Effects of image positions on temperature reconstruction using light field camera

被引:2
|
作者
Li, Tianjiao [1 ,2 ]
Zhang, Chuanxin [1 ]
Yuan, Yuan [1 ,2 ]
Shuai, Yong [1 ,2 ]
Tan, Heping [1 ,2 ]
机构
[1] Harbin Inst Technol, Key Lab Aerosp Thermophys, Minist Ind & Informat Technol, 92 West Dazhi St, Harbin 150001, Peoples R China
[2] Harbin Inst Technol, Sch Energy & Sci Engn, 92 West Dazhi St, Harbin 150001, Peoples R China
基金
中国国家自然科学基金;
关键词
Radiative transfer; Light field camera; Temperature reconstruction; VOLUME FRACTION FIELDS; FLAME TEMPERATURE; 3-DIMENSIONAL TEMPERATURE; RADIATIVE PROPERTIES; ABSORPTION-COEFFICIENT; COMBUSTION; TOMOGRAPHY; ARRAY; SOOT; H2O;
D O I
10.1016/j.rinp.2020.103146
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The light field camera has emerged as an optical flame temperature detection device owing to the refocusing feature. Combining this feature with the deconvolution algorithm, a three-dimensional flame temperature distribution can be reconstructed. However, the accuracy of reconstructing the flame temperature is limited by the actual image position. Based on the established flame and light field camera model, the proposed Lucy-Richardson and Nearest Neighbor Filtering joint deconvolution algorithm is applied to sectioned temperature reconstruction. Thus, the effects of image position using light field camera on temperature reconstruction are verified. The relative error of flame temperature reconstruction is less than 10%, if the flame is imaged in the middle of the light field image. However, if the flame is imaged at the image edge, the edge distortion and defocused state of the camera increase the relative error to less than 11% and 14%, respectively. The effects of image positions are not too significant for temperature reconstruction using light field camera.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] 3D Image Reconstruction of Sclera Using A Light Field Camera
    Heriana, Octa
    Suksmono, Andriyan Bayu
    Zakaria, Hasballah
    Prahasta, Andika
    13TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2021), 2018,
  • [2] Meshed axisymmetric flame simulation and temperature reconstruction using light field camera
    Li, Tianjia
    Gao, Peng
    Zhang, Chuanxin
    Yuan, Yuan
    Liu, Dong
    Shuai, Yong
    Tan, Heping
    OPTICS AND LASERS IN ENGINEERING, 2022, 158
  • [3] Control camera and light source positions using image gradient information
    Marchand, Eric
    PROCEEDINGS OF THE 2007 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-10, 2007, : 417 - 422
  • [4] Three dimensional reconstruction using a lenslet light field camera
    Zhang, Wentao
    Chang, Shengqian
    Tao, Xiao
    Wang, Chang
    Tao, Chenning
    Huang, Peizheng
    Zheng, Zhenrong
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XLI, 2018, 10752
  • [5] Image Formation Analysis and Light Field Information Reconstruction for Plenoptic Camera 2.0
    Liu, Li
    Jin, Xin
    Dai, Qionghai
    ADVANCES IN MULTIMEDIA INFORMATION PROCESSING - PCM 2017, PT I, 2018, 10735 : 609 - 618
  • [6] Turbulence image correction using focused light field camera
    Wang, Yan
    Sun, Quan
    Han, Kai
    AIP ADVANCES, 2024, 14 (06)
  • [7] Underwater Image Dehazing with a Light Field Camera
    Skinner, Katherine A.
    Johnson-Roberson, Matthew
    2017 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS (CVPRW), 2017, : 1775 - 1782
  • [8] Model-independent light field reconstruction using a generic camera calibration
    Uhlig, David
    Heizmann, Michael
    TM-TECHNISCHES MESSEN, 2021, 88 (06) : 361 - 373
  • [9] Modeling the calibration pipeline of the Lytro camera for high quality light-field image reconstruction
    Cho, Donghyeon
    Lee, Minhaeng
    Kim, Sunyeong
    Tai, Yu-Wing
    2013 IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV), 2013, : 3280 - 3287
  • [10] Optical Sectioning Tomographic Reconstruction of Three-Dimensional Flame Temperature Distribution Using Single Light Field Camera
    Zhao, Wenchao
    Zhang, Biao
    Xu, Chuanlong
    Duan, Lunbo
    Wang, Shimin
    IEEE SENSORS JOURNAL, 2018, 18 (02) : 528 - 539