WEAR OF MATRIX OVERDENTURE ATTACHMENTS AFTER ONE TO EIGHT YEARS OF CLINICAL USE

被引:6
|
作者
Fromentin, Olivier [2 ,3 ]
Lassauzay, Claire [4 ,5 ]
Nader, Samer Abi [1 ]
Feine, Jocelyne
de Albuquerque, Rubens F., Jr. [1 ,6 ]
机构
[1] McGill Univ, Fac Dent, Dept Prosthodont, Montreal, PQ, Canada
[2] Univ Paris 07, Fac Odontol, Dept Prosthodont, UFR Odontol, Paris, France
[3] Rothschild Hosp, Paris, France
[4] Clermont 1 Univ, Fac Odontol, Dept Prosthodont, UFR Odontol, Clermont Ferrand, France
[5] Clermont Ferrand Univ Hosp Ctr, Paris, France
[6] Univ Sao Paulo, Fac Odontol, Fac Dent Ribeirao Preto, BR-14049 Ribeirao Preto, Brazil
关键词
IMPLANT-SUPPORTED OVERDENTURES; MANDIBULAR OVERDENTURES; PROSTHETIC COMPLICATIONS; BALL ATTACHMENTS; PROSTHODONTIC MAINTENANCE; RETAINED OVERDENTURES; BAR ATTACHMENTS; SYSTEMS; RETENTION; TRIAL;
D O I
10.1016/S0022-3913(12)60055-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Matrices of unsplinted attachment systems are generally reported to be the weak component of implant overdentures, often requiring frequent maintenance. Clinical wear results in reduced retention of the prosthesis, requiring activation or renewal of the matrix to restore the initial level of retention. Purpose. The purpose of this retrospective study was to measure the wear of the matrix of a ball attachment after various periods of clinical wear. Material and methods. Seventy specimens of 3 groups of matrices of ball attachments that had been in use for mean periods of 12.3 months (1Y group, n=26), 39.0 months (3Y group, n=28) and 95.6 months (8Y group, n=16) were retrieved from 35 patients (2 specimens per patient) and measured on a coordinate measuring machine equipped with a touch trigger probe. Ten unused matrices were used as controls (CTRL group). The external and internal matrix diameters and deviations from circularity were measured. For the various time periods, the decreases in matrix thickness were calculated and compared with controls. Kruskal-Wallis 1-way ANOVA by ranks, followed by the Mann-Whitney post hoc tests, were conducted to test for differences in median values among groups (alpha=.05). Results. For the internal upper diameter of the matrices tested, the Kruskal-Wallis and Mann-Whitney tests revealed significant differences for the 3 groups compared to the controls. For group 1Y, a significant difference (P<.001) of the internal upper diameter was found compared to the CTRL group. Compared to the controls, the nonparametric analyses for groups 3Y and 8Y showed significant differences for the internal upper diameter (P<.001) and deviations from circularity (P<.001). For groups 1Y, 3Y and 8Y, matrix thickness losses were 07, 47 and 70 pm, respectively. Conclusions. Within the limitations of this study, it was observed that one year of clinical wear had limited effect on the ball attachment matrices. Three to 8 years of clinical use resulted in a significant decrease of matrix thickness, especially at the tip of the retentive lamellae. (J Prosthet Dent 2012;107:191-198)
引用
收藏
页码:191 / 198
页数:8
相关论文
共 9 条
  • [1] Clinical wear of overdenture ball attachments after 1, 3 and 8 years
    Fromentin, Olivier
    Lassauzay, Claire
    Nader, Samer Abi
    Feine, Jocelyne
    de Albuquerque, Rubens F., Jr.
    CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (11) : 1270 - 1274
  • [2] Wear of Ball Attachments After 1 to 8 Years of Clinical Use: A Qualitative Analysis
    Fromentin, Olivier
    Lassauzay, Claire
    Nader, Samer Abi
    Feine, Jocelyne
    de Albuquerque Junior, Rubens F.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2011, 24 (03) : 270 - 272
  • [3] WEAR OF CERAMIC AND TITANIUM BALL ATTACHMENTS IN SUBJECTS WITH AN IMPLANT-RETAINED OVERDENTURE: A CONTROLLED CLINICAL TRIAL
    Buettel, Adrian E.
    Luethy, Heinz
    Sendi, Pedram
    Marinello, Carlo P.
    JOURNAL OF PROSTHETIC DENTISTRY, 2012, 107 (02) : 109 - 113
  • [4] Evaluation of retention and wear of a titanium-formed stud overdenture attachment with different interimplant angulations after simulated clinical use: An in vitro study
    Elsonbaty, Moustafa A.
    Alshimy, Ahmed M.
    Abdul-Monem, Mohamed M.
    Neena, Akram F.
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (02) : 205.e1 - 205.e10
  • [5] Maxillary implant overdenture retained by four unsplinted attachments and opposed by a natural or fixed dentition: One-year clinical outcomes
    Bouhy, Alice
    Rompen, Eric
    Lamy, Marc
    Legros, Caroline
    Lecloux, Geoffrey
    Lambert, France
    CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (08) : 747 - 767
  • [6] Soil Properties after Eight Years of the Use of Strip-Till One-Pass Technology
    Jaskulska, Iwona
    Romaneckas, Kestutis
    Jaskulski, Dariusz
    Galezewski, Lech
    Breza-Boruta, Barbara
    Debska, Bozena
    Lemanowicz, Joanna
    AGRONOMY-BASEL, 2020, 10 (10):
  • [7] Small bowel capsule endoscopy: where do we stand after 20 years of clinical use?
    Pennazio, Marco
    Rondonotti, Emanuele
    Pellicano, Rinaldo
    Cortegoso Valdivia, Pablo
    MINERVA GASTROENTEROLOGY, 2021, 67 (01): : 101 - 108
  • [8] Clinical Performance of One-Piece, Screw-Retained Implant Crowns Based on Hand-Veneered CAD/CAM Zirconia Abutments After a Mean Follow-up Period of 2.3 Years
    Schnider, Nicole
    Forrer, Fiona Alena
    Braegger, Urs
    Hicklin, Stefan Paul
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (01) : 188 - 196
  • [9] Long-term outcome of patients with clinical stage I high-risk nonseminomatous germ-cell tumors 15 years after one adjuvant cycle of bleomycin, etoposide, and cisplatin chemotherapy
    Vidal, A. D.
    Thalmann, G. N.
    Karamitopoulou-Diamantis, E.
    Fey, M. F.
    Studer, U. E.
    ANNALS OF ONCOLOGY, 2015, 26 (02) : 374 - 377