SARAL/AltiKa Absolute Calibration from the Multi-Mission Corsica Facilities

被引:17
作者
Bonnefond, Pascal [1 ]
Exertier, Pierre [1 ]
Laurain, Olivier [1 ]
Guillot, Amandine [2 ]
Picot, Nicolas [2 ]
Cancet, Mathilde [3 ]
Lyard, Florent [4 ]
机构
[1] Geoazur, Observ Cote Azur, F-06560 Valbonne, France
[2] Ctr Natl Etud Spatiales, F-31055 Toulouse, France
[3] NOVELTIS, Labege, France
[4] Lab Etud Geophys & Oceanog Spatiales, Toulouse, France
关键词
Altimeter calibration; GPS; tide gauges; MICROWAVE RADIOMETER; JASON-1; ALTIMETERS; GPS; TOPEX/POSEIDON; VALIDATION; TOPEX;
D O I
10.1080/01490419.2015.1029656
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The geodetic Corsica site was set up in 1998 in order to perform altimeter calibration of the TOPEX/Poseidon (T/P) mission and subsequently, Jason-1 and OSTM/Jason-2. The scope of the site was widened in 2005 in order to undertake the calibration of the Envisat mission and most recently of SARAL/AltiKa. Here we present the first results from the latter mission using both indirect and direct calibration/validation approaches. The indirect approach utilizes a coastal tide gauge and, as a consequence, the altimeter derived sea surface height (SSH) needs to be corrected for the geoid slope. The direct approach utilizes a novel GPS-based system deployed offshore under the satellite ground track that permits a direct comparison with the altimeter derived SSH. The advantages and disadvantages of both systems (GPS-based and tide gauges) and methods (direct or indirect) will be described and discussed. Our results for O/IGD-R data show a very good consistency for these three kinds of products: their derived absolute SSH biases are consistent within 17mm and their associated standard deviation ranges from 31 to 35mm. The AltiKa absolute SSH bias derived from GPS-zodiac measurement using the direct method is -54 +/- 10mm based on the first 13 cycles.
引用
收藏
页码:171 / 192
页数:22
相关论文
共 36 条
[1]  
[Anonymous], 2009, RA 2 PRODUCTS SPECIF, V14
[2]  
[Anonymous], 2008, OCEAN WAVES
[3]  
Aviso, 2014, SARAL VERSION T PATC
[4]  
Bar-Sever Y., 2008, ION GNSS 2008 M SAV
[5]  
Bindoff N., 2007, THE PHYSICAL SCIENCE, P386
[6]   Absolute Calibration of Jason-1 and TOPEX/Poseidon Altimeters in Corsica [J].
Bonnefond, P. ;
Exertier, P. ;
Laurain, O. ;
Menard, Y. ;
Orsoni, A. ;
Jan, G. ;
Jeansou, E. .
MARINE GEODESY, 2003, 26 (3-4) :261-284
[7]   Leveling the Sea Surface Using a GPS-Catamaran [J].
Bonnefond, P. ;
Exertier, P. ;
Laurain, O. ;
Menard, Y. ;
Orsoni, A. ;
Jeansou, E. ;
Haines, B. J. ;
Kubitschek, D. G. ;
Born, G. .
MARINE GEODESY, 2003, 26 (3-4) :319-334
[8]   GPS-based sea level measurements to help the characterization of land contamination in coastal areas [J].
Bonnefond, P. ;
Exertier, P. ;
Laurain, O. ;
Thibaut, P. ;
Mercier, F. .
ADVANCES IN SPACE RESEARCH, 2013, 51 (08) :1383-1399
[9]   Satellite altimetry from a short-arc orbit technique: Application to the Mediterranean [J].
Bonnefond, P ;
Exertier, P ;
Schaeffer, P ;
Bruinsma, S ;
Barlier, F .
JOURNAL OF GEOPHYSICAL RESEARCH-OCEANS, 1995, 100 (C12) :25365-25382
[10]  
Bonnefond P., 2011, SITU CALIBRATION VAL, P259, DOI 10.1007/978-3-642-12796-0_11