Reduction of matrix effects in quantitative and semi-quantitative inductively coupled plasma-optical emission spectrometry using a partial local thermodynamic equilibrium model and an internal standard

被引:11
作者
Dettman, Joshua R. [1 ,2 ]
Olesik, John W. [1 ]
机构
[1] Ohio State Univ, Sch Earth Sci, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Chem, Columbus, OH 43210 USA
关键词
ICP-OES; Matrix effect; Plasma temperature; LINE INTENSITY RATIOS; DEVICE DETECTOR; AEROSOL TRANSPORT; ELECTRON-DENSITY; NUMBER DENSITIES; TRACE-ELEMENTS; SPRAY CHAMBER; SAMPLE MATRIX; ARGON PLASMA; ICP-OES;
D O I
10.1016/j.sab.2012.06.047
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A means to reduce matrix effects by using a simple pLTE model to account for changes in sensitivity due to matrix induced changes in plasma temperature and an internal standard to account for matrix induced changes in sample transport rate is described. For quantitative analysis where standards contain all of the elements of interest the changes in sensitivity due to 1.0 M Ba and Na and 1.5 M Li and Ca are reduced to less than 20% for most analyte lines investigated using this method. The maximum error due to the presence of 1.5 M La is reduced from more than a factor of 14 to less than 40%. Semi-quantitative concentrations from the pLTE model based single element calibration approach described previously are essentially independent of matrix composition (within the uncertainty of semi-quantitative concentrations in the absence of a high matrix concentration) for the concomitant elements tested. However, the pLTE based approach is less accurate for semi-quantitative analysis than a one-time multi-element calibration, except when the most severe matrix effects are observed (such as those due to 1.5 M La). (C) 2012 Elsevier By. All rights reserved.
引用
收藏
页码:96 / 108
页数:13
相关论文
共 81 条
[1]   SPECTROMETRIC STUDY OF HIGH-FREQUENCY INDUCED PLASMA .2. DIFFERENT TYPES OF INTERFERENCES OBSERVED [J].
ABDALLAH, MH ;
MERMET, JM ;
TRASSY, C .
ANALYTICA CHIMICA ACTA, 1976, 87 (02) :329-339
[2]   Correction for non-spectroscopic matrix effects in inductively coupled plasma-atomic emission spectroscopy by internal standardization using spectral lines of the same analyte [J].
Al-Ammar, AS ;
Barnes, RM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (11) :1583-1593
[3]   ELIMINATION OF INTERFERENCES AND EFFECTS FROM DRIFT IN WORKING PARAMETERS IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY BY USING A COMBINATION OF THE GENERALIZED STANDARD ADDITION METHOD AND THE GENERALIZED INTERNAL REFERENCE METHOD [J].
ALAMMAR, AS ;
HAMID, HA ;
RASHID, BH .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (4-5) :359-366
[4]   AN EXPERIMENTAL STUDY OF INTERNAL STANDARDIZATION IN ANALYTICAL EMISSION SPECTROSCOPY [J].
BARNETT, WB ;
KNISELEY, RN .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1970, B 25 (03) :139-&
[5]   THEORETICAL PRINCIPLES OF INTERNAL STANDARDIZATION IN ANALYTICAL EMISSION SPECTROSCOPY [J].
BARNETT, WB ;
FASSEL, VA ;
KNISELEY, RN .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1968, B 23 (10) :643-&
[6]  
Bates L. C., 1991, THESIS U N CAROLINA
[7]   INTERFERENCE FROM EASILY IONIZABLE ELEMENT MATRICES IN INDUCTIVELY COUPLED PLASMA EMISSION-SPECTROMETRY - A SPATIAL STUDY [J].
BLADES, MW ;
HORLICK, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1981, 36 (09) :881-900
[8]   STUDIES OF A RADIO-FREQUENCY INDUCTIVELY COUPLED ARGON PLASMA FOR OPTICAL EMISSION SPECTROMETRY .3. INTERFERENCE EFFECTS UNDER COMPROMISE CONDITIONS FOR SIMULTANEOUS MULTI-ELEMENT ANALYSIS [J].
BOUMANS, PWJM ;
DEBOER, FJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1976, 31 (06) :355-375
[9]   Compensation of Ca and Na interference effects in axially and radially viewed inductively coupled plasmas [J].
Brenner, IB ;
Le Marchand, A ;
Daraed, C ;
Chauvet, L .
MICROCHEMICAL JOURNAL, 1999, 63 (03) :344-355
[10]   Axially and radially viewed inductively coupled plasmas - a critical review [J].
Brenner, IB ;
Zander, AT .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (08) :1195-1240