Validation and comparison of two multiplex technologies, Luminex® and Mesoscale Discovery, for human cytokine profiling

被引:204
作者
Chowdhury, Ferdousi [1 ]
Williams, Anthony [1 ]
Johnson, Peter [1 ]
机构
[1] Univ Southampton, Southampton Gen Hosp, CRUK Clin Ctr, Canc Sci Div, Southampton SO16 6YD, Hants, England
关键词
Multiplex; Cytokine; Validation; FLOW-CYTOMETRIC ASSAY; BEAD ARRAY ASSAYS; PERFORMANCE EVALUATION; CULTURE SUPERNATANTS; ACTIVATION MARKERS; TH1/TH2; CYTOKINES; HUMAN PLASMA; HUMAN SERUM; IMMUNOASSAYS; ANTIBODIES;
D O I
10.1016/j.jim.2008.10.002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Biomarker research has rapidly expanded over recent years aided by the progressive development of research tools, in particular the different multiplex technologies allowing simultaneous measurement of multiple analytes. It is foreseeable that such technology will have an integral role in clinical studies for establishing biomarker profiles of disease status, but validation of the tools is essential to confirm the reliability of their application. More comparable studies between multiplex platforms are required to enable users to determine which of these are best for a particular clinical study, as different platforms will have varying levels of performance for the validation parameters. Comparison of two multiplex platforms, the Luminex (R) and the Mesoscale Discovery, has been performed to determine their performance for the validation parameters of sensitivity, precision and accuracy for the cytokines IL-2, IL-4, IL-8, IL-10, IL-12, IFN gamma and TNF alpha. When measuring high concentrations both platforms show good accuracy (within +/-25% recovery) with all cytokines except IL-12 for the MSD. At low concentrations, +/-25% recovery was seen with all cytokines except IL-2 and 118 for the Luminex and IL-2 and IL-12 for the MSD. Although quantitative differences are found, relative differences are comparable, and consequently both platforms have been shown to be suitable for analyzing trends in multiple cytokine profiles, with the Luminex having better precision and the Mesoscale Discovery having greater sensitivity. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:55 / 64
页数:10
相关论文
共 32 条
  • [1] [Anonymous], 2000, KUBY IMMUNOLOGY
  • [2] Variables that affect assays for plasma cytokines and soluble activation markers
    Aziz, N
    Nishanian, P
    Mitsuyasu, R
    Detels, R
    Fahey, JL
    [J]. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 1999, 6 (01) : 89 - 95
  • [3] Antibodies to tumour necrosis factor α as treatment for Crohn's disease
    Bell, S
    Kamm, MA
    [J]. LANCET, 2000, 355 (9207) : 858 - 860
  • [4] Interferon-β treatment for multiple sclerosis
    Bermel, Robert A.
    Rudick, Richard A.
    [J]. NEUROTHERAPEUTICS, 2007, 4 (04) : 633 - 646
  • [5] Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay
    Carson, RT
    Vignali, DAA
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1999, 227 (1-2) : 41 - 52
  • [6] Biomarker method validation in anticancer drug development
    Cummings, J.
    Ward, T. H.
    Greystoke, A.
    Ranson, M.
    Dive, C.
    [J]. BRITISH JOURNAL OF PHARMACOLOGY, 2008, 153 (04) : 646 - 656
  • [7] Simultaneous detection of 15 human cytokines in a single sample of stimulated peripheral blood mononuclear cells
    de Jager, W
    te Velthuis, H
    Prakken, BJ
    Kuis, W
    Rijkers, GT
    [J]. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2003, 10 (01) : 133 - 139
  • [8] Recommendations for the bioanalytical method validation of ligand-binding assays to support pharmacokinetic assessments of macromolecules
    DeSilva, B
    Smith, W
    Weiner, R
    Kelley, M
    Smolec, JM
    Lee, B
    Khan, M
    Tacey, R
    Hill, H
    Celniker, A
    [J]. PHARMACEUTICAL RESEARCH, 2003, 20 (11) : 1885 - 1900
  • [9] Validation and comparison of luminex multiplex cytokine analysis kits with ELISA: Determinations of a panel of nine cytokines in clinical sample culture supernatants
    duPont, NC
    Wang, KH
    Wadhwa, PD
    Culhane, JF
    Nelson, EL
    [J]. JOURNAL OF REPRODUCTIVE IMMUNOLOGY, 2005, 66 (02) : 175 - 191
  • [10] Multiplex bead array assays: Performance evaluation and comparison of sensitivity to ELISA
    Elshal, MF
    McCoy, JP
    [J]. METHODS, 2006, 38 (04) : 317 - 323