Gait analysis comparison of cruciate retaining and substituting TKA following PCL sacrifice

被引:31
作者
Joglekar, Siddharth [2 ]
Gioe, Terence J. [1 ]
Yoon, Patrick [1 ]
Schwartz, Michael H. [3 ]
机构
[1] Univ Minnesota, Sch Med, Dept Orthopaed Surg, Minneapolis, MN 55455 USA
[2] Mayo Clin, Dept Orthopaed Surg, Rochester, MN 55905 USA
[3] Univ Minnesota, Sch Med, Gillette Childrens Specialty Healthcare, Ctr Gait & Mot Anal, Minneapolis, MN 55455 USA
关键词
PCL; Posterior cruciate ligament; Total knee arthroplasty; TKA; Knee instability; Gait analysis; TOTAL KNEE ARTHROPLASTY; STAIR ASCENT; POLYETHYLENE INSERT; FUNCTIONAL-ANALYSIS; DYNAMIC STABILITY; LIGAMENT; REPLACEMENT; DESCENT; WALKING; INSTABILITY;
D O I
10.1016/j.knee.2011.05.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The role of the posterior cruciate ligament (PCL) remains controversial in total knee arthroplasty (TKA), with some surgeons who believe in PCL sacrifice and substitution and others who believe in PCL preservation for stability. Manufacturers have developed both cruciate-substituting/posterior stabilized (PS) implants typically used when the ligament is sacrificed and cruciate retaining (CR) implants designed for ligament preservation. However, studies demonstrate excellent clinical results with CR implants despite PCL sacrifice. This study sought to determine functional stability differences between PS and CR TKAs following PCL sacrifice. Eighteen (9 matched pairs) subjects with either a PS or CR TKA and sacrificed PCL and a normal contralateral knee were subjected to physical exam and gait analysis (walking, stair ascent and descent) using a staircase model, passive reflective arrays and an optoelectric system. No differences were detected between the two groups among any of the measured parameters (knee flexion angle, knee flexion moment, knee power absorption, pelvic tilt). PCL sacrifice in a well-balanced cruciate retaining TKA did not result in instability during stair descent based on gait parameters. The decision to use a posterior stabilized design when faced with an incompetent PCL intraoperatively should be based on factors other than anticipated instability. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:279 / 285
页数:7
相关论文
共 53 条
[1]  
Andriacchi T P, 1988, J Arthroplasty, V3 Suppl, pS13, DOI 10.1016/S0883-5403(88)80003-2
[2]   THE INFLUENCE OF TOTAL KNEE-REPLACEMENT DESIGN ON WALKING AND STAIR-CLIMBING [J].
ANDRIACCHI, TP ;
GALANTE, JO ;
FERMIER, RW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (09) :1328-1335
[3]   The use of functional analysis in evaluating knee kinematics [J].
Andriacchi, TP ;
Dyrby, CO ;
Johnson, TS .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :44-53
[4]   FUNCTIONAL-ANALYSIS OF PRE-KNEE AND POST-KNEE SURGERY - TOTAL KNEE ARTHROPLASTY AND ACL RECONSTRUCTION [J].
ANDRIACCHI, TP .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :575-581
[5]   In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties [J].
Banks, SA ;
Markovich, GD ;
Hodge, WA .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :297-304
[6]  
BECKER MW, 1991, CLIN ORTHOP RELAT R, V271, P122
[7]   A comparison of isokinetic strength testing and gait analysis in patients with posterior cruciate-retaining and substituting knee arthroplasties [J].
Bolanos, AA ;
Colizza, WA ;
McCann, PD ;
Gotlin, RS ;
Wootten, ME ;
Kahn, BA ;
Insall, JN .
JOURNAL OF ARTHROPLASTY, 1998, 13 (08) :906-915
[8]   Knee Range of Motion During the First Two Years After Use of Posterior Cruciate-Stabilizing or Posterior Cruciate-Retaining Total Knee Prostheses A Randomized Clinical Trial [J].
Chaudhary, R. ;
Beaupre, L. A. ;
Johnston, D. W. C. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (12) :2579-2586
[9]   Quantitative gait analysis after bilateral total knee arthroplasty with two different systems within each subject [J].
deQuervain, IAK ;
Stussi, E ;
Muller, R ;
Drobny, T ;
Munzinger, U ;
Gschwend, N .
JOURNAL OF ARTHROPLASTY, 1997, 12 (02) :168-179
[10]  
DORR LD, 1988, CLIN ORTHOP RELAT R, V236, P36