Reproducibility of near-infrared spectroscopy parameters measured during brachial artery occlusion and reactive hyperemia in healthy men

被引:43
|
作者
Lacroix, Sebastien [1 ,2 ,3 ]
Gayda, Mathieu [1 ,2 ,3 ]
Gremeaux, Vincent [2 ,3 ,4 ,5 ]
Juneau, Martin [1 ,2 ,3 ]
Tardif, Jean-Claude [1 ,3 ]
Nigam, Anil [1 ,2 ,3 ]
机构
[1] Montreal Heart Inst, Res Ctr, Montreal, PQ H1T 1C8, Canada
[2] Montreal Heart Inst Montreal, Cardiovasc Rehabil & Prevent Ctr EPIC, Quebec City, PQ, Canada
[3] Univ Montreal, Fac Med, Montreal, PQ H3C 3J7, Canada
[4] Inserm U1093, Dijon, France
[5] CHU Dijon, Inserm CIC P 803, Dijon, France
关键词
reproducibility; near-infrared spectroscopy; reactive hyperemia; cardiometabolic risk; microvascular function; CHRONIC HEART-FAILURE; SKELETAL-MUSCLE; PERIPHERAL MICROCIRCULATION; INSULIN-RESISTANCE; SPORTS-MEDICINE; EXERCISE; RELIABILITY; CONSUMPTION; FLOW;
D O I
10.1117/1.JBO.17.7.077010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Near-infrared spectroscopy (NIRS) is a noninvasive technique evaluating microvascular function. The aim of this study was to assess the reproducibility of NIRS parameters during reactive hyperemia induced by a 5 min brachial artery occlusion. Twenty-four healthy young males (mean 34 +/- 8 years old) had two microvascular function evaluations by NIRS over a 7 to 30-day period (mean 16 +/- 10 days). Intra-subject and inter-observer reproducibility were evaluated with intraclass correlation coefficient (ICC), coefficient of variation (CV), and standard error of measurement (SEM%) for every parameter. Mean NIRS parameters did not differ between both evaluations. Reproducibility was greatest for muscle oxygen consumption (ICC: 0.84; CV: 6.51%; SEM: 7.11%), time to basal O(2)Hb (ICC: 0.63, CV: 20.04%, SEM 27.22%), time to maximal O(2)Hb (ICC: 0.71; CV: 15.61%; SEM: 19.27%), peak of O(2)Hb (ICC: 0.63, CV: 6.68%, SEM 8.53%), time to maximal tHb (ICC: 0.73, CV: 19,61%, SEM 24.56%) and area under the O(2)Hb and tHb curves (ICC: 0.68, CV: 16.15%, SEM 22.93% and ICC: 0.62, CV: 18.59%, SEM 26.64%, respectively). Moreover, inter-observer reproducibility ranged from excellent to perfect (ICC from 0.85 to 1.00) for every parameter. NIRS parameters during reactive hyperemia are highly reproducible which enables their repeated measurement to study microvascular function in healthy subjects. (C) 2012 society of Photo-ptical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.JBO.17.7.077010]
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Microvascular responses during reactive hyperemia assessed by near-infrared spectroscopy and arterial stiffness in young, middle-aged, and older women
    Horiuchi, Masahiro
    Okita, Koichi
    MICROVASCULAR RESEARCH, 2020, 129
  • [22] Evaluation of collateral network near-infrared spectroscopy during and after segmental artery occlusion in a chronic large animal model
    von Aspern, Konstantin
    Haunschild, Josephina
    Ziemann, Martin
    Misfeld, Martin
    Mohr, Friedrich W.
    Borger, Michael A.
    Etz, Christian D.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 158 (01) : 155 - +
  • [23] Use of near-infrared spectroscopy to monitor cerebral oxygenation during coronary artery bypass surgery in a patient with bilateral internal carotid artery occlusion
    Blas, M
    Sulek, C
    Martin, T
    Lobato, E
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1999, 13 (06) : 732 - 735
  • [24] Cerebral oxygenation measured by near-infrared spectroscopy during circulatory arrest and cardiopulmonary resuscitation
    Nagdyman, N
    Fleck, TPK
    Ewert, P
    Abdul-Khaliq, H
    Redlin, M
    Lange, PE
    BRITISH JOURNAL OF ANAESTHESIA, 2003, 91 (03) : 438 - 442
  • [25] Near-infrared spectroscopy during cesarean section with common iliac artery balloon occlusion for total placenta previa: a case report
    Okada, A.
    Tanaka, K.
    Kajitani, K.
    Nishimoto, S.
    Nakamura, H.
    Nakamoto, O.
    CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 2018, 45 (01) : 112 - 114
  • [26] Hemodynamic variations measured with near-infrared spectroscopy in human forearm muscles in response to venous occlusion: An electrical model
    Van Toi, V
    Hoimes, ML
    Nadgir, S
    Fantini, S
    Optical Tomography and Spectroscopy of Tissue VI, 2005, 5693 : 495 - 502
  • [27] Understanding metabolic responses to forearm arterial occlusion measured with two-channel broadband near-infrared spectroscopy
    Saeed, Fiza
    Carter, Caroline
    Kolade, John
    Brothers, Robert Matthew
    Liu, Hanli
    JOURNAL OF BIOMEDICAL OPTICS, 2024, 29 (11)
  • [28] Near-Infrared Spectroscopy Does Not Track Forearm Blood Flow during Venous Occlusion Plethysmography
    Perlet, Michael R.
    Herren, Jeremy T.
    Traylor, Miranda K.
    Bailey, Matthew D.
    Keller, Joshua L.
    APPLIED SCIENCES-BASEL, 2024, 14 (08):
  • [29] Brain Activity Measured With Near-Infrared Spectroscopy During EMDR Treatment of Phantom Limb Pain
    Amano, Tamaki
    Seiyama, Akitoshi
    Toichi, Motomi
    JOURNAL OF EMDR PRACTICE AND RESEARCH, 2013, 7 (03) : 144 - 153
  • [30] CHANGES IN SKELETAL-MUSCLE OXYGENATION DURING INCREMENTAL EXERCISE MEASURED WITH NEAR-INFRARED SPECTROSCOPY
    BELARDINELLI, R
    BARSTOW, TJ
    PORSZASZ, J
    WASSERMAN, K
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1995, 70 (06): : 487 - 492