, Spain
关键词
D-amygdalin; potentiometric biosensor; consolidated biocomposite; beta-glucosidase;
D O I
10.1016/S0003-2670(99)00201-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new potentiometric biosensor for D-amygdalin based on a consolidated biocomposite membrane has been designed. The manufacturing technique involved a simple compression of dry components presenting an ideal technology for the mass production of potentiometric biosensor devices. The effect of high pressures applied during the preparation of a D-amygdalin biosensor membrane was studied. The immobilisation of beta-glucosidase was improved by increasing this pressure. The optimal biocomposite membrane composition was 100 mg electroactive salts (AgI, Ag2S) and 10 mg enzyme (50 U). Characteristics such as linear range, response times and degree of enzyme immobilisation were studied for each of the pressures used in the production of the membranes. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:65 / 72
页数:8
相关论文
共 50 条
  • [21] Potentiometric cholinesterase biosensor with a membrane modified with calix[4]resorcinolarene
    Evtyugin, GA
    Muslinkina, LA
    Budnikov, GK
    Kazakova, EK
    JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 54 (04) : 367 - 371
  • [22] AMPEROMETRIC BIOSENSOR FOR THE D-SORBITOL BASED ON MODIFIED WITH BIOCOMPOSITE FILM GLASSY CARBON ELECTRODE
    Mazurenko, E. A.
    Shevchenko, O. V.
    Tananaiko, O. Yu.
    Etienne, M.
    Walcarius, A.
    METHODS AND OBJECTS OF CHEMICAL ANALYSIS, 2012, 7 (04): : 176 - 183
  • [23] Porous silicon based potentiometric triglyceride biosensor
    Reddy, RRK
    Chadha, A
    Bhattacharya, E
    BIOSENSORS & BIOELECTRONICS, 2001, 16 (4-5): : 313 - 317
  • [24] The potentiometric biosensor based on polyaniline semiconductor films
    Karyakin, AA
    Bobrova, OA
    Karyakina, EE
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 1996, 32 (08) : 939 - 942
  • [25] A potentiometric polypyrrole-based glucose biosensor
    Trojanowicz, M
    Hitchman, ML
    ELECTROANALYSIS, 1996, 8 (03) : 263 - 266
  • [26] Polypyrrole-based potentiometric phosphate biosensor
    Lawal, A. T.
    Adeloju, S. B.
    JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2010, 63 (1-2) : 45 - 49
  • [27] A Urea Potentiometric Biosensor Based on a Thiophene Copolymer
    Lai, Cheng-Yuan
    Foot, Peter J. S.
    Brown, John W.
    Spearman, Peter
    BIOSENSORS-BASEL, 2017, 7 (01):
  • [28] Organophosphorus pesticide determination with a potentiometric biosensor based on acetyleholinesterase
    Dondoi, MP
    Danet, AF
    Bucur, B
    Cheregi, MC
    REVISTA DE CHIMIE, 2005, 56 (04): : 327 - 330
  • [29] Preliminary investigations on a glucose biosensor based on the potentiometric principle
    Liao, Cheng-Wei
    Chou, Jung-Chuan
    Sun, Tai-Ping
    Hsiung, Shen-Kan
    Hsieh, Jui-Hsiang
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (02): : 720 - 726
  • [30] Porous silicon-based potentiometric biosensor for triglycerides
    Setzu, S.
    Salis, S.
    Demontis, V.
    Salis, A.
    Monduzzi, M.
    Mula, Guido
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2007, 204 (05): : 1434 - 1438