Analysis of steroids in human urine by on line liquid chromatography-gas chromatography-mass spectrometry using the Through Oven Transfer Adsorption Desorption interface and a fraction collector

被引:9
|
作者
Toledano, Rosa M. [1 ]
Diaz-Plaza, Eva M. [2 ]
Cortes, Jose M. [1 ]
Blazquez, Inmaculada [2 ]
Vazquez, Ana [1 ]
Villen, Jesus [1 ]
Munoz-Guerra, Jesus [2 ]
机构
[1] Univ Castilla La Mancha, LC GC Res Grp, Albacete 02071, Spain
[2] Agencia Estatal Antidopaje Espana, Lab Control Dopaje, Madrid 28040, Spain
关键词
On line coupled liquid chromatography-gas chromatography-mass spectrometry; Through Oven Transfer Adsorption; Desorption interface with fraction collector; Steroid analysis; Doping; Human urine; Natural steroids; PHASE LC-GC; ISOTOPE RATIO; SAMPLE PREPARATION; ANABOLIC-STEROIDS; RESIDUE ANALYSIS; DOPING ANALYSIS; TESTOSTERONE; PESTICIDES; INJECTION; DETECT;
D O I
10.1016/j.aca.2012.06.050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Anti-doping laboratories accredited by the WADA (World Anti-Doping Agency) must have available methods capable of detecting synthetic steroids at concentrations below 10 ng mL(-1) and, at the same time, be able to quantify endogenous steroids with accuracy. The unequivocal identification of the steroids must be carried out by GC-MS. In this manuscript we describe a new method by on-line coupled liquid chromatography-gas chromatography (LC-GC) using the Through Oven Transfer Adsorption Desorption (TOTAD) interface and mass spectrometer (MS) detector. By this means, all the analyte eluted in the LC stage are automatically transferred to the GC, avoiding the contamination associated with manipulation of the sample. A newly designed fraction collector is described for the first time. The collector permits the different fractions eluted in LC to be stored and sent individually to the GC by means of the TOTAD interface. The detection limits attained, measured in gas chromatography-mass spectrometry (GC-MS) in SCAN mode, vary between 0.5 and 3.4 ng mL(-1), and the method, once the sample is derivatized, is completely automatic. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:78 / 85
页数:8
相关论文
共 50 条
  • [41] Analysis of chlormequat in human urine as a biomarker of exposure using liquid chromatography triple quadrupole mass spectrometry
    Lindh, Christian H.
    Littorin, Margareta
    Johannesson, Gunvor
    Jonsson, Bo A. G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (19): : 1551 - 1556
  • [42] Quantitative analysis of Δ9-THC-COOH in Human Urine by the Liquid-Liquid Extraction technique and Gas Chromatography-Mass Spectrometry: Adaptation, Optimization and Validation
    de Oliveira, Kleber Ota
    Palma Scanferla, Deborah Thais
    Pereira da Silva, Jordana Quaglia
    Oliveira Madia, Mariana Aparecida
    Bando, Erika
    Machinski Junior, Miguel
    Marchioni, Camila
    Galerani Mossini, Simone Aparecida
    BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 9 (34): : 229 - 239
  • [43] Some aspects of the analysis of environmental pollutants in sediments using pressurized liquid extraction and gas chromatography-mass spectrometry
    Dabrowski, L
    Giergielewicz-Mozajska, H
    Biziuk, M
    Gaca, J
    Nameisnik, J
    JOURNAL OF CHROMATOGRAPHY A, 2002, 957 (01) : 59 - 67
  • [44] Determination of anabolic androgenic steroids as imidazole carbamate derivatives in human urine using liquid chromatography-tandem mass spectrometry
    Fragkaki, Argyro G.
    Petropoulou, Georgia
    Athanasiadou, Ioanna
    Kiousi, Polyxeni
    Kioukia-Fougia, Nassia
    Archontaki, Helen
    Bakeas, Evangelos
    Angelis, Yiannis S.
    JOURNAL OF SEPARATION SCIENCE, 2020, 43 (11) : 2154 - 2161
  • [45] Dilute-and-shoot-liquid chromatography-mass spectrometry for urine analysis in doping control and analytical toxicology
    Deventer, K.
    Pozo, O. J.
    Verstraete, A. G.
    Van Eenoo, P.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 55 : 1 - 13
  • [46] Identification and quantification of the osmodiuretic mannitol in urine for sports drug testing using gas chromatography-mass spectrometry
    Guddat, Sven
    Thevis, Mario
    Schaenzer, Wilhelm
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2008, 14 (03) : 127 - 133
  • [47] Coupling of gas chromatography and electrospray ionization high resolution mass spectrometry for the analysis of anabolic steroids as trimethylsilyl derivatives in human urine
    Cha, Eunju
    Jeong, Eun Sook
    Cha, Sangwon
    Lee, Jaeick
    ANALYTICA CHIMICA ACTA, 2017, 964 : 123 - 133
  • [48] Determination of the Structures of Free and Glucuronidated Metabolites of -Pyrrolidinovalerophenone in Human Urine by Liquid Chromatography-Mass Spectrometry with Accurate Mass Measurement
    Zaikina, O. L.
    Shilov, V. V.
    Lodyagin, A. N.
    Glushkov, S. I.
    Grigoryev, A. M.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 74 (05) : 489 - 504
  • [49] Determination of Levetiracetam in Human Plasma by Dispersive Liquid-Liquid Microextraction Followed by Gas Chromatography-Mass Spectrometry
    Steinhorst Alcantara, Greyce Kelly
    Calixto, Leandro Augusto
    Beraldo de Moraes, Luiz Alberto
    Costa Queiroz, Regina Helena
    Moraes de Oliveira, Anderson Rodrigo
    de Gaitani, Cristiane Masetto
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2016, 2016
  • [50] Dispersive liquid-liquid microextraction using a low transition temperature mixture and liquid chromatography-mass spectrometry analysis of pesticides in urine samples
    Gallo, Valeria
    Tomai, Pierpaolo
    Gherardi, Monica
    Fanali, Chiara
    De Gara, Laura
    D'Orazio, Giovanni
    Gentili, Alessandra
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1642