Reducing task-based fMRI scanning time using simultaneous multislice echo planar imaging

被引:9
|
作者
Kiss, Mate [1 ,2 ,3 ]
Hermann, Petra [1 ]
Vidnyanszky, Zoltan [1 ]
Gal, Viktor [1 ]
机构
[1] Hungarian Acad Sci, Res Ctr Nat Sci, Brain Imaging Ctr, Magyar Tudosok Korutja 2, H-1117 Budapest, Hungary
[2] MR Res Ctr, Janos Szentagothai PhD Sch, Balassa St 6, H-1083 Budapest, Hungary
[3] Natl Inst Clin Neurosci, Dept Neuroradiol, Amerikai St 57, H-1145 Budapest, Hungary
关键词
Presurgical functional MRI; Simultaneous multislice technique; fMRI efficiency; Eloquent areas; Thresholding; Surgical planning; BRAIN-TUMOR; IMPACT; RESOLUTION; AREA; EPI; MRI;
D O I
10.1007/s00234-017-1962-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
To maintain alertness and to remain motionless during scanning represent a substantial challenge for patients/subjects involved in both clinical and research functional magnetic resonance imaging (fMRI) examinations. Therefore, availability and application of new data acquisition protocols allowing the shortening of scan time without compromising the data quality and statistical power are of major importance. Higher order category-selective visual cortical areas were identified individually, and rapid event-related fMRI design was used to compare three different sampling rates (TR = 2000, 1000, and 410 ms, using state-of-the-art simultaneous multislice imaging) and four different scanning lengths to match the statistical power of the traditional scanning methods to high sampling-rate design. The results revealed that similar to 4 min of the scan time with 1 Hz (TR = 1000 ms) sampling rate and similar to 2 min scanning at similar to 2.5 Hz (TR = 410 ms) sampling rate provide similar localization sensitivity and selectivity to that obtained with 11-min session at conventional, 0.5 Hz (TR = 2000 ms) sampling rate. Our findings suggest that task-based fMRI examination of clinical population prone to distress such as presurgical mapping experiments might substantially benefit from the reduced (20-40%) scanning time that can be achieved by the application of simultaneous multislice sequences.
引用
收藏
页码:293 / 302
页数:10
相关论文
共 50 条
  • [21] Effect of Task-Correlated Physiological Fluctuations and Motion in 2D and 3D Echo-Planar Imaging in a Higher Cognitive Level fMRI Paradigm
    Ladstein, Jarle
    Evensmoen, Hallvard R.
    Haberg, Asta K.
    Kristoffersen, Anders
    Goa, Pal E.
    FRONTIERS IN NEUROSCIENCE, 2016, 10
  • [22] Improving the Sensitivity of Task-Based Multi-Echo Functional Magnetic Resonance Imaging via T2* Mapping Using Synthetic Data-Driven Deep Learning
    Zhao, Yinghe
    Yang, Qinqin
    Qian, Shiting
    Dong, Jiyang
    Cai, Shuhui
    Chen, Zhong
    Cai, Congbo
    BRAIN SCIENCES, 2024, 14 (08)
  • [23] Image quality and whole-lesion histogram and texture analysis of diffusion-weighted imaging of breast MRI based on advanced ZOOMit and simultaneous multislice readout-segmented echo-planar imaging
    Sun, Kun
    Zhu, Hong
    Xia, Bingqing
    Li, Xinyue
    Chai, Weimin
    Fu, Caixia
    Thomas, Benkert
    Liu, Wei
    Grimm, Robert
    Elisabeth, Weiland
    Yan, Fuhua
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [24] Diffusion tensor imaging focusing on lower cervical spinal cord using 2D reduced FOV interleaved multislice single-shot diffusion-weighted echo-planar imaging: comparison with conventional single-shot diffusion-weighted echo-planar imaging
    Park, Eun Hae
    Lee, Young Han
    Jeong, Eun-Kee
    Roh, Yun Ho
    Suh, Jin-Suck
    MAGNETIC RESONANCE IMAGING, 2015, 33 (04) : 401 - 406
  • [25] Distortion-Free Diffusion Imaging Using Self-Navigated Cartesian Echo-Planar Time Resolved Acquisition and Joint Magnitude and Phase Constrained Reconstruction
    Dai, Erpeng
    Lee, Philip K.
    Dong, Zijing
    Fu, Fanrui
    Setsompop, Kawin
    McNab, Jennifer A.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (01) : 63 - 74
  • [26] Improvement of Temporal Signal-to-Noise Ratio of GRAPPA Accelerated Echo Planar Imaging Using a FLASH Based Calibration Scan
    Talagala, S. Lalith
    Sarlls, Joelle E.
    Liu, Siyuan
    Inati, Souheil J.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (06) : 2362 - 2371
  • [27] Multiband accelerated spin-echo echo planar imaging with reduced peak RF power using time-shifted RF pulses
    Auerbach, Edward J.
    Xu, Junqian
    Yacoub, Essa
    Moeller, Steen
    Ugurbil, Kamil
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (05) : 1261 - 1267
  • [28] High Temporal Resolution Motion Estimation Using a Self-Navigated Simultaneous Multi-Slice Echo Planar Imaging Acquisition
    Teruel, Jose R.
    Kuperman, Joshua M.
    Dale, Anders M.
    White, Nathan S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 48 (03) : 780 - 787
  • [29] An exploration of task based fMRI in neonates using echo-shifting to allow acquisition at longer TE without loss of temporal efficiency
    Ferrazzi, Giulio
    Nunes, Rita G.
    Arichi, Tomoki
    Gaspar, Andreia S.
    Barone, Giovanni
    Allievi, Alessandro
    Vasylechko, Serge
    Abaei, Maryam
    Hughes, Emer
    Rueckert, Daniel
    Price, Anthony N.
    Hajnal, Joseph V.
    NEUROIMAGE, 2016, 127 : 298 - 306
  • [30] Improved Readout-Segmented Echo-Planner Diffusion-Weighted Magnetic Resonance Imaging of Nasopharyngeal Carcinoma Using Simultaneous Multislice Acquisitions at 3 T
    Li, Qiao
    Jiang, TingTing
    Wang, TingTing
    Huang, Yan
    Hu, XiaoXin
    Zhang, Ling
    Liu, Wei
    Fu, CaiXia
    Gu, YaJia
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (05) : 815 - 822